Effect of Thin Intumescent Coating Type and Thickness on the Charring of Mass Timber Under Varied Heat Flux Exposure
Source abstract
Abstract
Abstract This study investigates how three types of thin intumescent coatings, applied at different Dry Film Thicknesses (DFTs), influence the charring behaviour of mass timber in fire, including the effects of varying heating conditions. Bench-scale timber samples of Cross-Laminated Timber (CLT) were tested for 60 min at a constant 25, 50, or 75 kW/m 2 incident radiant heat flux. Tests were conducted on timber samples painted with opaque coatings (solvent-based Coating A and water-based Coating B) and a transparent coating (water-based Coating C), as well as bare timber samples as a control. Three DFT thresholds were considered for each coating, spanning 0.98–2.60 mm for the opaque coatings and 0.18–0.40 mm for the transparent coating. The findings demonstrated that, although coated timber still chars, the onset of charring is significantly delayed compared to bare timber. For the opaque coatings, this was dependent on both thickness and heat flux, whereas for the transparent coating, the insulating efficacy was primarily governed by the heat flux – with its durability markedly compromised above 25 kW/m 2 . Compared to bare timber, opaque coatings A and B showed reductions in mean charring rates of up to 70%, 62%, and 56% under heat fluxes of 25, 50, and 75 kW/m 2 , respectively. In contrast, timber with transparent Coating C achieved mean charring rate reductions of up to 36%, 18%, and zero under the same heat flux conditions. The main conclusions from the study were: (1) opaque coatings are more effective than the transparent coating in reducing timber charring; (2) higher heat flux conditions reduce the effectiveness of intumescent coatings for all coating types; and (3) while increased DFT generally reduced charring of coated timber, particularly for opaque coatings A and B samples, it was insufficient to offset the effects of higher heat flux intensity in timber samples with transparent Coating C - especially at 50 and 75 kW/m 2 . Graphical Abstract
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Wood Treatment and Properties · Lignin and Wood Chemistry · Material Properties and Processing
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (62)
Show source-provided references
1. Barber D (2015) Tall timber buildings: what’s next in fire safety? Fire Technol 51(6):1279–1284. https://doi.org/10.1007/s10694-015-0497-710.1007/s10694-015-0497-7 ↗
2. Mitchell H, Kotsovinos P, Richter F, Thomson D, Barber D, Rein G (2023) Review of fire experiments in mass timber compartments: current understanding, limitations, and research gaps. Fire Mater 47(4):415–432. https://doi.org/10.1002/fam.312110.1002/fam.3121 ↗
3. Hadden RM et al (2017) Effects of exposed cross laminated timber on compartment fire dynamics. Fire Saf J 91:480–489. https://doi.org/10.1016/j.firesaf.2017.03.07410.1016/j.firesaf.2017.03.074 ↗
4. Kotsovinos P et al (2022) Fire dynamics inside a large and open-plan compartment with exposed timber ceiling and columns: codered# 01. Fire Mater. https://doi.org/10.1002/fam.304910.1002/fam.3049 ↗
5. Kotsovinos P et al (2023) Impact of ventilation on the fire dynamics of an open-plan compartment with exposed timber ceiling and columns: codered# 02. Fire Mater 47(4):569–596. https://doi.org/10.1002/fam.308210.1002/fam.3082 ↗
6. Wiesner F et al (2021) Structural capacity of one-way spanning large-scale cross-laminated timber slabs in standard and natural fires. Fire Technol 57(1):291–311. https://doi.org/10.1007/s10694-020-01003-y10.1007/s10694-020-01003-y ↗
7. International Code Council and SFPE (2022) Fire safety for very tall buildings: engineering guide. Springer
8. Buchanan A, Östman B (2022) Fire safe use of wood in buildings: global design guide. Taylor & Francis10.1201/9781003190318 ↗
9. Violette Memoir on the Charcoals of Wood, Annales de Chimie et de Physique, vol. 32, pp. 20–74, 1851. [Online]. Available: https://gallica.bnf.fr/
10. Schaffer EL (1967) Charring rate of selected woods-transverse to grain, USDA Forest Service, Forest Products Laboratory, Madison, WI, FPL 69
11. White R (1988) Charring rates of different wood species, Ph.D, University of Wisconsin-Madison, Madison, WI
12. White RH (2000) Charring rate of composite timber products, in Wood & Fire Safety (WFS 2000), pp. 353–363
13. National Construction Code (2022) Volume One - Building Code of Australia, Class 2 to 9 buildings, ed. 2023
14. Fire classification of construction products and building elements. Classification using data from fire resistance and/or smoke control tests, excluding ventilation services., BS EN 13501-2:2023, ed. (2023)
15. Arup, Fire Safe Design of Mass Timber Buildings, (2024) Accessed: September 2024. [Online]. Available: https://www.arup.com/insights/fire-safe-design-of-mass-timber-buildings/
16. Puri RG, Khanna A (2017) Intumescent coatings: A review on recent progress. J Coat Technol Res 14(1):1–20. https://doi.org/10.1007/s11998-016-9815-310.1007/s11998-016-9815-3 ↗
17. Lucherini A, Maluk C (2019) Intumescent coatings used for the fire-safe design of steel structures: A review. J Constr Steel Res 162:105712. https://doi.org/10.1016/j.jcsr.2019.10571210.1016/j.jcsr.2019.105712 ↗
18. Lucherini A, Maluk C (2019) Assessing the onset of swelling for thin intumescent coatings under a range of heating conditions. Fire Saf J 106:1–12. https://doi.org/10.1016/j.firesaf.2019.03.01410.1016/j.firesaf.2019.03.014 ↗
19. Mariappan T (2016) Recent developments of intumescent fire protection coatings for structural steel: A review. J Fire Sci 34(2):120–163. https://doi.org/10.1177/073490411562672010.1177/0734904115626720 ↗
20. a. TAP (1993) Thermal analysis of intumescent coatings. Eur Polym Paint Colour J 182(4301):122–130
21. Lucherini A (2020) Fundamentals of thin intumescent coatings for the design of fire-safe structures, ph.d., school of civil engineering. The University of Queensland, Brisbane
22. Lucherini A, Hidalgo JP, Torero JL, Maluk C (2021) Influence of heating conditions and initial thickness on the effectiveness of thin intumescent coatings. Fire Saf J 120:103078. https://doi.org/10.1016/j.firesaf.2020.10307810.1016/j.firesaf.2020.103078 ↗
23. Gillet M, Autrique L, Perez L (2007) Mathematical model for intumescent coatings growth: application to fire retardant systems evaluation. J Phys D 40(3):883. https://doi.org/10.1088/0022-3727/40/3/03010.1088/0022-3727/40/3/030 ↗
24. Li G-Q, Zhang C, Lou G-B, Wang Y-C, Wang L-L (2012) Assess the fire resistance of intumescent coatings by equivalent constant thermal resistance. Fire Technol 48:529–546. https://doi.org/10.1007/s10694-011-0243-810.1007/s10694-011-0243-8 ↗
25. Wang L, Dong Y, Zhang C, Zhang D (2015) Experimental study of heat transfer in intumescent coatings exposed to non-standard furnace curves. Fire Technol 51:627–643. https://doi.org/10.1007/s10694-015-0460-710.1007/s10694-015-0460-7 ↗
26. Yuan J (2009) Intumescent coating performance on steel structures under realistic fire conditions, ph.d., school of mechanical, aerospace and civil engineering. The University of Manchester, Manchester
27. Jimenez M, Duquesne S, Bourbigot S (2006) Intumescent fire protective coating: toward a better Understanding of their mechanism of action. Thermochimica Acta 449:1–2. https://doi.org/10.1016/j.tca.2006.07.00810.1016/j.tca.2006.07.008 ↗
28. Camino G, Costa L, Martinasso G (1989) Intumescent fire-retardant systems. Polym Degrad Stab 23(4):359–376. https://doi.org/10.1016/0141-3910(89)90058-X10.1016/0141-3910(89)90058-X ↗
29. Gerasimov N (2020) Behaviour of intumescent coatings under non-standard heating conditions, ph.d., school of engineering. The University of Edinburgh, Edinburgh
30. Ohuchi T, Miyamoto K (1996) Application of Fire Intumescent Coating to Timber, [In Japanese] presented at the Summaries of Technical Papers of Annual Meeting, Architectural Institute of Japan, September 1996
31. Karuga H, Watanabe A, Ohuchi T, Miyamoto K (2006) Fire Resistance of Transparent Fire Intumescent Coating for Wood, [In Japanese] presented at the Summaries of Technical Papers of Annual Meeting, Architectural Institute of Japan, September 2006
32. Hakkarainen T (2010) Thin thermal barriers for wood based products to improve fire resistance, VTT, Finland, Accessed: October 2024. [Online]. Available: https://sarjaweb.vtt.fi/julkaisut/muut/2009/VTT-R-07061-09.pdf
33. Lucherini A, Razzaque QS, Maluk C (2019) Exploring the fire behaviour of thin intumescent coatings used on timber. Fire Saf J 109:102887. https://doi.org/10.1016/j.firesaf.2019.10288710.1016/j.firesaf.2019.102887 ↗
34. Spyridakis S, Carrascal J, Wiesner F, Barber D, Maluk C Exploring the influence of heating conditions in the charring profile of bare timber and timber protected with a thin intumescent coating, in World Conference on Timber Engineering (WCTE (2023)), Oslo, Norway, 2023, pp. 1644–1652, doi: ), Oslo, Norway, 2023, pp. 1644–1652. https://doi.org/10.52202/069179-022110.52202/069179-0221 ↗
35. Spyridakis S, Maluk C (2024) Exploring the influence of thin intumescent coatings on the onset and rate of charring for mass timber during fire. Wood & fire safety (WFS 2024). Springer, pp 154–161. doi: https://doi.org/10.1007/978-3-031-59177-8_18.10.1007/978-3-031-59177-8_18 ↗
36. Yan L, Xu Z, Liu D (2019) Synthesis and application of novel magnesium phosphate ester flame retardants for transparent intumescent fire-retardant coatings applied on wood substrates. Prog Org Coat 129:327–337. https://doi.org/10.1016/j.porgcoat.2019.01.01310.1016/j.porgcoat.2019.01.013 ↗
37. Wang F, Zhang Z, Wang Q, Tang J (2008) Fire-retardant and smoke-suppressant performance of an intumescent waterborne amino-resin fire-retardant coating for wood. Front Forestry China 3:487–492. https://doi.org/10.1007/s11461-008-0075-y10.1007/s11461-008-0075-y ↗
38. Wakefield T, He Y, Dowling V (2009) An experimental study of solid timber external wall performance under simulated bushfire attack. Build Environ 44(10):2150–2157. https://doi.org/10.1016/j.buildenv.2009.03.00510.1016/j.buildenv.2009.03.005 ↗
39. Lai Y et al (2023) Investigating the fire-retardant efficiency of intumescent coatings on inclined timber: A study on application strategies and heat transfer mechanisms. Constr Build Mater 407:133586. https://doi.org/10.1016/j.conbuildmat.2023.13358610.1016/j.conbuildmat.2023.133586 ↗
40. Johnson L, Morrisset D, Colic A, Bisby L Comparative performance of protective coatings for mass timber structures, in World Conference on Timber Engineering (WCTE (2023)), Oslo, Norway, 2023, pp. 1788–1797, doi: ), Oslo, Norway, 2023, pp. 1788–1797. https://doi.org/10.52202/069179-023710.52202/069179-0237 ↗
41. Zheng X, He M, Li Z, Lou G, Li GQ (2024) Experimental investigation into the effect of transparent fireproof coatings on charring behavior of glued laminated timber exposed to fire. Fire Saf J. https://doi.org/10.1016/j.firesaf.2024.10427410.1016/j.firesaf.2024.104274 ↗
42. Maluk C, Bisby L, Krajcovic M, Torero JL (2019) A heat-transfer rate inducing system (H-TRIS) test method. Fire Saf J 105:307–319. https://doi.org/10.1016/j.firesaf.2016.05.00110.1016/j.firesaf.2016.05.001 ↗
43. Kidd C, Nelson C (1995) How the Schmidt-Boelter gage really works, in Proceedings of the 41st International Instrumentation Symposium, ResearchTriangle Park, : Instrument Society of America, pp. 347–368
44. Filtz J et al (2002) Improving heat fluxmeter calibration for fire testing laboratories (HFCAL), Brussels, Belgium, Report 9012453 C360W03- Document CMI/1
45. Fire tests — Calibration and use of heat flux meters Part 4: Guidance on the use of heat flux meters in fire tests, BS ISO 14934-4:2014, ed. (2014)
46. Drysdale D (2011) An introduction to fire dynamics. Wiley10.1002/9781119975465 ↗
47. Peacock RD, Reneke PA, Bukowski RW, Babrauskas V (1999) Defining flashover for fire hazard calculations. Fire Saf J 32(4):331–345. https://doi.org/10.1016/S0379-7112(98)00048-410.1016/S0379-7112(98)00048-4 ↗
48. Emberley R et al (2017) Description of small and large-scale cross laminated timber fire tests. Fire Saf J 91:327–335. https://doi.org/10.1016/j.firesaf.2017.03.02410.1016/j.firesaf.2017.03.024 ↗
49. Zybina O, Gravit M (2020) Intumescent coatings for fire protection of Building structures and materials. Springer10.1007/978-3-030-59422-0 ↗
50. Ross R (2021) Wood handbook — Wood as an engineering material, in General Technical Report FPL-GTR-282, U.S. Department of Agriculture, Forest Service, Forest Products Laboratory
51. Methods for fire tests on building materials, components and structures — Fire-resistance tests for elements of construction, AS 1530.4–2014, ed. (2014)
52. Standard Specification and Temperature-Electromotive Force (EMF) Tables for Standardized Thermocouples, ASTM International E230/E230M, ed. (2012)
53. Beck JV (1962) Thermocouple temperature disturbances in low conductivity materials. ASME J Heat Mass Transf 124–131. https://doi.org/10.1115/1.368431010.1115/1.3684310 ↗
54. Pope I, Hidalgo JP, Hadden RM, Torero JL (2022) A simplified correction method for thermocouple disturbance errors in solids. Int J Therm Sci 172:107324. https://doi.org/10.1016/j.ijthermalsci.2021.10732410.1016/j.ijthermalsci.2021.107324 ↗
55. Boone R, Wengert E (1998) Guide for using the Oven-Dry method for determining the moisture content of wood, in forestry. Facts, University of Wisconsin
56. MATLAB, version 9.5.0944444 (R (2018b)). Natick, Massachusetts: The MathWorks Inc., 2018). Natick, Massachusetts: The MathWorks Inc., 2018
57. Wiesner F et al (2025) Large-scale compartment fires to develop a self-extinction design framework for mass timber-Part 2: results, analysis and design implications. Fire Saf J p. 104346. https://doi.org/10.1016/j.firesaf.2025.10434610.1016/j.firesaf.2025.104346 ↗
58. Emberley R, Do T, Yim J, Torero JL (2017) Critical heat flux and mass loss rate for extinction of Flaming combustion of timber. Fire Saf J 91:252–258. https://doi.org/10.1016/j.firesaf.2017.03.00810.1016/j.firesaf.2017.03.008 ↗
59. Friquin KL (2011) Material properties and external factors influencing the charring rate of solid wood and glue-laminated timber. Fire Mater 35(5):303–327. https://doi.org/10.1002/fam.105510.1002/fam.1055 ↗
60. Bartlett AI, Hadden RM, Bisby LA (2019) A review of factors affecting the burning behaviour of wood for application to tall timber construction. Fire Technol 55:1–49. https://doi.org/10.1007/s10694-018-0787-y10.1007/s10694-018-0787-y ↗
61. Zelinka SL, Hasburgh LE, Bourne KJ, Tucholski DR, Ouellette JP, Kochkin V (2018) Compartment fire testing of a two-story mass timber building, in Geneneral Technical Report FPL-GTR-247, U.S. Department of Agriculture, Forest Service, Forest Products Laboratory10.2737/FPL-GTR-247 ↗
62. Pope I et al (2023) Fully-developed compartment fire dynamics in large-scale mass timber compartments. Fire Saf J 141:104022. https://doi.org/10.1016/j.firesaf.2023.10402210.1016/j.firesaf.2023.104022 ↗