journal article·2013-10Open access

Analysis of One and Two-Story Single Family Home Fire Dynamics and the Impact of Firefighter Horizontal Ventilation

Stephen Kerber

Fire Technology· Volume 49· Issue 4

Abstract

Abstract This paper describes experimental investigations on fire service ventilation practices in modern house geometries. Two houses were constructed inside a large fire facility. The first of two houses constructed was a one-story, 111.5 m2, 3 bedroom, 1 bathroom house with 8 total rooms. The second house was a two-story 297.3 m2, 4 bedroom, 2.5 bathroom house with 12 total rooms. The second house featured a modern open floor plan, two-story great room and open foyer. Fifteen experiments were conducted varying the ventilation locations and the number of ventilation openings. Ventilation scenarios included ventilating the front door only, opening the front door and a window near and remote from the seat of the fire, opening a window only and ventilating a higher opening in the two-story house. One scenario in each house was conducted in triplicate to examine repeatability. The results of these experiments examine potential occupant tenability and provide knowledge for the fire service for them to examine their horizontal ventilation standard operating procedures and training content. The fire dynamics resulting from ventilation practices such as ventilation near or remote from the seat of the fire and high versus low in relation to the fire are examined. Several other tactical considerations were developed utilizing the data from these experiments to provide specific examples of changes that can be adopted based on a departments current strategies and tactics. Such tactical considerations and a systems approach to fire service tactics should be investigated further.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Occupational Health and Performance · Fire dynamics and safety research · Injury Epidemiology and Prevention

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (9)

Show source-provided references
1. Svensson, S (2005) Fire ventilation. Swedish Rescue Services Agency. Karlstad, Sweden. https://msb.se/RibData/Filer/pdf/20879.pdf
2. Kerber, S (2011) Analysis of changing residential fire dynamics and its implications on firefighter operational timeframes. Fire Technol Online First10.1007/s10694-011-0249-2 ↗
3. Fahy RF (2010) U.S. fire service fatalities in structure fires, 1977–2009, National Fire Protection Research Foundation
4. National Institute of Occupational Safety and Health (2010) One career fire fighter/paramedic dies and a part-time fire fighter/paramedic is injured when caught in a residential structure flashover-Illinois, Report No. 2010-10
5. National Institute of Occupational Safety and Health (2000) Volunteer fire fighter dies fighting a structure fire at a local residence-Texas, Report F2000-09
6. National Institute of Occupational Safety and Health (2008) Volunteer fire fighter and trapped resident die and a volunteer lieutenant is injured following a duplex fire-Pennsylvania, Report F2008-06
7. Kerber S (2009) Impact of ventilation on fire behavior in legacy and contemporary residential construction. Underwriters Laboratories, Inc., Northbrook
8. ISO 13571 (2007) Life-threatening components of fire: Guidelines for the estimation of time available for escape using fire data
9. http://www.ul.com/global/eng/pages/offerings/industries/buildingmaterials/fire/fireservice/ventilation/ . Accessed 12 Feb 2012