journal article·2020-09Open access

Experimental Study on Vulnerabilities of Japanese-Style Tile Roof Assemblies to Firebrand Exposures

Sayaka Suzuki, Samuel L. Manzello

Fire Technology· Volume 56· Issue 5

Abstract

Roof assemblies are known to be vulnerable to firebrands in urban and wildland-urban interface fires. In the 2016 urban fire in Japan (Itoigawa-City Fire), at least 10 structures were ignited by firebrand showers and three of these structures were ignited by firebrand penetration under tile roof assemblies. In this study, the vulnerabilities of Japanese-style roof tile assemblies to firebrand exposures were investigated by using a continuous-feed firebrand generator with applied nominal wind speeds of 6 m/s and 9 m/s. It was observed that Japanese-style roof tile assemblies were more vulnerable than concrete flat, concrete profile, and terracotta flat roof tiles for applied wind speeds of 6 m/s. When the experiments were performed with debris placed underneath the roof tiles, penetrated firebrands ignited debris. Flaming ignition was observed under 9 m/s where flame was observed to protrude from the tiles in an effort to reach necessary oxygen for combustion.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire effects on ecosystems · Fire dynamics and safety research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (19)

Show source-provided references
1. Thomas D et al (2017) The costs and losses of wildfires. NIST Special Publication 1215. https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.1215.pdf
2. Manzello SL, Foote EID (2014) Characterizing firebrand exposure from wildland–urban interface (WUI) fires: results from the 2007 Angora fire. Fire Technol 50:105–124. http://dx.doi.org/10.1007/s10694-012-0295-410.1007/s10694-012-0295-4 ↗
3. Maranghides A et al (2015) A case study of a community affected by the waldo fire—event timeline and defensive actions. NIST TN1910. https://doi.org/10.6028/nist.tn.191010.6028/nist.tn.1910 ↗
4. Suzuki S (2017) A review on structure ignitions by firebrands. Bull Jpn Assoc Fire Sci Eng. 67(1):49–55 (in Japanese)
5. National Research Institute of Fire and Disaster (2018) Report on Itoigawa fire. NRIFD technical report No. 84
6. Suzuki S, Manzello SL (2018) Characteristics of firebrands collected from actual urban fires. Fire Technol 54:1533–154610.1007/s10694-018-0751-x ↗
7. ISO 12468-1:2013 External exposure of roofs to fire—part 1 test method
8. Manzello SL (2014) Enabling the investigation of structure vulnerabilities to wind- driven firebrand showers in wildland-urban interface (WUI) fires. Fire Saf Sci 11:83–96. http://dx.doi.org/10.3801/IAFSS.FSS.11-8310.3801/IAFSS.FSS.11-83 ↗
9. Manzello SL, Hayashi Y, Yoneki T, Yamamoto Y (2010) Quantifying the vulnerabilities of ceramic tile roofing assemblies to ignition during a firebrand attack. Fire Saf J 45:35–4310.1016/j.firesaf.2009.09.002 ↗
10. Manzello SL (2013) The performance of concrete tile and terracotta tile roofing assemblies exposed to wind-driven Firebrand showers. NIST technical note 1794. http://dx.doi.org/10.6028/NIST.TN.179410.6028/NIST.TN.1794 ↗
11. Suzuki S, Manzello SL, Nii D (2017) The performance of wood and tile roofing assemblies exposed to continuous firebrand assault. Fire Mater 41:84–96. http://dx.doi.org/10.1002/fam.237210.1002/fam.2372 ↗
12. Suzuki S, Manzello SL (2017) Experiments to prove the scientific-basis for laboratory standard test methods for firebrand exposure. Fire Saf J (Special issue on fire safety science—proceedings of 12th international symposium) 91:784–790
13. JIS A 5423:2013 Decorated cement shingles for dwelling roofs
14. Manzello SL, Suzuki S (2017) Generating wind driven firebrand showers characteristics of burning structures. Proc Combust Inst 36:3247–325210.1016/j.proci.2016.07.009 ↗
15. Kawara Yane Hyojun Sekou Youryousho, JKY-2014. http://www.yane.or.jp/manual/53a/pdf_53a.pdf. Accessed 16 Apr 2020
16. SL Manzello, TG Cleary, JR Shields, JC Yang (2006) Ignition of mulch and grasses by firebrands in wildland–urban interface fires. Int J Wildland Fire, 15(3):427–43110.1071/WF06031 ↗
17. Manzello SL et al (2008) Experimental investigation of firebrands: generation and ignition of fuel beds. Fire Saf J 43(3)::226–23310.1016/j.firesaf.2006.06.010 ↗
18. Manzello SL et al (2006) On the ignition of fuel beds by firebrands. Fire Mater 30(1):77–8710.1002/fam.901 ↗
19. Drysdale D (2011) An introduction to fire dynamics, 3rd edn. Wiley, London10.1002/9781119975465 ↗