journal article·2011-10

Predicting the Fire Resistance of Wood–Steel–Wood Timber Connections

Lei Peng, George Hadjisophocleus, Jim Mehaffey, Mohammad Mohammad

Fire Technology· Volume 47· Issue 4
Publisher page

Abstract

This paper presents an investigation on the fire performance of wood–steel–wood timber connections with slotted-in steel plates. In the first part, a three-dimensional thermal model was employed that uses the finite element method to analyze heat transfer within timber connections exposed to the standard fire. The temperature-related properties were obtained from the literature and imported into the thermal model. A validation of the proposed thermal model was achieved by comparing predicted temperatures with experimental results. In the next phase, a reduction in the embedding strength method was adopted to estimate the load-carrying capacity of connections in fire. Based on the temperature profiles within the connection calculated by the thermal model, the reduction of the embedding strength was determined and used to calculate the load capacity at elevated temperatures. Furthermore, a formula was proposed to evaluate the fire resistance rating of timber connections and compared with the results of fire resistance tests. The parameters considered included the load level, fastener diameter and wood member thickness.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Wood Treatment and Properties · Tree Root and Stability Studies · Bamboo properties and applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (31)

Show source-provided references
1. Noren J (1996) Load-bearing capacity of nailed joints exposed to fire. Fire Mater 20:133–14310.1002/(SICI)1099-1018(199605)20:3<133::AID-FAM565>3.0.CO;2-3 ↗
2. Dhima D (1999) Verification experimentale de la resistance au feu des assemblages delements en bios. CTICM Ref. INC-99/399-DD/NB. CTICM, Paris, France
3. Kruppa J, Lamadon T, Rachet P (2000) Fire resistance test of timber connections. CTICM Ref. INC-00/187-JK/NB. CTICM, Paris, France
4. Ayme N (2003) Assemblages bois-metal en double cisaillement. Rapport Du Comportement Au Feu D’Assemblages Bois, CTICM Ref. SR21-03/121-NA/PB. CTICM, Paris, France
5. Erchinger C, Frangi A, Mischler A (2006) Thermal investigations on multiple shear steel-to-timber connections. In: 9th world conference on timber engineering WCTE, Portland/Oregon, USA
6. Laplanche K, Dhima D, Rachet P (2006) Thermo-mechanical analysis of the timber connection under fire using a finite element model. In: 9th world conference on timber engineering WCTE, Portland/Oregon, USA
7. Lau PH (2006) Fire resistance of connections in laminated veneer lumber. Fire Engineering Research Report 06/3. Dept. of Civil Engineering, University of Canterbury, New Zealand
8. Chuo TCB (2007) Fire performance of connections in LVL structures. Fire Engineering Research Report 07/4. Dept. of Civil Engineering, University of Canterbury, New Zealand
9. Konig J, Fontana M (2001) The performance of timber connections in fire test results and rules of Eurocode 5. In: Proceedings of international rilem symposium ‘Joints in Timber Structures’, University of Stuttgart: Rilem Publications s.a.r.l., Cachan, France
10. NBCC (2005) National Building Code of Canada. National Research Council of Canada, Ottawa, ON, Canada
11. Mehaffey JR (2003) Fire performance of heavy timber connections. Report No. 3223. Forintek Canada Corp., Ottawa, ON, Canada
12. Hibbitt, Karlsson & Sorensen Inc. (2006) ABAQUS/Standard user’s manual. ABAQUS Version 6.6. Pawtucket, Rhode Island
13. EN1991-1-2 (2003) Eurocode 1: actions on structures—Part 1-2: general actions—actions on structures exposed to fire. CEN, Brussels, Belgium
14. Mehaffey JR, Cuerrier P, Carisse G (1994) A model for predicting heat transfer through gypsum board/wood stud walls exposed to fire. Fire Mater 18:297–30510.1002/fam.810180505 ↗
15. EN1993-1-2 (2005) Eurocode 3—design of steel structures, Part 1-2: general rules—structural fire design. CEN, Brussels, Belgium
16. ISO834 (1999) Fire resistance tests—elements of building construction, Part 1: general requirements. International Organization for Standardization, Switzerland
17. Jaouen JL, Klarsfeld S (1987) Heat transfer through a still air layer. In: Powell FJ, Matthews SL (eds) Thermal insulation: materials and systems, ASTM STP 922. American Society for Testing and Materials, Philadelphia, pp 283–29410.1520/STP18486S ↗
18. Janssens ML (1994) Thermo-physical properties for wood pyrolysis models. In: Pacific timber engineering conference, Gold Coast, Australia
19. Knudson RM (1973) Performance of structural wood members exposed to fire. PhD dissertation, University of California, Berkeley, USA
20. Fredlund B (1993) Modelling of heat and mass transfer in timber structures during fire. Fire Saf J 20:39–6910.1016/0379-7112(93)90011-E ↗
21. Konig J, Walleij L (2000) Timber frame assemblies exposed to standard and parametric fires, Part 2: a design model for standard fire exposure. Rapport I 0001001. Swedish Institute for Wood Technology Research, Stockholm
22. Lie TT (1992) Structural fire protection. ASCE Manuals and Reports of Engineering Practice, No. 78. American Society of Civil Engineers, New York10.1061/9780872628885 ↗
23. Takeda H, Mehaffey JR (1998) WALL2D: a model for predicting heat transfer through wood-stud walls exposed to fire. Fire Mater 22:133–14010.1002/(SICI)1099-1018(1998070)22:4<133::AID-FAM642>3.0.CO;2-L ↗
24. White RH (2002) Analytical methods for determining fire resistance of timber members, Section 4/Chapter 11, SFPE handbook of fire protection engineering, 3rd edn. National Fire Protection Association, Quincy, MA
25. Konig J, Walleij L (1999) One-dimensional charring of timber exposed to standard and parametric fires in initially unprotected and post-protection fire situations. Rapport I 9908029. Swedish Institute for Wood Technology Research, Stockholm
26. CSA (2005) Engineering design in wood CAN/CSA-O86-1. Canadian Standards Association, Rexdale, ON, Canada
27. Johansen KW (1949) Theory of timber connectors. International Association of Bridge and Structural Engineering (IABSE), Bern, Switzerland
28. Moss PJ, Buchanan A, Fragiacomo M, Austruy C (2008) On the design of timber bolted connections subjected to fire. In: 5th international conference on structures in fire. Nanyang Technological University, Singapore
29. Moraes PD, Rogaume Y, Bocquet JF, Triboulot P (2005) Influence of temperature on the embedding strength. Holz als Roh- und Werkstoff 63(4):297–30210.1007/s00107-004-0568-9 ↗
30. EN1995-1-1 (2004) Eurodode 5—design of timber structures, Part 1-1: general rules and rules for buildings. CEN, Brussels, Belgium
31. EN1995-1-2 (2004) Eurodode 5—design of timber structures, Part 1-2: structural fire design. CEN, Brussels, Belgium