Fire Extinguishing Agents for Protection of Occupied Spaces in Military Ground Vehicles
Source abstract
Abstract
Historically the US Army used Halon 1301 (bromotrifluoromethane), a chemical with high ozone depletion potential (ODP), to protect the crews of armored vehicles from the effects of peacetime and combat fires. Since the phase-out of Halon production the US Army has directed that zero ODP materials be used wherever possible. Subsequently, major new vehicle platforms have been deployed with automatic fire extinguishing systems (AFES) that rely on HFC-227BC, a zero-ODP-agent blend of HFC-227ea (heptafluoropropane) and sodium-bicarbonate-based dry chemical. Unfortunately, hydrofluorocarbons (HFCs) generally have high global warming potential (GWP)—thousands of times that of carbon dioxide on a weight basis. Hence, as part of a larger effort to reduce its carbon footprint, US Army Program Managers have asked that fire extinguishing agents that are more environmentally friendly be evaluated as part of ongoing vehicle modernization efforts. Several agents were investigated, including FK-5-1-12, water with additives, and dry chemicals. This report describes the findings of more than 150 live-fire tests using nine agents and four extinguisher technologies. The basic conclusion is that no alternate agent can yet be considered to be a practical replacement for Halon 1301 or HFC-227BC for this application. However, a blend of Halon 1301 and dry chemical has been found to be about twice as effective as Halon 1301 alone. Thus, pending confirmation tests on vehicles, it may be feasible to use less Halon in legacy systems without compromising fire protection performance.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Occupational Health and Performance
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (28)
Show source-provided references
1. MIL-HDBK-684 (1995) Military handbook design of combat vehicles for fire survivability
2. Cinzori RJ (1977) Dual spectrum infrared fire sensor. IRIS, 15 June 1977
3. Koffinke MAJ (1991) Real time battle damage assessments. US Army, Ballistic Research Lab, On Assignment in Desert Storm
4. McCormick SJ, Clauson M, Cross H (2000) US army ground vehicle crew compartment Halon replacement program. In: Halon options technical working conference (HOTWC), 2–4 May 2000
5. Hodges SE, DiRaimo L (2004) Automatic fire extinguishing system (AFES) alternate agent integration challenges. In: Proceedings of 15th annual ground vehicle survivability symposium (GVSS), April 2004
6. Ryzyi M (2004) Stryker fire suppression system qualification. In: Proceedings of 15th annual ground vehicle survivability symposium (GVSS), April 2004
7. Hodges SE (2006) Challenges in integrating Halon-alternate agents into automatic fire extinguishing systems (AFES). In: Halon options technical working conference (HOTWC), 16 May 2006
8. World Meteorological Organization (WMO) (1998) Model-derived method
9. Intergovernmental Panel on Climate Change (IPCC) (2007) 4th assessment report
10. US Environmental Protection Agency (2009) Endangerment and cause or contribute findings for greenhouse gases under Section 202(a) of the clean air act. Climate Change Division, Office of Atmospheric Programs, US Environmental Protection Agency, 17 April 2009
11. Waxman and Markey (Reps) (2009) American clean energy and security Act of 2009. US Congress, HR2454, 15 May 2009
12. ATC Private Communication (2009) FTIR methodology to distinguish Novec 1230 and COF2 spectra. ATC Private Communication, March 2009
13. Ripple G, Mundie T (1989) Medical evaluation of nonfragment injury effects in armored vehicle live fire tests. Walter Reed Army Institute of Research, September 1989
14. Swanson G (1987) Fire survivability parameters for Combat vehicle crewmen. Memo to the US Army Surgeon General, 20 February 1987
15. US Army Pamphlet 40-501 (1998) Acceptable noise levels for this application are defined in section 6-2c(2) of Hearing conservation program. US Army Pamphlet 40-501, 10 December 1998
16. Januszkiewicz AJ, Davis EG (2003) Evaluation of potential physical injury from mechanical forces due to automatic fire extinguisher system discharge in the STRYKER combat vehicle: an initial assessment and recommendations to prevent injury. Walter Reed Army Institute of Research, 21 August 2003 (U/Limited Distribution)
17. NFPA (2001) Standard on clean agent fire extinguishing systems, 2008 edn. National Fire Protection Agency (NFPA), Quincy, MA, 15 August 2007
18. Rabash DJ (1986) Quantification of explosion parameters for combustible fuel-air mixtures Fire Saf J 11:113–125. The volume factor is discussed in Eckhoff RK, Use of (dP/dt)max from closed-bomb tests for predicting violence of accidental dust explosions in industrial plants. Fire Saf J 8:159–168 (1984/85)10.1016/0379-7112(85)90053-0 ↗
19. Eckhoff RK (1984/1985) Use of (dP/dt)max from closed-bomb tests for predicting violence of accidental dust explosions in industrial plants. Fire Saf J 8:159–16810.1016/0379-7112(85)90053-0 ↗
20. Moore PE (1996) Suppressants for the control of industrial explosions. J Loss Prev Process Ind 9(1):119–12310.1016/0950-4230(95)00045-3 ↗
21. Dessicarb (2007) DXP-1—US/Canada Version. MSDS KA012, Kidde Aerospace & Defense, 12 October 2007
22. Toxicity Evaluation of Acute Exposure to Dessicarb (1993) US Army Environmental Hygiene Agency, Toxicological Study No. 75-51-Y1F8-94, October 1993
23. Robert G, Daniel R, Skaggs R (1998) Test report: light attenuation by powder fire fighting agents. ARL Report for Tests 03-14 August 1998
24. http://www.nrl.navy.mil/content.php?P=PURPLEK . Accessed 17 Nov 2011
25. Reed M, Fleming J, Williams B, Sheinson R Chattaway A, Laverty N, Spring D (1997) Laboratory evaluation of bicarbonate powders as fire suppressants. In: Proceedings of international conference of ozone protection technologies, pp 333–344
26. Kim A, Crampton G, Kanabus-Kaminska M (2008) Evaluation of gas generator system with NOVEC 1230 agent as a replacement for crew compartment protection halon system. National Research Council Canada, Report B-4193.1, 31 March 2008 (See Table 4.1)
27. Ditch B, Rivers P, Thomas S (2002) A continuation of thermal decomposition product testing with C6 F-ketone, increased concentrations. In: Halon options technical working conference (HOTWC), May 2002
28. Hodges SE, McCormick SJ (2009) Evaluation of fire suppression agents for protection of occupied spaces in military ground vehicles. Proceedings of ground vehicle survivability symposium (GVSS), August 2009