journal article·2021-07Open access

Review of Research on the Fire Behavior of Simple Shear Connections

Erica C. Fischer, Rachel Chicchi, Lisa Choe

Fire Technology· Volume 57· Issue 4

Abstract

Previous building fires and research has shown that simple (shear) connections develop large axial force and flexural demands during a fire leading to potential failure of the connections and progressive collapse of a building. These findings have motivated decades of international research on the fire behavior of simple (shear) connections. While this research all confirmed that simple connections experience large axial force and flexural demands, it occurred without consistency of testing methodology, testing setup, and reporting of results. Due to this inconsistency, the decades of research have yet to be synthesized into comprehensive code changes for the design of simple connections in fires. This paper will summarize international experimental and numerical research on simple (shear) connections and highlight the inconsistencies between this research in an effort to motivate consistent testing and data reporting for future research developments.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire effects on concrete materials · Fire dynamics and safety research · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (38)

Show source-provided references
1. McAllister TP, Gann RG, Averill JD, Gross JL, Grosshandler WL, Lawson JR, McGrattan KB, Pitts WM, Prasad KR, Sadek FH (2008) Structural fire response and probably collapse sequence of world trade center building 7. National Institute of Standards and Technology (NIST), Gaithersburg
2. Lennon T, Moore D (2003) The natural fire safety concept—full-scale tests at Cardington. Fire Saf J 38:623–64310.1016/S0379-7112(03)00028-6 ↗
3. AISC (2016) Specification for structural steel buildings (ANSI/AISC 2016). American Institute of Steel Construction (AISC), Chicago
4. ASCE (2016) Minimum design loads for buildings and other structures (ASCE 7–16). American Society of Civil Engineers (ASCE), Reston
5. City of New York (2014) New York City building code, City of New York,: New York, NY
6. CEN (2005) Eurocode 3: design of steel structures—Part 1–2: general rules—structural fire design. European Committee for Standardization (CEN), Brussels
7. Sarraj M, Burgess IW, Davison J, Plank RJ (2007) Finite element modeling of steel fin plate connections in fire. Fire Saf J 42(6–7):408–41510.1016/j.firesaf.2007.01.007 ↗
8. Garlock ME, Selamet S (2010) Modeling and behavior of steel plate connections subject to various fire scenarios. J Struct Eng 136(7):897–90610.1061/(ASCE)ST.1943-541X.0000179 ↗
9. Selamet S, Garlock ME (2010) Robust fire design of single plate shear connections. Eng Struct 32:2367–237810.1016/j.engstruct.2010.04.011 ↗
10. Hu G, Engelhardt MD (2011) Investigations on the behavior of steel single plate beam end framing connections in fire. J Struct Fire Eng 2(3):195–20410.1260/2040-2317.2.3.195 ↗
11. Pakala P, Kodur V (2013) System-level approach to predict the transient fire response of double angle connections. J Constr Steel Res 89:132–14410.1016/j.jcsr.2013.06.007 ↗
12. Hantouche EG, Abboud NH, Morovat MA, Engelhardt MD (2016) Analysis of steel bolted double angle connections at elevated temperatures. Fire Saf J 83:78–8910.1016/j.firesaf.2016.05.002 ↗
13. Fischer EC, Varma AH (2017) Fire resilience of composite beams with simple connections: parametric studies and design. J Constr Steel Res 128:119–13510.1016/j.jcsr.2016.08.004 ↗
14. Lawson RM (1990) Behaviour of steel beam-to-column connections in fire. Struct Eng 68:263–271
15. Leston-Jones LC, Lennon T, Plank RJ, Burgess IW (1997) Elevated temperature moment-rotation tests on steelwork connections. Proc Inst Civ Eng Struct Bldgs 122:410–41910.1680/istbu.1997.29830 ↗
16. Al-Jabri KS, Lennon T, Burgess IW, Plank RJ (1998) Behaviour of steel and composite beam-column connections in fire. J Constr Steel Res 46:1–310.1016/S0143-974X(98)00059-5 ↗
17. Liu TCH, Fahad MK, Davies JM (2002) Experimental investigation of behaviour of axially restrained steel beams in fire. J Constr Steel Res 58(9):1211–123010.1016/S0143-974X(01)00062-1 ↗
18. Yu H, Burgess IW, Davison JB, Plank RJ (2009) Experimental investigation of the behaviour of fin plate connections in fire. J Constr Steel Res 65:723–73610.1016/j.jcsr.2008.02.015 ↗
19. Wang YC, Dai XH, Bailey CG (2011) An experimental study of relative structural fire behaviour and robustness of different types of steel joint in restrained steel frames. J Constr Steel Res 67:1149–116310.1016/j.jcsr.2011.02.008 ↗
20. Pakala P, Kodur V, Selamet S, Garlock M (2012) Fire behavior of shear angle connections in a restrained steel frame. J Constr Steel Res 77:119–13010.1016/j.jcsr.2012.05.006 ↗
21. Fischer EC, Selden KL, Varma AH (2016) Experimental evaluation of the fire performance of simple connections. J Struct Eng 143(2):0401618110.1061/(ASCE)ST.1943-541X.0001664 ↗
22. Choe L, Ramesh S, Hoehler M et al (2019) Compartment fire experiments on long-span composite beams with simple shear connections part 2: test results. National Institute of Standards and Technology (NIST) Tech Note, TN 2055, Gaithersburg, MD10.6028/NIST.TN.2055 ↗
23. Kordosky AN, Drury MM, Quiel SE (2020) Structural fire resistance of partially restrained, partially composite floor beams, I: experiments. J Constr Steel Res 167:10594510.1016/j.jcsr.2020.105945 ↗
24. da Silva LS, Santiago A, Vila Real P, Moore D (2005) Behaviour of steel joints under fire loading. Steel Compos Struct 5(6):485–51310.12989/scs.2005.5.6.485 ↗
25. Spyrou S, Davison JB, Burgess IW, Plank RJ (2004) Experimental and analytical investigation of the ‘tension zone’ components within a steel joint at elevated temperatures. J Constr Steel Res 60:867–89610.1016/j.jcsr.2003.10.006 ↗
26. Spyrou S, Davison JB, Burgess IW, Plank RJ (2004) Experimental and analytical investigation of the ‘compression zone’ components within a steel joint at elevated temperatures. J Constr Steel Res 60:841–86510.1016/j.jcsr.2003.10.005 ↗
27. ISO (2014) Fire resistance tests—elements of building construction—Part 11: Specific requirements for the assessment of fire protection to structural steel elements (ISO 834-11:2014). International Organization for Standardization, Geneva
28. Wald F, Simos da Silva L, Moore DB, Lennon T, Chladna M, Santiago A, Benes M, Borges L (2006) Experimental behaviour of a steel structure under natural fires. Fire Saf J 41:509–52210.1016/j.firesaf.2006.05.006 ↗
29. ASTM (2018) Standard test methods for fire tests of building construction and materials (ASTM E119–20). ASTM, West Conshohocken
30. Fischer EC, Varma AH (2015) Fire behavior of composite beams with simple connections: benchmarking of numerical models. J Constr Steel Res 111:112–12510.1016/j.jcsr.2015.03.013 ↗
31. Choe L, Ramesh S, Hoehler M et al (2020) Behavior and limit states of long-span composite floor beams with simple shear connections subject to compartment fires: experimental evaluation. J Struct Eng 146(6):0402008810.1061/(ASCE)ST.1943-541X.0002627 ↗
32. ICC (2018) International Building Code. International Code Council, Washington
33. Drury MM, Kordosky AN, Quiel SE (2020) Structural fire resistance of partially restrained, partially composite floor beams, II: modeling. J Constr Steel Res 167:10594610.1016/j.jcsr.2020.105946 ↗
34. Kirby BR (1997) Large scale fire tests: the British steel European collaborative research programme on the Bre 8-storey frame. Fire Saf Sci 5:1129–114010.3801/IAFSS.FSS.5-1129 ↗
35. Wang YC (2000) An analysis of the global structural behaviour of the Cardington steel-framed building during the two BRE fire tests. Eng Struct 22:401–41210.1016/S0141-0296(98)00127-8 ↗
36. Wald F, Sokol Z, Moore D (2009) Horizontal forces in steel structures tested in fire. J Constr Steel Res 65:1896–190310.1016/j.jcsr.2009.04.020 ↗
37. Choe L, Ramesh S, Dai X et al (2020) Experimental study on fire resistance of a full-scale composite floor assembly in a two-story steel framed building. In: Proceedings of the 11th international conference on structures in fire, November 30–December 2, 2020, University of Queensland, Brisbane, Australia10.14264/e6af102 ↗
38. Dai X, Choe L, Fischer E, Clifton C (2020) Thermal response and capacity of beam end shear connections during a large compartment fire experiment. In: Proceedings of the 11th international conference on structures in fire, November 30–December 2, 2020, University of Queensland, Brisbane, Australia10.14264/479d2dd ↗