journal article·2013-04

Assessment Methods of Fire Damages in Concrete Tunnel Linings

Roberto Felicetti

Fire Technology· Volume 49· Issue 2
Publisher page

Abstract

The assessment of fire damage in concrete structures is a complex but intriguing task involving different areas of expertise, from Material Science to Structural Design, from Non-Destructive Testing to Fire Engineering. The problem grows to be even more challenging in the case of tunnels, as a consequence of the high fire severity and the operational difficulties implied by this type of infrastructure, but also because of the pressing time restrictions due to the high cost of traffic disruption during the assessment and repair works. A general overview on this subject is given in the paper, pointing out the different scales of observation, the relevant clues to be analysed at each scale and their appropriate inspection tools. These latter comprise a wide range of investigation techniques of different reliability and cost, but not many of them turn out to be viable and convenient to tackle the problem in question. In this perspective, some innovative assessment methods have been developed in recent years, having in common the ability to reveal the layered structure of fire damaged concrete, the relatively fast and easy implementation and the immediate availability of the results. A brief account on the features and the limitations of these methods is given also, as a tentative to trace some directions for future advances in this important and still open issue.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire effects on concrete materials · Structural Response to Dynamic Loads · Geophysical Methods and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (45)

Show source-provided references
1. FIT—European Thematic Network Fire in Tunnels (2005) Technical report Part 1 ‘Design fire scenarios’. http://www.etnfit.net/ . Accessed 20 November 2010
2. Abraham O, Dérobert X (2003) Non-destructive testing of fired tunnel walls: the Mont-Blanc Tunnel case study. NDT&E Int 36:411–41810.1016/S0963-8695(03)00034-3 ↗
3. Ulm FJ, Acker P, Lévy M (1999) The “Chunnel” fire. II: analysis of concrete damage. J Eng Mech 125(3):283–28910.1061/(ASCE)0733-9399(1999)125:3(283) ↗
4. Karray M, Lefebvre G, Faure RM (2004) Results of surface waves testing in the investigation of the Mont-Blanc tunnel after the 1999 fire. In: da Fonseca AV, Mayne PW (eds) Proc ISC-2 Geotech & Geophys Site Charact. Millpress, Rotterdam, pp 1481–1487
5. Pichler C, Lackner R, Mang HA (2006) Safety assessment of concrete tunnel linings under fire load. J Struct Eng 132:961–96910.1061/(ASCE)0733-9445(2006)132:6(961) ↗
6. International Tunnelling Association—WG 6 Maintenance and Repair (2004) Guidelines for structural fire resistance for road tunnels. http://www.ita-aites.org/index.php?id=28&L=0 . Accessed 21 November 2010
7. Leitner A (2001) The fire catastrophe in the Tauern Tunnel: experience and conclusions for the Austrian guidelines. Tunn Undergr Space Technol 16:217–22310.1016/S0886-7798(01)00042-6 ↗
8. Henke A, Gagliardi M (2004) The 2001 Gotthard road tunnel fire. Tunn Manag Int 7(1):33–39
9. CIB W14 report (1990) Repairability of fire damaged structures. In: Drysdale DD, Schneider U (eds) Special Issue Fire Saf J 16:251–336
10. Concrete Society (2008) Assessment and repair of fire damaged concrete structures. Technical Report 68
11. Beard A, Carvel R (eds) (2005) The handbook of tunnel fire safety. Thomas Telford, London10.1680/hotfs.31685 ↗
12. Laboratoire Central des Ponts et Chaussées (2005) Présentation des techniques de diagnostic de l’etat d’un béton soumis à un incendie. Report ME 62 (in French)
13. Bungey JH (1996) The testing of concrete in structures. Blackey, Glasgow
14. Naik TR, Malhotra VM, Popovics JS (2004) The ultrasonic pulse velocity method. In: Malhotra VM, Carino NJ (eds) CRC handbook on nondestructive testing of concrete. CRC Press LLC, Boca Raton, FL
15. Aggelis DG, Shiotani T, Polyzos D (2009) Characterization of surface crack depth and repair evaluation using Rayleigh waves. Cem Concr Compos 31:77–8310.1016/j.cemconcomp.2008.09.008 ↗
16. Davis AG, Lim MK, Germann Petersen C (2005) Rapid and economical evaluation of concrete tunnel linings with impulse response and impulse radar non-destructive methods. NDT&E Int 38(3):181–18610.1016/j.ndteint.2004.03.011 ↗
17. Felicetti R (2010) Assessment of an industrial pavement via the impact acoustics method. Eur J Environ Civ Eng 14(4):427–43910.1080/19648189.2010.9693235 ↗
18. Krause M, Bärmann M, Frielinghaus R et al (1997) Comparison of pulse-echo methods for testing concrete. NDT&E Int 30(4):195–20410.1016/S0963-8695(96)00056-4 ↗
19. RILEM (1985) Properties of materials at high temperatures: concrete. In: Schneider U (ed) Dep Civ Eng Univ Kassel, Germany
20. Felicetti R, Gambarova PG (2008) Expertise and assessment of materials and structures after fire. In: FIB Task Group 4.3: Fire design of concrete structures—structural behaviour and assessment. Fib Bull 46:63–114
21. dos Santos JR, Branco FA, de Brito J (2002) Assessment of concrete structures subjected to fire—the FB test. Mag Concr Res 54(3):203–20810.1680/macr.2002.54.3.203 ↗
22. Benedetti A, Mangoni E (2005) Damage assessment in actual fire situations by means of non-destructive techniques and concrete tests. In: Gambarova P, Felicetti R, Meda A, Riva P (eds) Proc Int Workshop Fire Design of Concrete Structures: what Now? What Next?—fib Task Group 4.3, Starrylink, Bergamo, pp 231–239
23. Annerel E, Taerwe L (2008) Approaches for the assessment of the residual strength of concrete exposed to fire. In: Alexander MG, Beushausen H, Dehn F, Moyo P (eds) Proc 2nd Int Conf Conc Repair, Rehabil Retrofit (ICCRRR08). Taylor & Francis, UK, pp 245–246
24. Short N, Purkiss J, Guise S (2001) Assessment of fire damaged concrete using colour image analysis. Constr Build Mater 15:9–1510.1016/S0950-0618(00)00065-9 ↗
25. Short N, Purkiss J, Guise S (2002) Assessment of fire-damaged concrete using crack density measurements. Struct Concr 3(3):710.1680/stco.2002.3.3.137 ↗
26. Dilek U (2007) Assessment of fire damage to a reinforced concrete structure during construction. ASCE J Perform Constr Facil 21(4):257–26310.1061/(ASCE)0887-3828(2007)21:4(257) ↗
27. ASTM C856 (2004) Standard practice for petrographic examination of hardened concrete. ASTM Int, Philadelphia
28. Ingham JP (2009) Application of petrographic examination techniques to the assessment of fire-damaged concrete and masonry structures. Mat Charact 60:700–70910.1016/j.matchar.2008.11.003 ↗
29. Felicetti R (2006) The drilling resistance test for the assessment of fire damaged concrete. J Cem Concr Compos 28:321–32910.1016/j.cemconcomp.2006.02.009 ↗
30. Felicetti R (2009) Combined while-drilling techniques for the assessment of the fire damaged concrete cover. Int Conf Appl Struct Fire Eng, Prague, pp 208–215. http://eurofiredesign.fsv.cvut.cz/Proceedings/4th_session.pdf
31. Al Wardany R (2005) Caractérisation non destructive des structures en béton au moyen des ondes dispersives de Rayleigh et de Lamb, PhD dissertation, University of Sherbrooke (in French)
32. Piwakowski B, Safinowski P (2009) Non-destructive non-contact air-coupled concrete evaluation by an ultrasound automated device, In: Abraham O, Dérobert X (eds) Proc 7th Int Symp Nondestruct Test Civil Eng—NDT-CE’09, Nantes (France), pp 603–608 www.ndt.net/article/ndtce2009/papers/36.pdf
33. Felicetti R (2011) Assessment of the deteriorated concrete cover by combined while-drilling techniques. ASCE J Infrastruct Syst (in publication)10.1061/(ASCE)IS.1943-555X.0000049 ↗
34. Colombo M, Felicetti R (2007) New NDT techniques for the assessment of fire-damaged concrete structures. Fire Saf J 42:461–47210.1016/j.firesaf.2006.09.002 ↗
35. Felicetti R (2011) Assessment of fire damaged concrete via the Hammer-Drill Pulse Transmission technique. In: Büyüköztürk O, Taşdemir MA, Güneş O, Akkaya Y (eds) Proc Int Symp Non-Destruct Test Mat Struct (NDTMS 2011). Springer, Istanbul
36. Felicetti R (2010) Analysis of sorted powder samples for the assessment of deteriorated concrete, In: Castro-Borges P, Moreno EI, Sakai K, Gjorv O, Banthia N (eds) Proc 6th Int Conf Concr under Severe Condit Environ Load (CONSEC’10). CRC Press, pp 1123–1129
37. Felicetti R (2005) Digital-camera colorimetry for the assessment of fire-damaged concrete. In: Gambarova P, Felicetti R, Meda A, Riva P (eds) Proc Int Workshop Fire Design of Concrete Structures: what Now? What Next?—fib Task Group 4.3. Starrylink, Bergamo, pp 211–220
38. Handoo SK, Agarwal S, Agarwal SK (2002) Physicochemical, mineralogical, and morphological characteristics of concrete exposed to elevated temperatures. Cem Concr Res 32:1009–101810.1016/S0008-8846(01)00736-0 ↗
39. Alarcon-Ruiz L, Platret G, Massieu E, Ehrlacher A (2005) The use of thermal analysis in assessing the effect of temperature on a cement paste. Cem Concr Res 35:609–61310.1016/j.cemconres.2004.06.015 ↗
40. Poon C-S, Azhar S, Anson M, Wong Y-L (2001) Strength and durability recovery of fire damaged concrete after post-fire-curing. Cem Concr Res 31:1307–131810.1016/S0008-8846(01)00582-8 ↗
41. Greenhalgh SA, King DW (1981) Curved raypath interpretation of seismic refraction data. Geophys Prospect 29:853–88210.1111/j.1365-2478.1981.tb01031.x ↗
42. Benedetti A (1998) On the ultrasonic pulse propagation into fire damaged concrete. ACI Struct J 96(3):257–271
43. Qixian L, Bungey JH (1996) Using compression wave ultrasonic transducers to measure the velocity of surface waves and hence determine dynamic modulus of elasticity for concrete. Constr Build Mater 10(4):237–24210.1016/0950-0618(96)00003-7 ↗
44. Kurz JH, Grosse CU, Reinhardt H-W (2005) Strategies for reliable automatic onset time picking of acoustic emissions and of ultrasound signals in concrete. Ultrasonics 43:538–54610.1016/j.ultras.2004.12.005 ↗
45. Breysse D, Soutsos M, Felicetti R et al (2009) How to improve the quality of concrete assessment by combining several NDT measurements. In: Abraham O, Dérobert X (eds) Proc 7th Int Symp Nondestruct Test Civil Eng—NDT-CE’09, Nantes (France), pp 399–406. www.ndt.net/article/ndtce2009/papers/149.pdf