journal article·2010-01

Effect of Aspect Ratio on Fire Resistance of Hollow Core Concrete Floors

Jeremy J. Chang, Peter J. Moss, Rajesh P. Dhakal, Andrew H. Buchanan

Fire Technology· Volume 46· Issue 1
Publisher page

Abstract

Several factors can affect the behaviour of the hollowcore floor slabs in fire. This paper analytically investigates the relationship between the fire resistance of the overall floor system and the floor length to width ratio as well as the type of side supports. The study uses beam grillage and shell elements to model the hollowcore slabs and the topping concrete under the platform of the non-linear finite element program, SAFIR. Different methods to model precast, prestressed concrete hollowcore floor slabs subjected to fire are also investigated. The results show that side supports can enhance the fire performance of hollowcore floor slabs provided that the spacing of the side supports does not greatly exceed the span length.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire effects on concrete materials · Structural Behavior of Reinforced Concrete · Fire dynamics and safety research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (13)

Show source-provided references
1. Fellinger JHH (2004) Shear and anchorage behaviour of fire exposed hollowcore slabs. DUP Science, the Netherlands
2. Fib (1998) Résistance au Cisaillement de Dalles Alvéolées Précontraintes. Studiecommissie SSTC, University of Liège, Belgium
3. BEF Hollow Core Slabs and Fire (2005) Documentation on shear capacity. Birch and Krogboe A/S, Denmark
4. Chang J, Buchanan AH, Dhakal RP, Moss PJ (2008) Hollowcore concrete slab exposed to fire. Fire Mater. Online ISSN: 1099-1018
5. EC2 (2002) Eurocode 2: design of concrete structures. PrEN 1992-1-2: general rules—structural fire design. CEN, Brussels
6. BSI Precast Concrete Products (1995) Hollow core slabs. BS EN1168, British Standards Institution, London
7. SNZ (2006) The design of concrete structures. NZS 3101, Standards New Zealand, Wellington
8. Franssen JM, Kodur VKR, Mason J (2002) User’s manual for SAFIR2001 free: a computer program for analysis of structures at elevated temperature conditions. University of Liège, Belgium
9. EC3 (2002) Eurocode 3: design of steel structures. PrEN 1993-1-2: general rules—structural fire design. CEN, Brussels
10. Chang J (2007) Computer simulation of hollowcore concrete floor systems exposed to fire. PhD Thesis, University of Canterbury, Christchurch
11. fib (1998) Résistance au Cisaillement de Dalles Alvéolées Précontraintes. Studiecommissie SSTC, Belgium
12. Firth Stresscrete and Stahlton (2007) Flooring precast concrete manual 2007. Firth Stresscrete, Porirua
13. Lennon T (2007) The need for large scale fire tests. Fib workshop: Fire Design of Concrete Structures, Coimbra, Portugal