Impact of Fuel Type on Fire Dynamics in Mechanically Ventilated Compartment as a Consequence of Closing Inlet Vent
Source abstract
Abstract
In the industrial environments, one of the ways to prevent the spread of harmful fire by-products to adjacent compartments via ventilation networks consists in applying an Inlet Valve Closure procedure. A theoretical research by means of the experiments and the physics-based models is performed to investigate the consequences of closing air intake on fire behavior in the mechanically ventilated compartment. In well-ventilated conditions, the strategy of closing inlet vent can be considered as a positive factor with a reduction in HRR regardless of fuel type such as heptane or dodecane. In under-ventilated conditions, replacing heptane by dodecane with a higher boiling point leads to a change in fire dynamics regime from a ventilation to fuel controlled fire. Closing inlet vent contributes to a faster heptane fire growth with an increase in theoretical HRR by a factor of 5%, and however, exhaust of the ventilation controlled fire occurs more easily due to a reduction in combustion efficiency by a factor of 30%. However, for the dodecane fire, closing inlet vent facilitates a reduction in HRR over a longer burning period. Air entering the compartment follows closely the fluctuations of the fire induced pressure as a result of strong coupling process between drop in pressure and inlet flow rate. For the heptane fire in vitiated air environment, the impact of stopping inlet vent on the peak of unburnt species concentration seems negligible. Dodecane with a longer carbon chain produces more unburnt gases than heptane, and turning off air intake results in a reduction in unburnt species. Occurrence of flame extinction in the vitiated air enclosure makes a sudden supply of fresh air from dilution duct with an oxygen concentration of about 15%, ideal condition for triggering an eventual auto-ignition of a fuel–air mixture. With regarding the delay time for an ignition risk of unburnt pyrolyzates, the heptane fire appears more dangerous by closing inlet vent. For the dodecane fire, stopping inlet vent contributes to a prolongation in ignition delay time of unburnt pyrolyzates.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire dynamics and safety research · Combustion and Detonation Processes · Combustion and flame dynamics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. Audouin L, Rigollet L, Prétrel H, Le Saux W, Rowekamp M (2013) OECD Prisme project : Fires in confined and ventilated nuclear-type multi-compartments –Overview and main experimental results. Fire Saf J 62B:80–10110.1016/j.firesaf.2013.07.008 ↗
2. Prétrel H, Querre P, Foreestier M (2005) Experimental study of burning rate behavior in confined and ventilated fire compartments, Fire. Saf Sci 8:1217–1228
3. Vilfayeau S, Ren N, Wang Y, Trouvé A (2015) Numerical simulation of under-ventilated liquid-fueled compartment fires with flame extinction and thermally-driven fuel evaporation. Proc Combust Inst 35:2563–257110.1016/j.proci.2014.05.072 ↗
4. Lattimer BY, Ewens DT, Vansburger U, Roby RJ (1994) Transport and oxidation of compartment fire exhaust gases in an adjacent corridor. J Fire Protect Eng 6:163–18110.1177/104239159400600403 ↗
5. Loo ASX, Coppalle A, Yon J, Aîné P (2016) Time-dependent smoke yield and mass loss of pool fires in a reduced-scale mechanically ventilated compartment. Fire Saf J 81:32–4310.1016/j.firesaf.2016.01.006 ↗
6. Beyler CL (1986) Major species production by diffusion flames in a two-layer compartment fire environment. Fire Saf J 10:47–5610.1016/0379-7112(86)90031-7 ↗
7. Takeda N (1985) Oscillatory phenomenon and inverse temperature profile appearing in compartment fires. Combust Flame 61:103–10510.1016/0010-2180(85)90076-8 ↗
8. Lassus J, Studer E, Garo JP, Vantelon JP, Jourda P, Aine P (2010) Influence of ventilation on ignition risk of unburnt gases in the extraction duct of under ventilated compartment fire. Combust Sci Technol 182:517–52810.1080/00102200903463167 ↗
9. Prétrel H, Such JM (2005) Effect of ventilation procedures on the behavior of a fire compartment scenarios. Nucl Eng Des 235:2155–216910.1016/j.nucengdes.2005.03.003 ↗
10. Hostikka S, Kallada R, Riaz U, Sikanen T (2017) Fire-induced pressure and smoke spreading in mechanically ventilated buildings with air-tight envelopes. Fire Saf J 91:380–38810.1016/j.firesaf.2017.04.006 ↗
11. McgrattanK, Mcdermott R, Hostikka S, Floyd J (2018) Fire dynamics simulator (Version 6), User’s guide. NIST Special Publication
12. Zukoski EE (1984) Fluid dynamics aspects of room fires. In: First international symposium on fire safety science 1–3010.3801/IAFSS.FSS.1-1 ↗
13. Manescau B, Courty L, Acherar L, Coudour B, Wang HY, Garo JP (2020) Ventilation conditions effects during a fire in a reduced scale room. Process Saf Environ Prot 144:263–27210.1016/j.psep.2020.07.035 ↗
14. Brohez S, Delvosalle C, Marlair G (2004) A two-thermocouple probe for radiation corrections of measured temperatures in compartment fires. Fire Saf J 39(5):399–41110.1016/j.firesaf.2004.03.002 ↗
15. Murty KanuryA (1984) Introduction to combustion phenomena, New York: Gordon. ISBN 0-677-02690-0.
16. Stroup D, A Lindeman (2013) Verification and validation of selected fire models for nuclear power plant applications. NUREG-1824, supplement 1, United States Nuclear Regulatory Commission, Washington, DC, 37–48
17. Sikanen T, Hostikka S (2017) Predicting the heat release rates of liquid pool fires in mechanically ventilated compartments. Fire Saf J 91:266–27510.1016/j.firesaf.2017.03.060 ↗
18. Acherar L, Wang HY, Garo JP, Coudour B (2020) Impact of air intake position on fire dynamics in mechanically ventilated compartment. Fire Saf J 118:10321010.1016/j.firesaf.2020.103210 ↗
19. Ross HD, Miller FJ (1998) Flame spread across liquid pools with very low speed opposed or concurrent air flow. In: Twenty-Sixth Symposium (International) on Combustion, The Combustion Institute, Pittsburgh. 27:2 2723-272910.1016/S0082-0784(98)80128-8 ↗
20. Babrauskas V (1983) Estimating large pool fire burning rates. Fire Technol 19:251–26110.1007/BF02380810 ↗
21. Manescau B, Wang HY, Coudour B, Garo JP (2019) Influence of heat tightness of an enclosure fire on ignition risk of unburnt gases in a connected exhaust system: an experimental study. Fire Saf J 109:10286710.1016/j.firesaf.2019.102867 ↗
22. BrynerNP, Johnsson EL, Pitts WM (1994) Carbon monoxide production in compartment fires: reduced-scale enclosure test facility. National Institute of Standards and Technology. NISTIR-5568
23. SFPE Handbook of fire protection engineering (2016) National Fire Protection Association, Mohammed M. Khan, Archibald Tewarson and Marcos Chaos. In: Chapter 36, combustion characteristics of materials and generation of fire products , Fifth Edition, 1143–123210.1007/978-1-4939-2565-0_36 ↗
24. Moss JB, Stewart CD, Young KJ (1995) Modelling soot formation and burnout in a high temperature laminar diffusion flame burning under oxygen-enriched conditions. Combust Flame 101:491–50010.1016/0010-2180(94)00233-I ↗
25. Janssens Marc L (1991) Measuring rate of heat release by oxygen consumption. Fire Technol 27:234–24910.1007/BF01038449 ↗
26. Pretrel H, Le Saux W, Audouin L (2012) Pressure variations induced by a pool fire in a well confined and force-ventilated compartment. Fire Saf J 52:11–2410.1016/j.firesaf.2012.04.005 ↗
27. Burgess MJ, Wheeler RV, The lower limit of inflammation of mixtures of paraffin hydrocarbons with air. J Chem Soc Trans XCIX (1911), 2013–203010.1039/CT9119902013 ↗
28. Ignition Handbook, Fire Science Publishers, Babrauskas, V., Chapter 4, (2003), 41–140
29. ZabetakisMG (1965) Flammability characteristics of combustible gases and vapours, US Dept of the Interior, Bureau of Mines, (1965), bulletin 62710.2172/7328370 ↗
30. Melguizo G, Shepherd JE (2015) Hot surface ignition and flow separation. In: 25th ICDERS, Aug. 2–7, 2015, Leeds, UK