Ultimate Behavior of Idealized Composite Floor Elements at Ambient and Elevated Temperature
Source abstract
Abstract
This paper is concerned with the ultimate behavior of composite floor slabs under extreme loading situations resembling those occurring during severe building fires. The study focuses on the failure state associated with rupture of the reinforcement in idealized slab elements, which become lightly reinforced in a fire situation due to the early loss of the steel deck. The paper describes a fundamental approach for assessing the failure limit associated with reinforcement fracture in lightly reinforced beams, representing idealized slab strips. A description of the ambient-temperature tests on isolated restrained elements, carried out to assess the influence of key material parameters on the failure conditions, is firstly presented. The results of a series of material tests, undertaken mainly to examine the effect of elevated temperature on ductility, are also described. A simplified analytical model is employed, in conjunction with the experimental findings, to assess the salient material parameters and their implications on the ultimate response at both ambient and elevated temperature.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire effects on concrete materials · Structural Response to Dynamic Loads · Fire dynamics and safety research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (17)
Show source-provided references
1. Wang YC, Lennon T, Moore DB (1995) The behaviour of steel frames subject to fire. J Constr Steel Res 35:291–322. doi: 10.1016/0143-974X(94)00046-K10.1016/0143-974X(94)00046-K ↗
2. Huang Z, Burgess IW, Plank RJ (1999) Nonlinear analysis of reinforced concrete slabs subjected to fire. Am Concr Inst Struct J 96(1):127–135
3. Bailey CG, Moore DB (2000) The structural behavior of steel frames with composite floor slabs subject to fire Part 1: theory. Struct Eng 78(11):19–27
4. Bailey CG, Moore DB (2000) The structural behavior of steel frames with composite floor slabs subject to fire Part 2: design. Struct Eng 78(11):28–33
5. Gillie M, Usmani AS, Rotter JM (2001) A structural analysis of the first Cardington test. J Constr Steel Res 57:581–601. doi: 10.1016/S0143-974X(01)00004-910.1016/S0143-974X(01)00004-9 ↗
6. Elghazouli AY, Izzuddin BA (2001) Analytical assessment of the structural performance of composite floors subject to compartment fires. Fire Saf J 36:769–793. doi: 10.1016/S0379-7112(01)00039-X10.1016/S0379-7112(01)00039-X ↗
7. Lim L, Buchanan A, Moss P (2003) Experimental testing and numerical modelling of two-way concrete slabs under fire conditions. J Struct Eng Soc NZ SESOC 2–26
8. O’Connor MA, Martin DM (1998) Multi-storey steel framed building subjected to subjected to fire attack. J Constr Steel Res 46(1):Paper 169
9. Izzuddin BA, Elghazouli AY (2004) Failure of lightly reinforced concrete members under fire. I: analytical modeling. J Struct Eng 130(1):3–17. doi: 10.1061/(ASCE)0733-9445(2004)130:1(3 )10.1061/(ASCE)0733-9445(2004)130:1(3) ↗
10. Cashell KA (2009) Failure assessment of floor slab systems under extreme loading conditions, PhD Thesis, to be submitted, Imperial College London
11. Elghazouli AY, Izzuddin BA (2004) Failure of lightly reinforced concrete members under fire II: parametric studies and design considerations. J Struct Eng 130(1):18–31. doi: 10.1061/(ASCE)0733-9445(2004)130:1(18 )10.1061/(ASCE)0733-9445(2004)130:1(18) ↗
12. Morley PD, Royles R (1983) Response of the bond in reinforced concrete to high temperatures. Mag Concr Res 35(123):67–7410.1680/macr.1983.35.123.67 ↗
13. Sager H, Rostasy FS (1982) The effect of elevated temperature on the bond behavior of embedded reinforcing bars. In: Bartos P (ed) Bond in concrete. Applied Science Publishers, London, pp 206–216
14. Buchanan AH (2001) Structural design for fire safety. Wiley, New York
15. Anderberg Y (1978), Analytical fire engineering design of reinforced concrete structures based on real fire characteristics. Proceedings of the FIP, London, Part 1, pp 112–121
16. Eurocode 4 (2005). Design of composite steel and concrete structures: part 1.2: general rules-Structural fire design. European committe for standardization, Brussels. BS EN 1994-1-2
17. Twilt L (1988) Strength and deformation properties of steel at elevated temperatures: some practical implications. Fire Saf J 13:9–15. doi: 10.1016/0379-7112(88)90028-810.1016/0379-7112(88)90028-8 ↗