journal article·2016-11

Simulation of an Attic Fire in a Wood Frame Residential Structure, Chicago, IL

Craig G. Weinschenk, Kristopher J. Overholt, Daniel Madrzykowski

Fire Technology· Volume 52· Issue 6
Publisher page

Abstract

The fire dynamics simulator (FDS) fire model, which is developed and maintained by the National Institute of Standards and Technology (NIST), was used to provide insight into the dynamics of a fire that occurred on November 2, 2012, within a 2 ½ story, single family structure in Chicago, IL, that resulted in the death of the captain of a fire department. The inputs for the FDS simulations are documented in this report and are based on the fire scenario, including the building geometry, interior furnishings, and ventilation conditions. The fire started in the attic and spread down through an opening into the enclosed porch on the rear of the structure. This resulted in ventilation limited (fuel rich) fire conditions in the attic and rear porch areas. Further spread of fire and hot gases from the attic downward into the second floor of the structure was limited by a closed steel-faced, wood-framed door. Note that there was no evidence of fire damage on the first floor of the structure. After exposure to the elevated temperatures and pressure from the fire in the porch area, the wood frame of the door decomposed, the steel faces of the door failed, and the door collapsed inward. The door failure resulted in the establishment of a flow path between the higher pressure and higher temperature conditions in the enclosed porch and the lower pressure and lower temperature conditions in the hallway and kitchen areas of the second floor. The temperature of the gases that flowed into the hallway exceeded 260°C (500°F) at a height of 1.86 m (6 ft). Unfortunately, a captain and firefighter were advancing a hose line in the hallway near the door at the time of the door failure. It appears that the captain was likely overcome by the rapid change in conditions before he could exit to the safety of the kitchen area. After a Mayday call, the captain was rescued from the structure, but later succumbed to his injuries.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire dynamics and safety research · Fire effects on ecosystems · Evacuation and Crowd Dynamics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (48)

Show source-provided references
1. Madrzykowski D, Vettori R (2000) Simulation of the dynamics of the fire at 3146 Cherry Road NE Washington D.C., May 30, 1999. NISTIR 6510, National Institute of Standards and Technology, Gaithersburg10.6028/NIST.IR.6510 ↗
2. Madrzykowski D, Forney G, Walton W (2002) Simulation of the dynamics of a fire in a two-story duplex—Iowa, December 22, 1999. NISTIR 6854, National Institute of Standards and Technology, Gaithersburg10.6028/NIST.IR.6854 ↗
3. Vettori R, Madrzykowski D, Walton W (2002) Simulation of the dynamics of a fire in a one-story restaurant—Texas, February 14, 2000. NISTIR 6923, National Institute of Standards and Technology, Gaithersburg
4. Bryner N, Fuss S, Klein B, Putorti A (2011) Technical study of the sofa super store fire, South Carolina, June 18, 2007. NIST Special Publication 1118, National Institute of Standards and Technology, Gaithersburg10.6028/NIST.SP.1119v2 ↗
5. Barowy A, Madrzykowski D (2012) Simulation of the dynamics of a wind-driven fire in a ranch-style house— Texas. NIST Technical Note 1729, National Institute of Standards and Technology, Gaithersburg
6. McGrattan K, Hostikka S, McDermott S, Floyd J, Weinschenk C, Overholt K (2013) Fire dynamics simulator, user’s guide. Gaithersburg, National Institute of Standards and Technology, and VTT Technical Research Centre of Finland, Espoo, Finland, sixth edn
7. Forney G (2013) Smokeview (Version 6), a tool for visualizing fire dynamics simulation data, volume i: user’s guide. NIST Special Publication 1017-1, National Institute of Standards and Technology, Gaithersburg10.6028/NIST.SP.1017-1 ↗
8. Weinschenk C, Overholt K, Madrzykowski D (2014) Simulation of an attic fire in a wood frame residential structure—Chicago, IL. NIST Technical Note 1838, National Institute of Standards and Technology, Gaithersburg10.6028/NIST.TN.1838 ↗
9. Bowyer M, Wertman S, Loflin M (2013) Career captain sustains injuries at a 2-1/2 story apartment fire then dies at hospital—Illinois. NIOSH F2012-28, NIOSH Fire Fighter Fatality Investigation and Prevention Program
10. McGrattan K, Hostikka S, McDermott R, Floyd J, Weinschenk C, Overholt K (2013) Fire dynamics simulator, technical reference guide, volume 2: verification. Gaithersburg, National Institute of Standards and Technology, and VTT Technical Research Centre of Finland, Espoo, Finland, sixth edn10.6028/NIST.SP.1018e6 ↗
11. McGrattan K, Hostikka S, McDermott R, Floyd J, Weinschenk C, Overholt K (2013) Fire dynamics simulator, technical reference guide, volume 3: validation. Gaithersburg, National Institute of Standards and Technology, and VTT Technical Research Centre of Finland, Espoo, Finland, sixth edn10.6028/NIST.SP.1018e6 ↗
12. McGrattan K, Hostikka S, McDermott R, Floyd J, Weinschenk C, Overholt K (2013) Fire dynamics simulator, technical reference guide, volume 1: mathematical model. Gaithersburg, National Institute of Standards and Technology, and VTT Technical Research Centre of Finland, Espoo, Finland, sixth edn10.6028/NIST.SP.1018e6 ↗
13. SFPE (2011) SFPE G.06, guidelines for substantiating a fire model for a given application. Society of Fire Protection Engineers, Bethesda
14. Tewarson A (2008) Generation of heat and gaseous, liquid, and solid products. SFPE handbook of fire protection engineering, 4th edn. National Fire Protection Association, Quincy
15. Babrauskas V, Grayson S (1990) Heat release in fires. Taylor & Francis, London
16. ASTM E 1355-04 (2004) Standard guide for evaluating the predictive capabilities of deterministic fire models. American Society for Testing and Materials, West Conshohocken
17. McGrattan K, Hostikka S, McDermott R, Floyd J, Weinschenk C, Overholt K (2013) Fire dynamics simulator, technical reference guide. Gaithersburg, National Institute of Standards and Technology, and VTT Technical Research Centre of Finland, Espoo, Finland, sixth edn. Vol. 1: Mathematical Model; Vol. 2: Verification Guide; Vol. 3: Validation Guide; Vol. 4: Configuration Management Plan10.6028/NIST.SP.1018e6 ↗
18. Ghazi Wakili K, Hugi E, Wullschleger L, Frank T (2007) Gypsum board in fire. Modelling and experimental validation. J Fire Sci 25(3):26710.1177/0734904107072883 ↗
19. Incropera FP, De Witt DP (1996) Fundamentals of heat and mass transfer, 4th edn. Wiley, New York
20. Beal CM, Fakhreddine M, Ezekoye OA (2009) Effects of leakage in simulations of positive pressure ventilation. Fire Technol 45(3):257. doi: 10.1007/s10694-008-0055-710.1007/s10694-008-0055-7 ↗
21. Hill K, Dreisbach J, Joglar F, Najafi B, McGrattan K, Peacock R, Hamins A (2007) Verification and validation of selected fire models for nuclear power plant applications. NUREG-1824, United States Nuclear Regulatory Commission, Washington
22. Jahn W, Rein G, Torero J (2008) Proceedings of the ninth symposium on fire safety science. Karlsruhe, Germany. http://hdl.handle.net/1842/2696
23. Gutiérrez-Montes C, Sanmiguel-Rojas E, Viedma A, Rein G (2009) Experimental data and numerical modelling of 1.3 and 2.3 MW fires in a 20 m cubic atrium. Build Environ 44:1827. http://hdl.handle.net/1842/276110.1016/j.buildenv.2008.12.010 ↗
24. Rein G, Abecassis Empis C, Carvel R (eds) (2007) The dalmarnock fire tests: experiments and modelling. University of Edinburgh, Edinburgh
25. Rein G, Torero J, Jahn W, Stern-Gottfried J, Ryder N, Desanghere S, Läzaro M, Mowrer F, Coles A, Joyeux D, Alvear D, Capote J, Jowsey A, Abecassis-Empis C, Reszka P (2009) Round-robin study of a priori modelling predictions of the Dalmarnock Fire Test One. Fire Saf J 44(4):590 (2009). http://hdl.handle.net/1842/270410.1016/j.firesaf.2008.12.008 ↗
26. Xiao B (2012) Comparison of numerical and experimental results of fire induced doorway flows. Fire Technol 48(3):595. doi: 10.1007/s10694-009-0131-710.1007/s10694-009-0131-7 ↗
27. Walton W, Thomas P (2008) Estimating temperatures in compartment fires. SFPE handbook of fire protection engineering, 4th edn. National Fire Protection Association, Quincy
28. Stroup D, Lindeman A (2013) Verification and validation of selected fire models for nuclear power plant applications. NUREG-1824, Supplement 1, United States Nuclear Regulatory Commission, Washington
29. Heskestad G (2008) Fire plumes, flame height and air entrainment. SFPE handbook of fire protection engineering, 4th edn. National Fire Protection Association, Quincy
30. ASTM C 1055-03 (2003) Standard guide for heated system surface conditions that produce contact burn injuries. American Society for Testing and Materials, West Conshohocken
31. Mensch A, Bryner N (2011) Emergency first responder respirator thermal characteristics: workshop proceedings. NIST Special Publication 1123, US Department of Commerce, Engineering Laboratory, National Institute of Standards and Technology, Washington10.6028/NIST.SP.1123 ↗
32. NFPA 1971 (2013) Standard on protective ensembles for structural fire fighting and proximity fire fighting. National Fire Protection Association, Quincy
33. Pettit T, Washenitz F, Cortez K (1999) Three fire fighters die in a 10-story high-rise apartment building—New York. NIOST 99-F01, NIOSH Fire Fighter Fatality Investigation and Prevention Program
34. Washenitz F, Braddee R, Pettit T, Schmidt E (1999) Two fire fighters die and two are injured in townhouse fire—District of Columbia. NIOSH 99-F21, NIOSH Fire Fighter Fatality Investigation and Prevention Program
35. Mezzanotte T, Schmidt E, Pettit T, Castillo D (2001) Structure fire claims the lives of three career fire fighters and three children—Iowa. NIOSH F2000-04, NIOSH Fire Fighter Fatality Investigation and Prevention Program
36. McFall M, Schmidt E (2001) Arson fire claims the life of one volunteer fire fighter and one civilian and severely injures another volunteer fire fighter—Michigan. NIOSH F2000-16, NIOSH Fire Fighter Fatality Investigation and Prevention Program
37. McFall M, Braddee R, Mezzanotte T (200) Career fire fighter dies and three are injured in a residential garage fire—Utah. NIOSH F2000-23, NIOSH Fire Fighter Fatality Investigation and Prevention Program
38. McFall M (2001) A volunteer assistant chief was seriously injured and two volunteer fire fighters were injured while fighting a townhouse fire—Delaware. NIOSH F2000-43, NIOSH Fire Fighter Fatality Investigation and Prevention Program
39. Berardinelli S, Oerter B, Tarley J, Merinar T (2006) Career battalion chief and career master fire fighter die and twenty—nine career fire fighters are injured during a five alarm church fire—Pennsylvania. NIOSH F2004-02, NIOSH Fire Fighter Fatality Investigation and Prevention Program
40. Koedam R, Merinar T, Bowyer M (2007) One probationary career firefighter dies and four career firefighters are injured at a two-alarm residential structure fire—Texas. NIOSH F2005-02, NIOSH Fire Fighter Fatality Investigation and Prevention Program
41. McFall M, Lutz V, Berardinelli S (2006) Career fire fighter dies while exiting residential basement fire—New York. NIOSH F2005-04, NIOSH Fire Fighter Fatality Investigation and Prevention Program
42. Tarley J, Berardinelli S, Merinar T (2008) Career probationary fire fighter dies while participating in a live—fire training evolution at an acquired structure—Maryland. NIOSH F2007-09, NIOSH Fire Fighter Fatality Investigation and Prevention Program
43. Braddee R, Bowyer M, Berardinelli S (2008) Four career fire fighters injured while providing interior exposure protection at a row house fire—District of Columbia. NIOSH F2007-35, NIOSH Fire Fighter Fatality Investigation and Prevention Program
44. Merinar T, Tarley J, Miles S (2010) Career probationary fire fighter and captain die as a result of rapid fire progression in a wind-driven residential structure fire—Texas. NIOSH F2009-11, NIOSH Fire Fighter Fatality Investigation and Prevention Program
45. Bowyer M, Loflin M (2012) A career lieutenant and fire fighter/paramedic die in a hillside residential house fire—California. NIOSH F2011-13, NIOSH Fire Fighter Fatality Investigation and Prevention Program
46. Loflin M, Hales T, Miles S (2013) Career fire fighter dies during fire-fighting operations at a multi-family residential structure fire—Massachusetts. NIOSH F2011-31, NIOSH Fire Fighter Fatality Investigation and Prevention Program
47. Madrzykowski D, Kerber S (2009) Fire fighting tactics under wind driven conditions: laboratory experiments. NIST Technical Note 1618, National Institute of Standards and Technology, Fire Research Division Engineering Laboratory10.6028/NIST.TN.1618 ↗
48. Kerber S, Madrzykowski D (2009) Fire fighting tactics under wind driven fire conditions: 7-story building experiments. NIST Technical Note 1629, National Institute of Standards and Technology, Fire Research Division Engineering Laboratory10.6028/NIST.TN.1629 ↗