journal article·2024-07Open access

Fire Tests on Steel–Timber Composite Beams

Antoine Béreyziat, Dhionis Dhima, Sébastien Durif, Maxime Audebert, Abdelhamid Bouchaïr, Amir Si Larbi

Fire Technology· Volume 60· Issue 4

Abstract

The fire resistance and the thermomechanical behaviour of Steel-Timber Composite (STC) beams are studied through 4 fire tests. 35 non-loaded reduced specimens and 2 mechanically loaded real-scale beams are tested considering standard fire conditions (ISO 834 temperature-time curve). They consist in various steel profiles associated with timber elements in such a way that steel is fully or partially protected from fire. Timber is used as a fire protective material since it has a low conductivity and a low charring rate. Fire tests on non-loaded reduced specimen allow to investigate a wide variety of configurations, and to identify key parameters. It is found that full timber protection is very efficient as steel remains below 250°C during 35 or 70 minutes when timber protection is respectively 30 or 50mm thick. Moreover, timber moisture is found to have a beneficial impact on steel temperature, while hollow sections favour timber combustion and steel heating during the cooling phase. Full-scale mechanically loaded fire tests highlight the importance of assembly joints, because deflexion can open it, which accelerate the heating of steel. Finally, an 81 min fire resistance is measured for a STC beam with 45mm timber protection. These finding contribute to better understand the behaviour of steel-timber structural elements in fire situation. It appears that judicious mixing of timber and steel can lead to improved performances in both normal and fire situations. The presented results can be used to improve the design of STC beams.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Wood Treatment and Properties · Fire effects on concrete materials · Fire dynamics and safety research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (28)

Show source-provided references
1. Nabati A, Ghanbari-Ghazijahani T, Valipour HR (2021) Innovative flitch sandwich beams with steel core under four-point bending. Eng Struct 233:111724. https://doi.org/10.1016/j.engstruct.2020.11172410.1016/j.engstruct.2020.111724 ↗
2. Fujita M, Iwata M (2013) Bending test of the composite steel–timber beam. Appl Mech Mater 351–352:415–421. https://doi.org/10.4028/www.scientific.net/AMM.351-352.41510.4028/www.scientific.net/AMM.351-352.415 ↗
3. Winter W, Tavoussi K, Riola Parada F, Bradley A (2016) Timber–steel hybrid beams for multi-storey buildings: final report. Paper presented at the World Conference on Timber Engineering
4. Duan S, Zhou W, Liu X, Yuan J, Wang Z (2021) Experimental study on the bending behavior of steel-wood composite beams. Adv Civil Eng 2021:1315849. https://doi.org/10.1155/2021/131584910.1155/2021/1315849 ↗
5. Jurkiewiez B, Durif S, Bouchair A, Grazide C (2022) Experimental and analytical study of hybrid steel-timber beams in bending. Structures 39:1231–1248. https://doi.org/10.1016/j.istruc.2022.03.05510.1016/j.istruc.2022.03.055 ↗
6. European Committee for Standardization (2004): EN 1995-1-2 - Eurocode 5 - Design of timber structures - Part 1-2: General - Structural fire design
7. (1883) Flitch-plate, riveted and trussed girders. The American Architect and Building News 13:255–258
8. Twilt L, Witteveen J (1974) The fire resistance of wood-clad steel columns. Fire Prev Sci Technol 11:14–20
9. Uesugi S, Harada T, Namiki Y (2002) Fire resistance of sugi covering materials for structural steel. J Wood Sci 48(4):343–345. https://doi.org/10.1007/BF0083135810.1007/BF00831358 ↗
10. Shiraiwa M, Yusa S, Masuda H, Kawai T-A, Namiki Y, Saito H (2004) Fire resistance on hybrid wooden structure, Part 8: Experimental fire resistance study on self-charring-stop wooden column structure. Paper presented at the Annual meeting of Architectural Institute of Japan
11. Masuda H, Yusa S, Kawai T-a, Namiki Y (2004) Fire resistance of hybrid wooden structure, Part 9: Loaded fire resistance test on heavy-timber beam structure. Paper presented at the Annual meeting of Architectural Institute of Japan
12. Sakamoto I, Kawai N, Okada H, Yusa S (2004) Final report of a research and development project on timber-based hybrid building structures. Paper presented at the World Conference on Timber Engineering
13. JR East Design Corporation (2016) Kunimi town office building. Steel construction Today & Tomorrow (49):15–18
14. Buchanan A, Östman B (2022) Fire safe use of wood in buildings: global design guide. CRC Press, Boca Raton. https://doi.org/10.1201/978100319031810.1201/9781003190318 ↗
15. Timbersize: (2017). http://www.timberize.com/index.html?target=417 Accessed 03 July 2022
16. Jang S-S, Kim Y-H, Jang Y-I, Shin I-J (2010) Fire resistance of steel column glued with structural glulam covers. Paper presented at the World Conference on Timber Engineering
17. Riola-Parada F, Tavoussi K, Fadai A, Winter W, Stockert L (2018) Fire performance of prefabricated timber-steel-concrete ribbed decks. Paper presented at the World Conference on Timber Engineering10.4028/www.scientific.net/AMM.887.21 ↗
18. European Committee for Standardization (2020) EN 1363-1 - Fire resistance tests - Part 1: General requirements
19. European Committee for Standardization (2002) EN 13183-1 - Moisture content of a piece of sawn timber - Part 1: Determination by oven dry method
20. European Committee for Standardization (2005) EN 1993-1-2 - Eurocode 3 - Design of steel structures - Part 1-2: General rules - Structural fire design
21. White RH, Schaffer EL (1981) Transient moisture gradient in fire-exposed wood slab. Wood Fiber Sci 13(1):17–38
22. Audebert M, Dhima D, Taazount M, Bouchaïr A (2014) Experimental and numerical analysis of timber connections in tension perpendicular to grain in fire. Fire Saf J 63:125–137. https://doi.org/10.1016/j.firesaf.2013.11.01110.1016/j.firesaf.2013.11.011 ↗
23. Samaké A, Taazount M, Audebert P, Palmili P (2014) Thermo-hydric transfer within timber connections under fire exposure: experimental and numerical investigations. Appl Thermal Eng 63(1):254–265. https://doi.org/10.1016/j.applthermaleng.2013.10.04910.1016/j.applthermaleng.2013.10.049 ↗
24. Sedighi Gilani M, Hugi E, Carl S, Palma P, Vontobel P (2015) Heat induced desorption of moisture in timber joints with fastener during charring. Fire Technol 51(6):1433–1445. https://doi.org/10.1007/s10694-014-0416-310.1007/s10694-014-0416-3 ↗
25. Alam P, Ansell M (2012) The effects of varying nailing density upon the flexural properties of flitch beams. J Civil Eng Res 2(1):7–13. https://doi.org/10.5923/j.jce.20120201.0210.5923/j.jce.20120201.02 ↗
26. Łukomski M, Turkowski P, Roszkowski P, Papis B (2017) Fire resistance of unprotected steel beams-comparison between fire tests and calculation models. Procedia Eng 172:665–672. https://doi.org/10.1016/j.proeng.2017.02.07810.1016/j.proeng.2017.02.078 ↗
27. Newman G, Simms I (1999) The cardington fire tests. North American Steel Construction Conference