Full-Scale Experiments of Fire Control and Suppression in Enclosed Car Parks: A Comparison Between Sprinkler and Water-Mist Systems
Source abstract
Abstract
Recent efforts to investigate car-park fires and understand the related mechanisms have fostered the need for analyses of suppression performance against this type of fire scenario. This work aims at providing an insight into the ability of sprinklers and water-mist systems to control and extinguish a fire within an enclosed car park through a series of real-scale experiments. Three cars were employed in each test: the central one was ignited by a heptane pool fire and the adjacent ones served as targets. Two configurations were explored: in the first one, a nozzle was placed directly at the vertical axis of the ignition source, whereas the ignition source was located between the area coverage of four nozzles in the second one. The sprinkler system mainly served as a reference; two values of discharge density were evaluated for water mist at high operative pressure and a biodegradable surfactant was also tested against the most challenging configuration. A quantitative analysis of free-burn and discharge phases by temperature measurements was coupled with radiant heat-flux measurements and an assessment of post-fire damage. Sprinkler and water-mist systems were capable of containing the fire spread and thermally controlling the fire, thus preventing structural damage. The water mist’s ability to overpower the plume and reach the burning surfaces proved more effective than that of sprinklers, especially as no nozzles were located right above the ignition surface. The higher discharge density showed better capability of preventing re-ignition phenomena and suppression was attained in both the investigated configurations, which suggests that a certain amount of flux is also needed to achieve flame cooling. The additive had promising impact on suppression performance; however, more tests are required to specifically explore its ability to enhance thermal control.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire dynamics and safety research · Combustion and Detonation Processes · Fire Detection and Safety Systems
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (57)
Show source-provided references
1. Hill J (2005) Car park designers’ handbook. Thomas Telford Publishing, London10.1680/cpdh.34389 ↗
2. Shipp M, Fraser-Mitchell J, Chitty R, Cullinan R, Crowder D, Clark P (2009) Fire spread in car parks. Final research report BD 2552. Building Research Establishment, Watford
3. Richardson K (2014) Electrical fault caused airport car park blaze. Edinburgh Evening News. Johnston Press, London
4. Eurofeu Sprinkler Section (2009) Position paper on the fire protection of car parks. Eurofeu Sprinkler Section, Würzburg
5. Merci B (2013) Special issue fire safety journal on car park fire safety: preface. Fire Saf J 57:210.1016/j.firesaf.2011.06.003 ↗
6. Chow WK, Fung WY (1995) Survey on the indoor environment of enclosed car parks in Hong Kong. Tunn Undergr Space Technol 10:247–25510.1016/0886-7798(95)00011-M ↗
7. Chow WK (1996) Simulation of carbon monoxide level in enclosed car parks using an air flow network program. Tunn Undergr Space Technol 11:237–24010.1016/0886-7798(96)00011-9 ↗
8. Chow WK, Wong LT, Fung WY (1996) Field study on the indoor thermal environment and carbon monoxide levels in a large underground car park. Tunn Undergr Space Technol 11:333–34310.1016/0886-7798(96)00025-9 ↗
9. Chan MY, Burnett J, Chow WK (1998) Energy use for ventilation systems in underground car parks. Build Environ 33:303–31410.1016/S0360-1323(97)00075-9 ↗
10. Chow WK (1998) On safety systems for underground car parks. Tunn Undergr Space Technol 13:281–28710.1016/S0886-7798(98)00060-1 ↗
11. Viegas JC (2010) The use of impulse ventilation for smoke control in underground car parks. Tunn Undergr Space Technol 25:42–5310.1016/j.tust.2009.08.003 ↗
12. Zhang XG, Guo YC, Chan CK, Lin WY (2007) Numerical simulations on fire spread and smoke movement in an underground car park. Build Environ 42:3466–347510.1016/j.buildenv.2006.11.002 ↗
13. Lin Z, Chow TT, Tsang CF, Fong KF, Chan LS, Shum WS (2008) Effect of ventilation system on smoke and fire spread in a public transport interchange. Fire Technol 44:463–47910.1007/s10694-007-0037-1 ↗
14. Joyeux D (1997) Natural fires in closed car parks—Car fire tests. CTICM Report no. INC-96/294d-DJ/NB. Centre Technique Industriel Construction Métallique, Maizières-les-Metz
15. Schleich JB, Cajot L-G, Pierre M, Brasseur M, Franssen J-M, Kruppa J, Joyeux D, Twilt L, Van Oerle J, Aurtenetxe G (1999) Development of design rules for steel structures subjected to natural fires in closed car parks. Report EUR 18867. European Coal and Steel Community, Brussels
16. Zhao B, Kruppa J (2004) Structural behaviour of an open car park under real fire scenarios. Fire Mater 28:269–28010.1002/fam.867 ↗
17. Tilley N, Deckers X, Merci B (2012) CFD study of relation between ventilation velocity and smoke backlayering distance in large closed car parks. Fire Saf J 48:11–2010.1016/j.firesaf.2011.12.005 ↗
18. Horváth I, van Beeck J, Merci B (2013) Full-scale and reduced-scale tests on smoke movement in case of car park fire. Fire Saf J 57:35–4310.1016/j.firesaf.2012.10.009 ↗
19. Deckers X, Haga S, Sette B, Merci B (2013) Smoke control in case of fire in a large car park: Full-scale experiments. Fire Saf J 57:11–2110.1016/j.firesaf.2012.10.017 ↗
20. Deckers X, Haga S, Tilley N, Merci B (2013) Smoke control in case of fire in a large car park: CFD simulations of full-scale configurations. Fire Saf J 57:22–3410.1016/j.firesaf.2012.02.005 ↗
21. Fang C, Izzuddin BA, Obiala R, Elghazouli AY, Nethercot DA (2012) Robustness of multi-storey car parks under vehicle fire. J Constr Steel Res 75:72–8410.1016/j.jcsr.2012.03.004 ↗
22. Fang C, Izzuddin BA, Elghazouli AY, Nethercot DA (2013) Robustness of multi-storey car parks under localized fire—Towards practical design recommendations. J Constr Steel Res 90:193–20810.1016/j.jcsr.2013.08.004 ↗
23. Fang C, Izzuddin BA, Elghazouli AY, Nethercot DA (2013) Simplified energy-based robustness assessment for steel-composite car parks under vehicle fire. Eng Struct 49:719–73210.1016/j.engstruct.2012.12.036 ↗
24. Annerel E, Taerwe L, Merci B, Jansen D, Bamonte P, Felicetti R (2013) Thermo-mechanical analysis of an underground car park structure exposed to fire. Fire Saf J 57:96–106.10.1016/j.firesaf.2012.07.006 ↗
25. van der Heijden MGM, Loomans MGLC, Lemaire AD, Hensen JLM (2013) Fire safety assessment of semi-open car parks based on validated CFD simulations. Build Simul 6:385–39410.1007/s12273-013-0118-7 ↗
26. Van den Schoor F, Middha P, Van den Bulck E (2013) Risk analysis of LPG (liquefied petroleum gas) vehicles in enclosed car parks. Fire Saf J 57:58–6810.1016/j.firesaf.2012.10.026 ↗
27. Merci B, Shipp M (2013) Smoke and heat control for fires in large car parks: Lessons learnt from research? Fire Saf J 57:3–1010.1016/j.firesaf.2012.05.001 ↗
28. VdS (2015) Wassernebel-Sprinkleranlagen und Wassernebel-Löschanlagen (Hochdruck-Systeme), Planung und Einbau (Water mist-sprinkler systems and water-mist extinguishing systems—High-pressure systems, Planning and installation). VdS 3188. VdS Schadenverhütung, Cologne
29. European Committee for Standardization (2009) Fixed firefighting systems—Automatic sprinkler systems—Design, installation and maintenance. EN 12845:2004 + A2:2009. CEN-CENELEC, Brussels
30. Mangs J, Keski-Rahkonen O (1994) Characterization of the fire behaviour of a burning passenger car. Part I: Car Fire Experiments. Fire Saf J 23:17–3510.1016/0379-7112(94)90059-0 ↗
31. Tohir MZM, Spearpoint M (2013) Distribution analysis of the fire severity characteristics of single passenger road vehicles using heat release rate data. Fire Sci Rev 2:510.1186/2193-0414-2-5 ↗
32. Spearpoint MJ, Mohd Tohir MZ, Abu AK, Xie P (2015) Fire load energy densities for risk-based design of car parking buildings. Case Stud Fire Saf 3:44–5010.1016/j.csfs.2015.04.001 ↗
33. Ren N, Blum A, Do C, Marshall AW (2009) Atomization and dispersion measurements in fire sprinkler sprays. Atom Sprays 19:1125–113610.1615/AtomizSpr.v19.i12.30 ↗
34. Santangelo PE (2010) Characterization of high-pressure water-mist sprays: Experimental analysis of droplet size and dispersion. Exp Therm Fluid Sci 34:1353–136610.1016/j.expthermflusci.2010.06.008 ↗
35. [35] Santangelo PE (2012) Experiments and modeling of discharge characteristics in water-mist sprays generated by pressure-swirl atomizers. J Therm Sci 21:539–54810.1007/s11630-012-0579-5 ↗
36. Santangelo PE, Tartarini P, Valdiserri P (2011) Experimental parametric analysis of water-mist sprays: An investigation on coalescence and initial dispersion. In: Proceedings of ASME 2011 international mechanical engineering congress and exposition (IMECE 2011), vol 6. Denver, CO, pp 1167–117410.1115/IMECE2011-63846 ↗
37. Heskestad G (1972) Proposal for studying interaction of water sprays with plume in sprinkler optimization program. FMRC Interoffice Correspondence. FM Global, Norwood
38. Lefebvre AH (1989) Atomization and sprays. Hemisphere, Washington
39. Lawson JR, Walton WD, Evans DD (1988) Measurement of droplet size in sprinkler sprays. NBSIR 88-3715. National Bureau of Standards, Gaithersburg10.6028/NBS.IR.88-3715 ↗
40. Santangelo PE, Tartarini P, Pulvirenti B, Valdiserri P, Marshall AW (2010) Fire suppression by water-mist sprays: experimental and numerical analysis. In: Proceedings of 14th international heat transfer conference (IHTC-14), vol 5. Washington, pp 571–58010.1115/IHTC14-22634 ↗
41. Santangelo PE, Tartarini P (2012) Full-scale experiments of fire suppression in high-hazard storages: A temperature-based analysis of water-mist systems. Appl Therm Eng 45–46:99–10710.1016/j.applthermaleng.2012.04.011 ↗
42. Giffen E, Muraszew A (1953) Atomization of liquid fuels. Chapman & Hall, London
43. Rizk NK, Lefebvre AH (1985) Internal flow characteristics of simplex swirl atomizers. J Propul Power 1:193–19910.2514/3.22780 ↗
44. Scheffey JL, Forssell EW, Childs JT (2013) Evaluation of water additives for fire control and vapor mitigation. Phase I Final Report. The Fire Protection Research Foundation, Quincy
45. Stroup DW, Madrzykowski D, Bishop MJ (1998) Chapter 2: Fire fighting properties. In: Madrzykowski D, Stroup DW (eds) Demonstration of biodegradable, environmentally safe, non-toxic fire suppression liquids. NISTIR 6191. National Institute of Standards and Technology, Gaithersburg10.6028/NIST.IR.6191 ↗
46. National Fire Protection Association (2015) NFPA 750 Standard on water mist fire protection systems. NFPA, Quincy
47. Ingason H, Wickström U (2007) Measuring incident radiant heat flux using the plate thermometer. Fire Saf J 42:161–16610.1016/j.firesaf.2006.08.008 ↗
48. Haremza C, Santiago A, Simões da Silva L (2013) Design of steel and composite open car parks. Adv Steel Constr 9:350–368
49. Yule HP (1969) Computation of experimental results in activation analysis. In: DeVoe JR, LaFleur PD (eds) Modern trends in activation analysis, vol 2. National Bureau of Standards, Washington, pp 1155–1204
50. Orlandini S, Moretti G, Corticelli MA, Santangelo PE, Capra A, Rivola R, Albertson JD (2012) Evaluation of flow direction methods against field observations of overland flow dispersion. Water Resour Res 48:W1052310.1029/2012WR012067 ↗
51. Santangelo PE, Jacobs BC, Ren N, Sheffel JA, Corn ML, Marshall AW (2014) Suppression effectiveness of water-mist sprays on accelerated wood-crib fires. Fire Saf J 70:98–11110.1016/j.firesaf.2014.08.012 ↗
52. Shipp MP, Spearpoint MJ (1995) Measurements of the severity of fires involving private motor vehicles. Fire Mater 19:143–15110.1002/fam.810190307 ↗
53. Li Y, Spearpoint M (2007) Analysis of vehicle fire statistics in New Zealand parking buildings. Fire Technol 43:93–10610.1007/s10694-006-0004-2 ↗
54. Lönnermark A, Ingason H (2005) Fire spread in large industrial premises and warehouses. SP Report 2005:21. SP Swedish National Testing and Research Institute, Borås
55. Heskestad G (2002) Scaling the interaction of water sprays and flames. Fire Saf J 37:535–54810.1016/S0379-7112(02)00012-7 ↗
56. Heskestad G (2003) Extinction of gas and liquid pool fires with water sprays. Fire Saf J 38:301–31710.1016/S0379-7112(02)00085-1 ↗
57. Liu Z, Kim AK, Su JZ (2001) Examination of performance of water mist fire suppression systems under ventilation conditions. J Fire Prot Eng 11:164–19310.1106/3VE8-WWT4-C3U4-FEH9 ↗