Abstract

The pattern of the firefighter’s movement during fire exposure remarkably affects the protective performance of the firefighting suit. In addition, thermal energy transfer through the suit to the body, which determines the protective performance of the suit, takes place primarily by radiation heat transfer. Therefore, this study numerically investigates the influence of reducing the radiation heat transfer between the layers of the firefighting suit and from the suit to the body on the protective performance of the suit for different patterns of the firefighter’s movement. Specifically, the influence of reducing the emissivity (from 0.9 to 0.1) of the backside surface of each layer of the suit on the protective performance of the suit was explored for a variation in the frequency (from 0 rps to 4 rps) and amplitude (from 0.5 mm to 3 mm) of the periodic motion of the suit relative to the body. The results showed that reducing the emissivity of the backside surface of any of the layers of the suit improves the protective performance of the suit for high frequencies and low amplitudes of the motion. Moreover, reducing the emissivity of the backside surface of the thermal liner layer has the highest effect among the layers of the suit on the protective performance of the suit.
Source: expertdata · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Thermoregulation and physiological responses · Winter Sports Injuries and Performance · Radiative Heat Transfer Studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (18)

Show source-provided references
1. International Organization for Standardization (2016) ISO 9151 protective clothing against heat and flame-determination of heat transmission on exposure to flame. International Organization for Standardization, Geneva
2. American Society for Testing Materials (2000) ASTM F 1930-00 Standard Test Method For Evaluation Of Flame Resistant Clothing For Protection Against Flash Fire Simulations Using An Instrumented Thermal Manikin. West Conshohocken, PA
3. National Fire Protection Association (2018) NFPA 1971 Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting. Massachusetts, USA
4. Udayraj, Talukdar P, Das A, Alagirusamy R (2016) Heat and mass transfer through thermal protective clothing: a review. Int. J. Thermal Sciences 106:32–5610.1016/j.ijthermalsci.2016.03.006 ↗
5. Ghazy A (2017) The thermal protective performance of firefighters’ clothing: the air gap between the clothing and the body. Heat Transfer Eng 38(10):975–98610.1080/01457632.2016.1212583 ↗
6. Ghazy A (2020) On the protective performance of firefighters’ garments: air gaps between fabric layers. Fire Technol. J. 56(2):821–83610.1007/s10694-019-00905-w ↗
7. Elgafy A, Mishra S (2014) A heat transfer model for incorporating carbon foam fabrics in firefighter’s garment. Heat Mass Transfer 50:545–57510.1007/s00231-013-1259-z ↗
8. Udayraj, Talukdar P, Das A, Alagirusamy R (2017) Numerical modeling of heat transfer and fluid motion in air gap between clothing and human body: effect of air gap orientation and body movement. Int. J. Heat Mass Transfer 108:271–29110.1016/j.ijheatmasstransfer.2016.12.016 ↗
9. Ghazy A, Bergstrom DJ (2013) Numerical simulation of the influence of fabric’s motion on protective clothing performance during flash fire exposure. Heat Mass Transfer 49:775–78810.1007/s00231-013-1123-1 ↗
10. Xin L, Li X, Li J (2014) A new approach to evaluate the effect of body motion on heat transfer of thermal protective clothing during flash fire exposure. Fibers Polym. 15(10):2225–223110.1007/s12221-014-2225-1 ↗
11. Ghazy A (2019) Influence of the fabric properties on the protective performance of flame resistant clothing during the body movement. Fire Technol. J. 55(3):713–72810.1007/s10694-018-0802-3 ↗
12. Ghazy A, Bergstrom DJ (2012) Numerical simulation of heat transfer in firefighters’ protective clothing with multiple air gaps during flash fire exposure. Numer. Heat Transfer A 61:569–59310.1080/10407782.2012.666932 ↗
13. Ghazy A (2021) Evaluating the protective performance of municipal firefighting suits during firefighter’s motion under fire exposure. Fire Technol. J. 57(4):1827–184610.1007/s10694-021-01095-0 ↗
14. Xu Q, Li R, Shen L, Xu W, Wang J, Jiang Q, Zhang L, Fu F, Fu Y, Liu X (2019) Enhancing the surface affinity with silver nano-particles for antibacterial cotton fabric by coating carboxymethyl chitosan and L-cysteine. Appl. Surf. Sci. 497:14367310.1016/j.apsusc.2019.143673 ↗
15. Rezaei F, Maleknia L, Valipour P, Fard GC (2016) Improvement properties of nylon fabric by corona pre-treatment and nano coating. J. Textile Inst. 107(10):1223–123110.1080/00405000.2015.1100394 ↗
16. Henriques FC Jr, Moritz AR (1947) Studies of thermal injuries I: the conduction of heat to and through skin and the temperatures attained therein. A theoretical and experimental investigation. Am. J. Pathol. 23:531–549
17. Chai JC, Patankar SV (2000) Finite-volume method for radiation heat transfer, advances. In: Minkowycz WJ, Sparrow EM (eds) Numerical heat transfer. Taylor & Francis, New York
18. Mercer GN, Sidhu HS (2008) Mathematical modeling of the effect of fire exposure on a new type of protective clothing. ANZIAM 49:C289–C30510.21914/anziamj.v49i0.346 ↗