journal article·2001-07

Estimating Water Requirements for Firefighting Operations Using FIERAsystem

David Torvi, George Hadjisophocleous, Matthew B. Guenther, Gordon Thomas

Fire Technology· Volume 37· Issue 3
Publisher page

Abstract

A new computer model for estimating water requirements for firefighting purposes has been developed by the Fire Risk Management Program of the National Research Council of Canada. This work was done in partnership with the Canadian Department of National Defence, as part of the development of a computer model to evaluate fire protection systems in light industrial buildings (FIERAsystem). The new model considers the geometry of the building, possible fire scenarios that may occur in the building, fire detector locations and characteristics, the effect of automatic suppression systems on the fire, the locations of adjacent buildings and the response and effectiveness of the fire department. The program calculates the required flow rates of water at the time of fire department intervention for suppression of the fire and for exposure protection for each side of the building. These flow rates can then be compared to the total capacity of the fire engines available to determine if existing resources are sufficient. The program has been designed to be interactive, so that the user can immediately see the effects of various parameters on the required water flow rate. Descriptions of case studies are also included to demonstrate the use of this model.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire dynamics and safety research · Wind and Air Flow Studies · Evacuation and Crowd Dynamics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (16)

Show source-provided references
1. G.C. Anderson, “ISO Commercial Risk Services,” AWWA Seminar Proceedings—Fire Protection, American Water Works Association, Denver, CO, June, 1986.
2. K.W. Linder, “Water Supply Requirements For Fire Protection,” Fire Protection Handbook, 17th ed., Quincy, MA: National Fire Protection Association, 1981.
3. K. Royer, W.N. Floyd, “Water For Fire Fighting—Rate-of-Flow Formula,” Iowa State University Bulletin, Engineering Extension—Bulletin No. 18, Iowa State University, Ames, IA.
4. A.H. Buchanan, (ed.), Fire Engineering Design Guide, Centre for Advanced Engineering, University of Canterbury, New Zealand, 1994.
5. “Fire Protection Water Supply Guideline for Part 3 in the Ontario Building Code,” Office of the Fire Marshal Technical Guideline OFM-TG-07-96, Province of Ontario, North York, ON, 1996.
6. NFPA 1231: Standard on Water Supplies for Suburban and Rural Fire Fighting, Quincy, MA: National Fire Protection Association, 1993.
7. K.J. Carl et al., “GuidelinesF or Determining Fire-Flow Requirements,” Journal of the American Water Works Association, May 1973, pp. 335–344.10.1002/j.1551-8833.1973.tb01845.x ↗
8. G.V. Hadjisophocleous, D.A. Torvi, Z. Fu, and B. Yager, “FIERAsystem: A Computer Model for Fire Evaluation and Risk Assessment,” Proceedings, ASME Offshore Mechanics and Arctic Engineering (OMAE) 18th International Conference, July 11–16, 1999, St. John's, NF, Paper Number OMAE99-6016.
9. SFPE Handbook of Fire Protection Engineering, Quincy, MA: National Fire Protection Association, 1995.
10. S. Särdqvist, An Engineering Approach to Fire-Fighting Tactics, Report 1014, Department of Fire Safety Engineering, Lund University, Sweden, 1996.
11. National Building Code of Canada 1995, Canadian Commission on Building and Fire Codes, National Research Council of Canada, Ottawa, ON, 1995.
12. J.H. McGuire, “Fire and the Spatial Separation of Buildings,” Fire Technology, vol. 1, 1965, pp. 278–287.10.1007/BF02588470 ↗
13. G. Williams-Leir, “Approximations for Spatial Separation,” Fire Technology, vol. 2, 1966, pp. 136–145.10.1007/BF02588542 ↗
14. G. Williams-Leir, “Another Approximation for Spatial Separation,” Fire Technology, vol. 6, 1970, pp. 189–202.10.1007/BF02588918 ↗
15. NFPA 80A: Recommended Practice for Protection of Buildings from Exterior Fire Exposures, Quincy, MA: National Fire Protection Association, 1993.
16. NFPA 92B: Guide for Smoke Management Systems in Malls, Atria, and Large Areas, Quincy, MA: National Fire Protection Association, 1995.