Structural Performance of Prestressed Composite Members with Corrugated Webs Exposed to Fire
Source abstract
Abstract
In this study, to assess the fire performances of corrugated webbed prestressed (CWPS) composite beams exposed to fire, full-scale fire resisting tests were carried out, and fire-resisting behavioural responses of the test specimens were analyzed and compared with those obtained from nonlinear finite element analyses. Key test variables were the cover thickness of the fire protection material applied to the bottom flange of corrugated webbed steel beams, which was directly exposed to fire, and the shapes of corrugated webs. All the composite beams with fire protection material covers exposed to standard fire showed good fire-resisting capacities with fire ratings over 3 h and in particular, CWPS composite beams with relatively thin fire protection material cover thickness, compared with the non-prestressed slim-floor composite beam, satisfied the required fire performance criteria in ISO 834 standard and Eurocode. Additionally, the test results showed that the shape of corrugated webs used in CWPS composite beam specimens could have a great impact on their fire-resisting performance. The nonlinear finite element analyses performed in this study accurately estimated the overall behaviours of test specimens and especially assessed the effects of the shape of the corrugated web on the temperature distributions and fire resistance performances of CWPS composite beams appropriately.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire effects on concrete materials · Structural Load-Bearing Analysis · Structural Behavior of Reinforced Concrete
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (52)
Show source-provided references
1. Mullett DL (1998) Composite floor systems. Blackwell Science, London
2. Kim KS, Lee DH, Choi SM, Choi YH, Jung SH (2011) Flexural behavior of prestressed composite beams with corrugated web: part I. Development and analysis. Compos Part B Eng 42:1603–161610.1016/j.compositesb.2011.04.020 ↗
3. Kim KS, Lee DH (2011) Flexural behavior of prestressed composite beams with corrugated web: Part II. Experiments and verification. Compos Part B Eng 42:1617–162910.1016/j.compositesb.2011.04.019 ↗
4. Oh JY, Lee DH, Kim KS (2012) Accordion effect in prestressed steel beams with corrugated webs. ThinWall Struct 57:49–61
5. Oh JY, Lee DH, Cho SH, Kang H, Cho HC, Kim KS (2015) Flexural behavior of prestressed steel-concrete composite members with discontinuous webs. Adv Mater Sci Eng 2015:278293 (1–13)10.1155/2015/278293 ↗
6. Easley, JT (1975) Buckling formulas for corrugated metal shear diaphragms. J Struct Div ASCE 101:1403–141710.1061/JSDEAG.0004095 ↗
7. Luo R, Edlund B (1994) Buckling analysis of trapezoidally corrugated panels using spline finite strip method. Thin Wall Struct 18:209–22410.1016/0263-8231(94)90019-1 ↗
8. Elgaaly M, Hamilton RW, Seshadri A (1996) Shear strength of beams with corrugated webs. J Struct Eng ASCE 122:390–39810.1061/(ASCE)0733-9445(1996)122:4(390) ↗
9. Azizinamini A, Barth K, Dexter R, Rubeiz C (2004) High performance steel: research front-historical account of research activities. J Bridge Eng 9:212–21710.1061/(ASCE)1084-0702(2004)9:3(212) ↗
10. Khalid Y, Chan C, Sahari B, Hamouda A (2004) Bending behaviour of corrugated web beams. J Mater Process Technol 150:242–25410.1016/j.jmatprotec.2004.02.042 ↗
11. Abbas HH, Sause R, Driver RG (2007) Analysis of flange transverse bending of corrugated web I-girders under in-plane loads. J Struct Eng ASCE 133:347–35510.1061/(ASCE)0733-9445(2007)133:3(347) ↗
12. Mirghaderi R, Sobhan S, Torabian S (2008) In reducing beam section by corrugated webs for developing a connection of specially moment resisting frame, structures congress 2008@ sCrossing Borders, ASCE, pp 1–1010.1061/41016(314)308 ↗
13. Ibrahim S (2015) Steel plate girders with corrugated webs, past, present and future. Dissertation, Ain Shams University
14. Driver RG, Abbas HH, Sause R (2006) Shear behavior of corrugated web bridge. J Struct Eng ASCE 132:195–20310.1061/(ASCE)0733-9445(2006)132:2(195) ↗
15. Lawson RM, Mullett DL, Rackham JW (1997) Design of asymmetric slimfloor beams using deep composite decking. The Steel Construction Institute, Ascot, Berks
16. Malaska M, Mäkeläinen P (1999) Study on composite slim floor beams. Laboratory of steel structures, Publications 9. Helsinki University of Technology, Espoo
17. Lorenc W, Kubica E (2006) Behavior of composite beams prestressed with external tendons: experimental study. J Constr Steel Res 62:1353–136610.1016/j.jcsr.2006.01.007 ↗
18. Chen S, Gu P (2005) Load carrying capacity of composite beams prestressed with external tendons under positive moment. J Constr Steel Res 61:515–53010.1016/j.jcsr.2004.09.004 ↗
19. Ayyub BM, Sohn YG, Saadatmanesh H (1990) Prestressed composite girders under positive moment. J Struct Eng ASCE 116:2931–295110.1061/(ASCE)0733-9445(1990)116:11(2931) ↗
20. Ayyub BM, Sohn YG, Saadatmanesh H (1992) Prestressed composite girders. I: experimental study for negative moment. J Struct Eng ASCE 118:2743–276210.1061/(ASCE)0733-9445(1992)118:10(2743) ↗
21. Ayyub BM, Sohn YG, Saadatmanesh H (1992) Prestressed composite girders. II: analytical study for negative moment. J Struct Eng ASCE 118:2763–278310.1061/(ASCE)0733-9445(1992)118:10(2763) ↗
22. Bae DB, Lee KM (2004) Behavior of preflex beam in manufacturing process. KSCE J Civ Eng 8:111–11510.1007/BF02829086 ↗
23. Metwally AE, Loov RE (2003) Corrugated steel webs for prestressed concrete girders. Mater Struct 36:127–13410.1007/BF02479526 ↗
24. Newman GM (1995) Fire resistance of slim floor beams. J Constr Steel Res 33:87–10010.1016/0143-974X(94)00016-B ↗
25. Ma Z, Mäkeläinen P (1999) Numerical analysis of steel–concrete composite slim floor structures in fire. Laboratory of Steel Structures Publications 11. Helsinki University of Technology, Espoo
26. Ma Z, Mäkeläinen P (2006) Structural behavior of composite slim floor frames in fire conditions. J Constr Steel Res 62:1282–128910.1016/j.jcsr.2006.04.026 ↗
27. Mäkeläinen P, Ma Z (2000) Fire resistance of composite slim floor beams. J Constr Steel Res 54:345–36310.1016/S0143-974X(99)00059-0 ↗
28. Mullett DL (1992) Slim floor design and construction. The Steel Construction Institute (SCI), Ascot, Berks
29. Mullett DL, Lawson RM (1993) Slim floor construction using deep decking. The Steel Construction Institute (SCI), Ascot, Berks
30. Dwaikat MB, Kodur VKR (2008) A numerical approach for modeling the fire induced restraint effects in reinforced concrete beams. Fire Saf J 43:291–30710.1016/j.firesaf.2007.08.003 ↗
31. ENV 1994-1-2, Eurocode 4 (2005) Design of composite steel and concrete structures. Part 1-2: general rules-structural fire design. European Committee for Standardization, Brussels
32. ICC 2012 (2011) International building code commentary, vol 1. International Code Council
33. ASTM (2012) E119 Standard test methods for fire tests of building construction and materials. ASTM International, West Conshohocken
34. KS 2257 (2005) Methods of fire resistance test for elements of building construction. Part 1: general requirements. Korean Standards Association
35. Korea Institute of Construction Technology (KICT), www.kict.re.kr , 2014
36. ENV 1992-1-2, Eurocode 2 (2004) Basis of design and design actions on structures. Part 1-2: Actions on structures exposed to fire. European Committee for Standardization, Brussels
37. ISO 834 (1999) Fire resistance tests—elements of building construction. Part 1: general requirements. International Organization for Standardization
38. Incropera FP, DeWitt DP, Bergman TL, Lavine AS (2011) Introduction to heat transfer, 6th edn. Wiley
39. ENV 1993-1-2, Eurocode 3 (2005) Design of steel structures. Part 1-2: general rules-structural fire design. European Committee for Standardization, Brussels
40. Gales J, Stratford T (2012) New parameters to describe high temperature deformation of prestressing steel determined using digital image correlation. Struct Eng Int’l 22:476–48610.2749/101686612X13363929517730 ↗
41. Bisby L, Gales J, Maluk C (2013) A contemporary review of large-scale non-standard structural fire testing. Fire Sci Rev 2:1–2710.1186/2193-0414-2-1 ↗
42. Kodur VKR, Garlock M, Iwankiw N (2012) Structures in fire: state-of-the-art, research and training needs. Fire Technol 48:825–839. doi: 10.1007/s10694-011-0247-410.1007/s10694-011-0247-4 ↗
43. Beneš M, Štefan R (2015) Hygro-thermo-mechanical analysis of spalling in concrete walls at high temperatures as a moving boundary problem. Int J Heat Mass Transf 85:110–13410.1016/j.ijheatmasstransfer.2015.01.050 ↗
44. Dwaikat MB, Kodur VKR (2009) Hydrothermal model for predicting fire-induced spalling in concrete structural systems. Fire Saf J 44:425–43410.1016/j.firesaf.2008.09.001 ↗
45. Jansson R (2013) Fire spalling of concrete. PhD thesis, KTH Architecture and the Built Environment
46. Gawin D, Pesavento F (2012) An overview of modeling cement based materials at elevated temperatures with mechanics of multi-phase porous media. Fire Technol 48:753–793. doi: 10.1007/s10694-011-0216-y10.1007/s10694-011-0216-y ↗
47. Dwaikat MB, Kodur VKR (2010) Fire induced spalling in high strength concrete beams. Fire Technol 46:251–274. doi: 10.1007/s10694-009-0088-610.1007/s10694-009-0088-6 ↗
48. Franssen JM (2007) User’s manual for SAFIR 2007, a computer program for analysis of structures subjected to fire. Structural Engineering, ArGEnCO, University of Liege, Belgium
49. Hibbitt, Karlsson & Sorensen Inc. (2006) ABAQUS/Standard user’s manual. ABAQUS Version 6.6. Pawtucket, Rhode Island
50. ANSYS (2012) ANSYS user manual, Version 14.0. ANSYS Inc., Cecil Township
51. Stem-Gottfried J, Rein G (2012) Travelling fire for structural design-Part I: literature review. Fire Saf J 54:74–8510.1016/j.firesaf.2012.06.003 ↗
52. Stem-Gottfried J, Rein G (2012) Travelling fire for structural design—part II: design methodology. Fire Saf J 54:74-8510.1016/j.firesaf.2012.06.003 ↗