Scattering Characteristics of Fire Smoke and Dust Aerosol in Aircraft Cargo Compartment
Source abstract
Abstract
Photoelectric smoke detectors, commonly used in aircraft cargo compartments, have high false alarm rates, which may result in huge economic losses and threaten flight safety. Dust aerosols are conventionally considered the main reason for this. Distinguishing dust aerosols from fire smoke by considering the difference between their scattering characteristics using a relatively simple combination of optical elements is crucial for reducing the false alarm rate. According to the relevant provisions for fire smoke and dust specified in the aerospace standard (AS 8036A) of the Society of Automotive Engineers (SAE) and considering the common cargo types, we studied the scattering characteristics of three types of aerosols, including six non-flaming fire smokes, four flaming fire smokes, and two dust aerosols, through numerical calculation and experimental methods. The results showed that these aerosols have different light scattering characteristics for forward and backward scattering due to particle size, morphology, etc. Considering these differences, we distinguished fire smoke from dust aerosols and reduced the false alarm rate in photoelectric smoke detectors in aircraft cargo compartments using an optimised optical structure design with dual wavelengths of 405 and 850 nm and dual scattering angles of 45° and 135°.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Aerosol Filtration and Electrostatic Precipitation · Radiative Heat Transfer Studies · Particle Dynamics in Fluid Flows
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (32)
Show source-provided references
1. Zhang HP, Lu S, Zhang D, Liu CC (2017) Introduction to aircraft fire prevention technology. Science Press, Beijing
2. Berlowitz I (2012) Cargo fire protection systems for freighter conversions. In: Proceedings of the 28th Congress of the International Council of the Aeronautical Sciences 2012, ICAS 2012, September 23, 2012–September 28, 2012, Brisbane, Australia, F, 2012. ICAS Secretariat
3. Hipsher C, Ferguson DE (2011) Fire protection: cargo compartments. Aero Mag 42:11–19
4. Code of Federal Regulations 14 CFR Part 25.858 (2006) Cargo or Baggage Compartment Smoke or Fire Detection Systems
5. Deng T (2017), Multi-parameter fire detection method based on dual wavelengths, Huazhong University of Science and Technology, (in Chinese)
6. Keller A, Loepfe M, Nebiker P et al (2006) On-line determination of the optical properties of particles produced by test fires. Fire Saf J 41:266–27310.1016/j.firesaf.2005.10.001 ↗
7. Gabrio T (2009) Strategie der Messung von Feinstaub in Innenräumen, Seminar “Nanopartikel in der Atmosphäre, Quellen - (Aus)Wirkungen - Messtechnik”, Berlin
8. Krüll W, Schultze T, Tobera R, Willms I (2013) Analysis of dust properties to solve the complex problem of non-fire sensitivity testing of optical smoke detectors. Procedia Eng 62:859–86710.1016/j.proeng.2013.08.136 ↗
9. DMT, Test Dust, Körnungskennlinie Dolomit 90, DMT Corporation, Essen
10. Cole M (2009) Aerosol characterisation for reliable ASD operation. In: 14th International Conference on Automatic Fire Detection, Duisburg
11. Deng T, Wang S, Zhu M (2016) Dual-wavelength optical sensor for measuring the surface area concentration and the volume concentration of aerosols. Sensor Actuat B 236:334–34210.1016/j.snb.2016.06.031 ↗
12. Wang S, Xiao X, Deng T, Chen A, Zhu M (2019) A Sauter mean diameter sensor for fire smoke detection. Sensor Actuat B 281:920–93210.1016/j.snb.2018.11.021 ↗
13. Xie QY, Zhang YM, Yuan HY, Zhao JH, Qiao LF, Jiang YL (2006) A spheroid model used to analyze effects of nonsphericity of smoke particles on light scattering patterns. J Univ Sci Technol China 36:320–327
14. Philipp JB, Hopfe A, Wedler G, Rosam A (2014) Pure optical false alarm resisting smoke detector. In: 15th International Conference on Automatic Fire Detection, Duisburg
15. Philipp JB, Kirbach K, Hofmann M, Hopfe A, Schank M, Behrens R, Wedler G (2017) False alarm resisting smoke detector for mobility application. In: 16th international conference on automatic fire detection, Maryland
16. Schultze T, Willms I (2014) Polarized light scattering smoke detector with reduced false alarm susceptibility. In: 15th International Conference on Automatic Fire Detection, Duisburg
17. Schultze T, Marcius L, Krüll W, Willms I (2017) Polarised light scattering analyses for aerosol classification. In: 16th International Conference on Automatic Fire Detection & Suppression, Detection and Signaling Research and Applications Conference, Maryland
18. Laven P (2011) MiePlot: a computer program for scattering of light from a sphere using Mie theory & the Debye series. http://www.philiplaven.com/mieplot.htm
19. Draine B, Flatau P (2013) User guide for the discrete dipole approximation code DDSCAT 7.3 http://arxiv.org/abs/1305.6497.
20. Yang SL (2016) Soot production and its scattering properties of a N-heptane pool fire under low pressures, University of Science and Technology of China (in Chinese)
21. Juranyi Z, Loepfe M, Nenkov M, Burtscher H (2017) Multi-angle, dual wavelength scattering measurement chamber for the structural measurement of combustion generated particles. J Aerosol Sci 103:83–9210.1016/j.jaerosci.2016.10.007 ↗
22. Shao SY, Huang YB, Wei HL et al (2009) Phase function of prolate spheroidic mono-disperse aerosol particles. Acta Optica Sinica 29:108–11310.3788/AOS20092901.0108 ↗
23. SAE Aerospace Standard AS 8036, Cargo Compartment Fire Detection Instruments, Rev. A, 2013-12-17
24. ISO 12103-1 (1997) Road Vehicles-Test Dust for Filter Evaluation-Arizona Test Dust
25. Krüll W, Schultze T, Willms I, Freiling A (2011) Developments in non-fire sensitivity testing of optical smoke detectors-proposal for a new test method, Fire. Saf Sci 10:543–554
26. Tobera R, Krüll W, Schultze T, Willms I (2014) Apparatus for the test of fire detectors in high humidity environments. In: 15th International Conference on Automatic Fire Detection, Duisburg
27. Tobera R, Krüll W, Schultze T, Willms I (2014) Apparatus for the test of fire detectors in high foggy environments. In: 15th International Conference on Automatic Fire Detection, Duisburg
28. Krüll W, Schultze T, Tobera R, Willms I (2014) Characterization of dust aerosols in false alarm scenarios. In: 15th International Conference on Automatic Fire Detection, Duisburg
29. Krüll W, Schultze T, Tobera R, Willms I (2014) Apparatus for the test of fire detectors in dusty environments. In: 15th International Conference on Automatic Fire Detection, Duisburg
30. Krüll W, Schultze T, Willms I (2017) Non-fire sensitivity testing of optical smoke detectors. In: 16th International Conference on Automatic Fire Detection & Suppression, Detection and Signaling Research and Applications Conference, Maryland
31. Zheng R, Zhang D, Lu S, Yang SL (2019) Discrimination between fire smokes and nuisance aerosols using asymmetry ratio and two wavelengths. Fire Technol 55:1753–177010.1007/s10694-019-00829-5 ↗
32. Deng T (2017) Multi-parameter fire detection method based on dual wavelengths, Huazhong University of Science and Technology. (in Chinese)