Fire Resistance of Steel C-Joist Floor Assemblies
Source abstract
Abstract
This paper discusses the factors that affect the fire resistance performance of lightweight steel-framed (LSF) unrestrained floor assemblies protected with Type X gypsum board ceiling finishes. Sixteen fire resistance experiments were conducted on full-scale load-bearing steel C-joist floor assemblies using the ULC standard fire exposure time–temperature curve that is similar to ASTM E119 standard. Parameters investigated in this study include the effects of insulation installation, insulation type, joist spacing, resilient channel installation, resilient channel spacing, type of sub-floor layer and number of sub-floor layers versus number of gypsum board layers. The impact of these parameters on the fire resistance of steel C-joist frame floor assemblies is discussed. The fire resistance of LSF floors appears to be essentially governed by the number of gypsum board layers, spacing of the joists or resilient channels where the gypsum boards are attached, sub-floor type and insulation type. Other parameters are of secondary importance.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire effects on concrete materials · Fire dynamics and safety research · Structural Response to Dynamic Loads
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (13)
Show source-provided references
1. National Building Code of Canada (Part 9) (1995) National Research Council of Canada, Ottawa, ON
2. Sultan MA, Seguin YP Leroux P (1998) Results of fire resistance tests on full-scale floor assemblies, Internal Report No. 764, Institute for Research in Construction, National Research Council of Canada, Ottawa, ON
3. Sultan MA, Latour JC, Leroux P, Monette RC, Seguin YP, Henrie J (2005) Results of fire resistance tests on full-scale floor assemblies—phase II, Research Report 184. Institute for Research in Construction, National Research Council Canada, Ottawa, Ontario
4. CAN/ULC-S101-M89 (1989) Standard methods of fire endurance tests of building construction and materials. Underwriters’ Laboratories of Canada, Scarborough, ON
5. ASTM E119-88 (1988) Standard test method for fire tests of building construction and materials. ASTM, West Conshohocken, PA
6. Alfawakhiri F, Sultan MA (2001) Load bearing capacity of cold framed steel joists subjected to severe heating. In: Proceedings of the ninth international interflame conference. Interscience Communications Limited, West Yard House, Guildford, Greenwich, London, SE10 8JT, England
7. CAN/CSA-A82 31-M91 (1991) Gypsum board application. Canadian Standards Association, Rexdale, ON
8. CSA A101-M83 (1983) Thermal insulation. Canadian Standards Association, Rexdale, Ontario
9. CAN/ULC-S702-M97 (1997) Standard for mineral fibre thermal insulation for buildings. Underwriters’ Laboratories of Canada, Scarborough, Ontario
10. CAN/CGSB 51.60-M90 (1990) Cellulose fibre loose fill thermal insulation. Canadian Standards Board, Ottawa, Ontario
11. CAN/CSA-82 27-M91 (1991) Gypsum board. Canadian Standards Association, Etobicoke, Ontario, Canada
12. ASTM C36-97 (1997) Standard specification for gypsum wallboard. American Society for Testing and Materials, West Conshohocken, PA, June
13. Shorter GW, Harmathy TZ (1960) Fire research furnaces at the National Research Council, NRC 5732. National Research Council of Canada, Ottawa, Ontario