journal article·2016-09

A New Methodology of Design Fires for Train Carriages Based on Exponential Curve Method

Ying Zhen Li, Haukur Ingason

Fire Technology· Volume 52· Issue 5
Publisher page

Abstract

Design fires have great influences on the fire safety concepts and safety measures, and are the basis for any assessment and calculation in tunnel fire safety design. A new methodology of design fires for individual train carriages is proposed based on the exponential design fire curve method and state-of-the-art fire research. The three key parameters required for construction of a design fire are the maximum heat release rate, time to maximum heat release rate, and energy content. An overview of the full scale train carriage fire tests is given and the results show that the maximum heat release rate is in a range of 7 MW to 77 MW and the time to reach the maximum heat release rate varies from 7 min to 118 min. The method could be employed to one single train carriage or several carriages, and alternatively one carriage could be divided into several individual sections. To illustrate the use of the methodology, several engineering applications are presented, including design fires for a metro train carriage with a maximum heat release rate of 77 MW, a double-deck railway train carriage with a maximum heat release rate of 60 MW and a tram carriage with a maximum heat release rate of 28 MW. The main objective is to provide practicing engineers with a flexible and reliable methodology to make design fires for individual train carriages in performance-based tunnel fire safety design.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire dynamics and safety research · Evacuation and Crowd Dynamics · Fire Detection and Safety Systems

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (28)

Show source-provided references
1. Ingason H, Li YZ, Lönnermark A (2015) Tunnel fire dynamics. Springer, New York10.1007/978-1-4939-2199-7 ↗
2. Guillaume E, Camillo A, Rogaume T (2014) Application and limitations of a method based on pyrolysis models to simulate railway rolling stock fire scenarios. Fire Technol 50:317–34810.1007/s10694-013-0379-9 ↗
3. Thematic Network on Fires in Tunnels (FIT)—Technical Report Part 1—Design Fire Scenarios (2001–2004). European Commission under the 5th Framework Program
4. Peacock R, Reneke P, Jones W, Bukowski R (1995) Concept for fire protection of passenger rail transportation vehicles:pas, present and future. Fire Mater 19:71-8710.1002/fam.810190205 ↗
5. Railway application—Fire protection on railway vehicle—Part 2: Requirement for fire behaviour of materials and components (2013). CEN/CENELEC/TC
6. Standard for Fixed Guideway Transit and Passenger Rail Systems (2003) 2003 edn. National Fire Protection Association
7. Kennedy WD, Ray RE, Quinan JW (1998) A short history of train fire heat release calculations. Paper presented at the annual meeting American Society of Heating, Refrigeration, and Air conditioning Engineers, Toronto, Canada
8. Lacroix D (1997) New French recommendations for fire ventilation in road tunnels. In: 9th international conference on aerodynamics and ventilation of vehicle tunnels, Aosta Valley, Italy, 6–8 October 1997
9. Ingason H (1995) Design fires in tunnels. In: Conference proceedings of Asiaflam 95, Hong Kong, 15–16 March 1995. Interscience Communications Ltd., pp 77–86
10. Fires in Transport Tunnels: Report on Full-Scale Tests (1995) Studiensgesellschaft Stahlanwendung e. V., Düsseldorf, Germany
11. Ingason H (2007) Model scale railcar fire tests. Fire Saf J 42(4):271–28210.1016/j.firesaf.2006.11.004 ↗
12. Steinert C (1994) Smoke and heat production in tunnel fires. In: The international conference on fires in tunnels, Borås, Sweden, 10–11 October 1994. SP Swedish National Testing and Research Institute, pp 123–137
13. Ingason H, Gustavsson S, Dahlberg M (1994) Heat release rate measurements in tunnel fires. SP Swedish National Testing and Research Institute, Borås
14. Barber C, Gardiner A, Law M (1994) Structural fire design of the Øresund tunnel. In: Ivarson E (ed) Proceedings of the international conference on fires in tunnels, Borås, Sweden, 10–11 October 1994. SP Swedish National Testing and Research Institute, pp 313–332
15. Hadjisophocleous G, Lee DH, Park WH (2012) Full-scale experiments for heat release rate measurements of railcar fires. In: International symposium on tunnel safety and security (ISTSS), New York, 2012. SP Technical Research Institute of Sweden, pp 457–466
16. Lönnermark A, Lindström J, Li YZ, Claesson A, Kumm M, Ingason H (2012) Full-scale fire tests with a commuter train in a tunnel. SP Report 2012:05. SP Technical Research Institute of Sweden, Borås, Sweden
17. Li YZ, Ingason H, Lönnermark A (2013) Correlations between different scales of metro carriage fire tests. SP Report 2013:13. SP Technical Research Institute of Sweden, Borås
18. Li YZ, Ingason H, Lönnermark A (2014) Fire development in different scales of train carriages. In: 11th international symposium on fire safety science, New Zealand10.3801/IAFSS.FSS.11-302 ↗
19. Ingason H (2009) Design fire curves in tunnels. Fire Saf J 44(2):259–26510.1016/j.firesaf.2008.06.009 ↗
20. Ingason H (2006) Design fire in tunnels. In: Safe & reliable tunnels innovative European achievements, second international symposium, Lausanne, 2006
21. Ingason H (2005) Fire development in large tunnel fires. In: 8th international symposium on fire safety science, Beijing, China, 18–23 September 2005. International Association for Fire Safety Science (IAFSS), pp 1497–150810.3801/IAFSS.FSS.8-1497 ↗
22. Bowditch PA, Sargeant AJ, Leonard JE, Macindoe L (2006) Window and glazing exposure to laboratory-simulated bushfires. CMIT Doc 2006-205. Bushfire CRC, Melbounre, Australia
23. Harada K, Enomoto A, Uede K, Wakamatsu T (2002) An experimental study on glass cracking and fallout by radiant heat exposure. In: 6th international symposium on fire safety science, London, 3–7 March 2000. International Association for Fire Safety Science (IAFSS), pp 1063–1074
24. Mowrer FW (1998) Window Breakage Induced by Exterior Fires. NISTGCR-98-751. National Institute of Standards and Technology, Gaithersburg, MD, USA
25. Strege S. LBY, Beyler C. (2003) Fire Induced Failure of Polycarbonate Windows in Railcars. Proceedings of the 8th International Fire and Materials conference, Interscience Communications,8 January 2003, pp 269–278
26. Kumm M (2010) Carried Fire Load in Mass Transport Systems—a study of occurrence, allocation and fire behavior of bags and luggage in metro and commuter trains in Stockholm. SiST 2010:04. Mälardalen University, Västerås, Sweden
27. Ingason H, Kumm M, Nilsson D, Lönnermark A, Claesson A, Li YZ, Fridolf K, Åkerstedt R, Nyman H, Dittmer T, Forsén R, Janzon B, Meyer G, Bryntse A, Carlberg T, Newlove-Eriksson L, Palm A (2012) The METRO project—final report. Report 2012:8. Mälardalen University, Västerås, Sweden
28. Nelson HE (1990) FPETOOL: fire protection engineering tools for hazard estimation. NISTIR 4380. National Institute of Standards and Technology, Gaithersburg10.6028/NIST.IR.4380 ↗