journal article·2024-07Open access

Fire Performance of Corroded Reinforced Concrete Columns

Shashank Chandra, Umesh Kumar Sharma, Mark Green, John Gales, Pradeep Bhargava

Fire Technology· Volume 60· Issue 4

Abstract

The current guidelines for obtaining fire ratings of the reinforced concrete columns are limited to the pristine elements, which do not include the effect of corrosion. An experimental investigation was conducted to examine the effects of corrosion on the fire performance of reinforced concrete (RC) columns. Four full-scale column specimens were cast and tested in this study. Two columns were corroded by the accelerated corrosion regime for the target corrosion of 20%, while the remaining columns were the control specimens and were kept uncorroded. After the desired exposure time for the accelerated corrosion, all the columns were tested in a fire furnace under the standard ISO-834 fire. The experimental results showed that corrosion has a significant influence on the fire performance of the columns. The result shows that the fire rating of the corroded high-strength concrete (HSC) column drops considerably. However, there is a slight improvement in the behaviour of the corroded normal-strength concrete (NSC) column when subjected to fire. The effect of corrosion cracks and spalling on the fire resistance of the corroded RC columns was also noted in this study. This research will enable the design of new reinforced concrete columns for better fire performance despite age-related corrosion deterioration.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Concrete Corrosion and Durability · Fire effects on concrete materials · Structural Behavior of Reinforced Concrete

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (35)

Show source-provided references
1. Zhang W, Song X, Gu X, Li S (2012) Tensile and fatigue behavior of corroded rebars. Constr Build Mater 34:409–41710.1016/j.conbuildmat.2012.02.071 ↗
2. Suda K, Misra S, Motohashi K (1993) Corrosion products of reinforcing bars embedded in concrete. Corros Sci 35(5–8):1543–154910.1016/0010-938X(93)90382-Q ↗
3. Fang C, Lundgren K, Chen L, Zhu C (2004) Corrosion influence on bond in reinforced concrete. Cem Concr Res 34(11):2159–216710.1016/j.cemconres.2004.04.006 ↗
4. Coccia S, Imperatore S, Rinaldi Z (2016) Influence of corrosion on the bond strength of steel rebars in concrete. Mater Struct 49(1):537–55110.1617/s11527-014-0518-x ↗
5. Lundgren K (2007) Effect of corrosion on the bond between steel and concrete: an overview. Mag Concr Res 59(6):447–46110.1680/macr.2007.59.6.447 ↗
6. Rodriguez J, Ortega LM, Casal J (1997) Load carrying capacity of concrete structures with corroded reinforcement. Constr Build Mater 11(4):239–24810.1016/S0950-0618(97)00043-3 ↗
7. Rajput AS, Sharma UK (2018) Corroded reinforced concrete columns under simulated seismic loading. Eng Struct 171:453–46310.1016/j.engstruct.2018.05.097 ↗
8. Xia J, Jin WL, Li LY (2016) Performance of corroded reinforced concrete columns under the action of eccentric loads. J Mater Civ Eng 28(1):0401508710.1061/(ASCE)MT.1943-5533.0001352 ↗
9. Ou YC, Nguyen ND (2016) Influences of location of reinforcement corrosion on seismic performance of corroded reinforced concrete beams. Eng Struct 126:210–22310.1016/j.engstruct.2016.07.048 ↗
10. Liu X, Jiang H, He L (2017) Experimental investigation on seismic performance of corroded reinforced concrete moment-resisting frames. Eng Struct 153:639–65210.1016/j.engstruct.2017.10.034 ↗
11. U.S. Fire Administration (2018) Non-residential building fire trends (2007–2016), Emmitsburg
12. Kodur V (2014) Properties of concrete at elevated temperatures. International Scholarly Research Notices. https://doi.org/10.1155/2014/46851010.1155/2014/468510 ↗
13. Wu H, Lin X, Zhou A (2020) A review of mechanical properties of fibre reinforced concrete at elevated temperatures. Cem Concr Res 135:10611710.1016/j.cemconres.2020.106117 ↗
14. Cheng FP, Kodur VKR, Wang TC (2004) Stress-strain curves for high-strength concrete at elevated temperatures. J Mater Civ Eng 16(1):84–9010.1061/(ASCE)0899-1561(2004)16:1(84) ↗
15. Youssef MA, Moftah M (2007) General stress-strain relationship for concrete at elevated temperatures. Eng Struct 29(10):2618–263410.1016/j.engstruct.2007.01.002 ↗
16. Morley PD, Royles R (1983) Response of the bond in reinforced concrete to high temperatures. Mag Concr Res 35(123):67–7410.1680/macr.1983.35.123.67 ↗
17. Morley PD, Royles R (1980) The influence of high temperature on the bond in reinforced concrete. Fire Saf J 2(4):243–25510.1016/0379-7112(79)90024-9 ↗
18. IS 3809 (1979) Fire resistance test for structures
19. Shah AH, Sharma UK (2017) Fire resistance and spalling performance of confined concrete columns. Constr Build Mater 156:161–17410.1016/j.conbuildmat.2017.08.167 ↗
20. Franssen JM, Dotreppe JC (2003) Fire tests and calculation methods for circular concrete columns. Fire Technol 39(1):89–9710.1023/A:1021783311892 ↗
21. Raut NK, Kodur VKR (2011) Response of high-strength concrete columns under design fire exposure. J Struct Eng 137(1):69–7910.1061/(ASCE)ST.1943-541X.0000265 ↗
22. Rodrigues JPC, Laím L, Correia AM (2010) Behaviour of fiber reinforced concrete columns in fire. Compos Struct 92(5):1263–126810.1016/j.compstruct.2009.10.029 ↗
23. Buch SH, Sharma UK (2019) Fire resistance of eccentrically loaded reinforced concrete columns. Fire Technol 55:1517–155210.1007/s10694-019-00823-x ↗
24. EN 1992–1–2 (1992) Eurocode 2: Design of concrete structures - Part 1–2: General rules - Structural fire design
25. C. S. Standards Association of Australia. Committee BD-002, Concrete structures : AS 3600–2009
26. Yang O, Zhang B, Yan G, Chen J (2018) Bond performance between slightly corroded steel bar and concrete after exposure to high temperature. J Struct Eng 144(11):0401820910.1061/(ASCE)ST.1943-541X.0002217 ↗
27. Tariq F, Bhargava P (2021) Flexural behaviour of corroded RC beams exposed to fire. Structures, vol 33. Elsevier, Amsterdam, pp 1366–1375
28. Ba G, Miao J, Zhang W, Liu J (2019) Influence of reinforcement corrosion on fire performance of reinforced concrete beams. Constr Build Mater 213:738–74710.1016/j.conbuildmat.2019.04.065 ↗
29. IS/ISO 834–1 (1999) Fire-Resistance Tests — Elements of Building Construction: Part 1 General Requirements
30. IS 456 (2000) Plain and Reinforced Concrete - Code of Practice
31. (Reapproved:2011) A-03 (2016) Standard practice for preparing, cleaning, and evaluating corrosion test. ASTM G1–03 03:1–9. https://doi.org/10.1520/G0001-03R11.2.10.1520/G0001-03R11.2 ↗
32. I. Standard, Hardened Concrete-Methods of Test Part 5 Non-Destructive Testing Section Half-Cell Potentials of Uncoated Reinforcing Steel in Concrete, 2021
33. Ba G, Miao J, Zhang W, Liu C (2016) Influence of cracking on heat propagation in reinforced concrete structures. J Struct Eng 142(7):0401603510.1061/(ASCE)ST.1943-541X.0001483 ↗
34. Wu B, Xiong W, Wen B (2014) Thermal fields of cracked concrete members in fire. Fire Saf J 66:15–2410.1016/j.firesaf.2014.04.003 ↗
35. Takeda M, Onishi T, Nakakubo S, Fujimoto S (2009) Physical properties of iron-oxide scales on Si-containing steels at high temperature. Mater Trans 50(9):2242–224610.2320/matertrans.M2009097 ↗