Fire ventilation measures taken by fire & rescue services, including positive pressure ventilation, were investigated. Fifteen tests were performed in a three-room apartment, with an attached staircase, on the first floor of a training facility. The fire source was a 0.5 m diameter pool of heptane. The temperature and pressure in the apartment, the weight of the fire source, and the flow through openings were recorded continuously. The tests showed that the rate of burning was increased by positive pressure ventilation. Also, positive pressure ventilation increases the temperature in rooms on the leeward side of the fire and reduces temperatures in rooms on the windward side of the fire. Safety and working conditions for fire fighters are improved by positive pressure ventilation, but it jeopardises the lives of anyone that might be trapped. The importance of command and control during fire fighting operations is prominent.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Education, Safety, and Science Studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (12)

Show source-provided references
1. Federal Emergency Management Agency, United States Fire Administration, Fire in the United States 1987- 1996, 11th ed., 1999.
2. Räddningstjänst i siffror 1998 (Swedish statistics on fires and fire & rescue service operations. In Swedish). Räddningsverket, Karlstad, 1999.
3. A. Hay, A Survey of Fire Ventilation Home Office, Publication No. 6/94, London: Home Office Fire Research and Development Group, 1994.
4. The International Fire Service Association (IFSTA), Essentials of Fire Fighting, 3rd ed., Oklahoma State University: Fire Protection Publications, 1992.
5. Fire Service Manual; Fire Service Operations, vol. 2: Compartment Fires and Tactical Ventilation. London: Home Office, 1997.
6. Brandgasventilation (In Swedish). Karlstad: Räddningsverket, 2000.
7. P.S. Ziesler, F.S. Gunnerson, and S.K. Williams, “Advances in Positive Pressure Ventilation,” Fire Technology, vol. 30, 2nd quarter, 1994, pp. 269–277.10.1007/BF01040006 ↗
8. J.G. Rimen, An Assessment of the Use of Positive Pressure Ventilation in Domestic Properties, (Home Office Publication No. 17/96). London: Home Of.ce Fire Research and Development Group, 1996.
9. S. Svensson, Försök med brandgasventilation i en liten lägenhet (in Swedish), Report R53–159/96. Karlstad: Räddningsverket, 1996.
10. V. Babrauskas, “Burning Rates,” in The SFPE Handbook of Fire Protection Engineering, 1st ed., Quincy, MA: NFPA, 1988, pp 2–3–2–4.
11. http://haleproducts.com/.
12. S.-E. Magnusson, Smoke Movement in Buildings: A State-of-Art Review and a Program for Future Swedish Research (in Swedish with English summary). Lund: Lund Institute of Technology, 1983.