journal article·2006-04

A Preliminary Investigation into the Partitioning of the Convective and Radiative Incident Heat Flux in Real Fires

P. F. Lennon, G. W. H. Silcock

Fire Technology· Volume 42· Issue 2
Publisher page

Abstract

With the ever present need to increase the understanding of fire and its destructive potential; there is a requirement for instruments capable of accurate measurement coupled with robustness and economy. Heat flux forms a major factor in any fire analysis but there is a lack of suitable flux measuring instrumentation. As a result of an examination of current literature a thin plate heat flux device has been suggested. To determine its capabilities a one third scale ISO fire test compartment was constructed and instrumented to allow comparisons to be made between the proposed plate devices and available total flux gauges and window type Gardon Gauges. Wall and gas temperatures respectively were measured using Aspirated and Type K thermocouples. The analysis of data from over 30 tests proved encouraging in that the new instrumentation yielded realistic results when compared with radiative Gardon Gauge and total flux gauge output. Experimental analysis conducted so far suggests that the plate device may provide a robust economic and relatively accurate means of heat flux measurement and partitioning.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire dynamics and safety research · Fire Detection and Safety Systems · Combustion and Detonation Processes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (19)

Show source-provided references
1. S.H. Ingberg, “Tests of Severity of Building Fires,” US National Fire Protection Association Quarterly, vol. 22, 1928, pp. 43–61.
2. E.G. Butcher, T.B. Chitty, and L.A. Ashton, “The Temperature Attained by Steel in Building Fires,” Fire Research Technical Paper No.15, 1966.
3. D. Gross, “Measurements of Fire Loads and calculations of Fire Severity”, National Bureau of Standards, Gaithburg MD wood and fibre, vol. 9, no.1. 1977.
4. T.Z. Harmathy, Fire Safety Design and Concrete, John Wiley and Sons Ltd. 1993.
5. T.J. Shields and G.W.H. Silcock, Buildings and Fire, Longman Scientific and Technical, 1987.
6. D. Gross and A.F. Robertson, “Experimental Fires in Enclosures,” in 10th Symposium International on Combustion, Combustion Institute Pittsburgh, 1965, pp. 931–942.10.1016/S0082-0784(65)80236-3 ↗
7. D.J. O’Connor, B. Morris, and G.W.H. Silcock, “Flux Measurement in Real and Standard Fires,” Part1: BRE Fire Programme, 1997.10.1201/9781482294965-3 ↗
8. C.H. Kuo and A.K. Kulkarni, “Analysis of Heat Flux Measurement by Circular Foil Gauges in a Mixed Convection/Radiation Environment,” Journal of Heat Transfer, vol. 113, Part 4, 1991, pp. 1037–1040.10.1115/1.2911202 ↗
9. A.F. Robertson and T.J. Ohlemiller, “Low Heat-flux Measurements: Some Precautions”, Fire Safety Journal, vol. 25, 1995, pp. 109–124.10.1016/0379-7112(95)00036-4 ↗
10. U. Wickstrom, “The Plate Thermometer. A Simple Instrument for Reaching Harmonised Fire Resistance Tests,” NORDTEST project 609-86, Fire Technology SP Report: 03, 1989.
11. B.Y. Lattimer, L.W. Langely, and U. Vandsburger, “Detecting Fires using a Thin-Film Heat Flux Microsensor,” ASME-Heat Transfer Division, Proceedings HTD-vol. 296, 1994, pp. 137–142.
12. P.F. Lennon, and G.W.H. Silcock, “An Investigation of the Ability of a Thin Plate Heat Flux Device to Determine the Incident Heat Fluxes during Enclosure Fires,” International Journal on Engineering Performance-Based Fire Codes, vol. 3, no. 1, 2001, pp. 1–15.
13. M. Luo, “Effects of Radiation on Temperature Measurement in a Fire Environment”, Journal of Fire Sciences, vol. 15, 1997, pp. 443–461.10.1177/073490419701500602 ↗
14. C. Clarke, “Higher National Certificate Project on Aspirated Thermocouples,” School of the Built Environment, University of Ulster, 1998.
15. P.R.N. Childs, J.R. Greenwood, and C.A. Long, “Heat Flux Measurement Techniques”, Proceedings of the Institution of Mechanical Engineers, vol. 213, Part C, 1999, pp. 655–677.
16. N. Keltner, “Thermal Measurements in Fire Safety Testing – Are we Playing with Fire,” Ktech Corporation, Albuquerque, New Mexico.
17. D. Holmberg, and C.A. Womeldorf, “Report on the First-Generation NIST Convective Heat Calibration Facility,” NISTIR 6197, USA Department of Commerce Technology Administration, 1998.10.6028/NIST.IR.6197 ↗
18. E.D. Dillon, “Analysis of the ISO 9705 Room/Corner Test: Simulations, Correlations and Heat Flux Measurements”, NIST-GCR-98-756, USA Dept. of Commerce Technology Administration, 1998, p. 151.
19. ASTME, “Standard Guide for Room Fire Experiments,” American Society for Testing and Materials, January 10th, 1997, pp. 603–697.