Synchronous Displacement Acquisition Approach for Early Warning of Fire-induced Collapse of Steel Portal Frames
Source abstract
Abstract
Unexpected collapse accidents of burning buildings have greatly threatened firefighters and trapped people. Hence, accurate real-time early warning of fire-induced collapse of burning buildings is urgently needed to avoid unnecessary casualties. Existing research evaluated the collapse state of the burning building and issued an early warning before the collapse by analyzing the variation laws of displacements at key positions. However, some displacements are hard to acquire rapidly and accurately at fire rescue scenes, which restricts the application of early-warning methods in real fires. This paper proposes a synchronous real-time displacement acquisition approach for early warning of fire-induced collapse of steel portal frames. The three-order polynomial function is adopted to represent the deformation curve of members in frames under fire conditions. The displacements measured by on-site arranged microwave radars coupled with rotations measured by embedded inclinometers are adopted for determining the polynomial function and synchronously predicting displacements of the burning frame at any location. The research findings show that placing five inclinometers on each roof and three inclinometers on each internal column with equal spacing can accurately predict displacements of the overall frame. Slope-based weights and reset conditions with thresholds are proposed to consider the effects of heating conditions and structural parameters in order to improve the accuracy and reliability of the acquisition approach. Parametric analyses and case studies are presented to illustrate the application and robustness of the proposed approach in early warning of fire-induced collapse of steel portal frames.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Response to Dynamic Loads · Fire dynamics and safety research · Fire effects on concrete materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (42)
Show source-provided references
1. Deng E, Zong L, Ding Y, Zhang Z, Zhang J, Shi F, Cai L, Gao S (2020) Seismic performance of mid-to-high rise modular steel construction—a critical review. Thin-Walled Struct 155:106924. https://doi.org/10.1016/j.tws.2020.10692410.1016/j.tws.2020.106924 ↗
2. Zeng X, Wu W, Huo J, Elchalakani M (2021) Residual mechanical properties of Q890 high-strength structural steel after exposure to fire. Constr Build Mater 304(18):124661. https://doi.org/10.1016/j.conbuildmat.2021.12466110.1016/j.conbuildmat.2021.124661 ↗
3. NFPA 101A (2011) Guide on alternative approaches to life safety. National Fire Protection Association, Quincy
4. GB60016–2014 (2014) Code for fire protection design of buildings. China Planning Press, Beijing ((in Chinese))
5. Bu F, Gharajeh MS (2019) Intelligent and vision-based fire detection systems: a survey. Image Vis Comput 91:103803. https://doi.org/10.1016/j.imavis.2019.08.00710.1016/j.imavis.2019.08.007 ↗
6. Huang L, Liu G, Wang Y, Yuan H, Chen T (2022) Fire detection in video surveillances using convolutional neural networks and wavelet transform. Eng Appl Artif Intell 110:104737. https://doi.org/10.1016/j.engappai.2022.10473710.1016/j.engappai.2022.104737 ↗
7. Zhang Q, Wang YC, Soutis C, Gresil M (2021) Development of a fire detection and suppression system for a smart air cargo container. The Aeronaut J 125(1283):205–222. https://doi.org/10.1017/aer.2020.8910.1017/aer.2020.89 ↗
8. Zhou G, Li S, Zhang X, Liu Z, He M, Chen X, Yang W (2022) Synthesis and properties of a fire-retardant coating based on intercalated expandable graphite-modified cellulose for steel structures. J Build Eng 51:104270. https://doi.org/10.1016/j.jobe.2022.10427010.1016/j.jobe.2022.104270 ↗
9. Davesne A, Jimenez M, Samyn F, Bourbigot S (2021) Thin coatings for fire protection: an overview of the existing strategies, with an emphasis on layer-by-layer surface treatments and promising new solutions. Prog Organ Coat 154:106217. https://doi.org/10.1016/j.porgcoat.2021.10621710.1016/j.porgcoat.2021.106217 ↗
10. Xu Q, Li GQ, Wang YC (2021) A simplified method for calculating non-uniform temperature distributions in thin-walled steel members protected by intumescent coating under localized fires. Thin-Wall Struct 162:107580. https://doi.org/10.1016/j.tws.2021.10758010.1016/j.tws.2021.107580 ↗
11. Fang C, Izzuddin BA, Obiala R, Elghazouli AY, Nethercot DA (2012) Robustness of multi-storey car parks under vehicle fire. J Constr Steel Res 75:72–84. https://doi.org/10.1016/j.jcsr.2012.03.00410.1016/j.jcsr.2012.03.004 ↗
12. Usmani A, Chung YC, Torero JL (2003) How did the WTC towers collapse: a new theory. Fire Saf J 38:501–503. https://doi.org/10.1016/S0379-7112(03)00069-910.1016/S0379-7112(03)00069-9 ↗
13. Chen S, Jiang L, Wu L, Wang Y, Usmani A (2019) Damage investigation of cementitious fire resistive coatings under complex loading. Constr Build Mater 204(20):659–674. https://doi.org/10.1016/j.conbuildmat.2018.12.21710.1016/j.conbuildmat.2018.12.217 ↗
14. MacLeod J, Tan S, Moinuddin K (2020) Reliability of fire (point) detection system in office buildings in Australia—a fault tree analysis. Fire Saf J 115:103150. https://doi.org/10.1016/j.firesaf.2020.10315010.1016/j.firesaf.2020.103150 ↗
15. Kang R, Fu G, Yan J (2016) Analysis of the case of fire fighters casualties in the building collapse. Procedia Eng 13:343–348. https://doi.org/10.1016/j.proeng.2016.01.14010.1016/j.proeng.2016.01.140 ↗
16. Jiang L, Zhang Q, Shi J, Li Y (2012) Statistic study on sacrifices of firefighters in China. Procedia Eng 45:700–704. https://doi.org/10.1016/j.proeng.2012.08.22610.1016/j.proeng.2012.08.226 ↗
17. Lou G, Wang C, Jiang J, Jiang Y, Wang L, Li GQ (2018) Fire tests on full-scale steel portal frames against progressive collapse. J Constr Steel Res 145:137–152. https://doi.org/10.1016/j.jcsr.2018.02.02410.1016/j.jcsr.2018.02.024 ↗
18. Roy K, Lim JBP, Lau HH, Yong PM, Clifton GC, Johnston RPD, Wrzesien A, Mei CC (2019) Collapse behaviour of a fire engineering designed single-storey cold-formed steel building in severe fires. Thin-Wall Struct 142:340–357. https://doi.org/10.1016/j.tws.2019.04.04610.1016/j.tws.2019.04.046 ↗
19. Wong SY (2001) The structural response of industrial portal frame structures in fire. University of Sheffield, Sheffield
20. Lou G, Wang C, Jiang J, Jiang Y, Wang L, Li GQ (2018) Experimental and numerical study on thermal-structural behavior of steel portal frames in real fires. Fire Saf J 98:48–62. https://doi.org/10.1016/j.firesaf.2018.04.00610.1016/j.firesaf.2018.04.006 ↗
21. Pyl L, Schueremans L, Dierckx W, Georgieva I (2012) Fire safety analysis of a 3D frame structure based on a full-scale fire test. Thin-wall Struct 61:204–212. https://doi.org/10.1016/j.tws.2012.03.02310.1016/j.tws.2012.03.023 ↗
22. Ali HM, Senseny PE, Alpert RL (2004) Lateral displacement and collapse of single-story steel frames in uncontrolled fires. Eng Struct 26:593–607. https://doi.org/10.1016/j.engstruct.2003.12.00710.1016/j.engstruct.2003.12.007 ↗
23. Moss PJ, Dhakal RP, Bong MW, Buchanan AH (2009) Design of steel portal frame buildings for fire safety. J Constr Steel Res 65:1216–1224. https://doi.org/10.1016/j.jcsr.2008.09.00310.1016/j.jcsr.2008.09.003 ↗
24. Li GQ, Ji W, Feng C, Wang Y, Lou G (2021) Experimental and numerical study on collapse modes of single span steel portal frames under fire. Eng Struct 245:112968. https://doi.org/10.1016/j.engstruct.2021.11296810.1016/j.engstruct.2021.112968 ↗
25. EI-Heiweity MM (2012) Behavior of portal frames of steel hollow sections exposed to fire. Alexandria Eng J 51:95–107. https://doi.org/10.1016/j.aej.2012.06.00410.1016/j.aej.2012.06.004 ↗
26. Akaa OU, Abu A, Spearpoint M (2020) A case study of design decision-making for an exemplar steel portal-framed building under fire exposure using a hybrid analysis technique. J Build Eng 28:101093. https://doi.org/10.1016/j.jobe.2019.10109310.1016/j.jobe.2019.101093 ↗
27. Jiang J, Wang C, Lou G, Li GQ (2018) Quantitative evaluation of progressive collapse process of steel portal frames in fire. J Constr Steel Res 150:277–287. https://doi.org/10.1016/j.jcsr.2018.08.02010.1016/j.jcsr.2018.08.020 ↗
28. Ji W, Li GQ, Lou G (2022) Early-warning methods for fire-induced collapse of single-span steel portal frames. J Constr Steel Res 190(2):107154. https://doi.org/10.1016/j.jcsr.2022.10715410.1016/j.jcsr.2022.107154 ↗
29. Ji W, Zhu S, Li GQ, Lou G, Jiang S (2022) Approach for early-warning collapse of double-span steel portal frames induced by fire. Fire Saf J 131:103628. https://doi.org/10.1016/j.firesaf.2022.10362810.1016/j.firesaf.2022.103628 ↗
30. Li G, Ji W, Feng C, Wang Y, Li X, Liang T, Shi X, Liu X (2021) Collapse test of steel portal frame under fire and effective analysis of radar-based displacement measuring system. Chin Civil Eng J 54(09):56–65 ((in Chinese))
31. Hou S, Zeng C, Zhang H, Ou J (2018) Monitoring interstory drift in buildings under seismic loading using MEMS inclinometers. Constr Build Mater 185:453–467. https://doi.org/10.1016/j.conbuildmat.2018.07.08710.1016/j.conbuildmat.2018.07.087 ↗
32. Cheung A, Kiremidjian AS (2014) Development of a rotation algorithm for earthquake damage diagnosis. Earthq Spectra 30(4):1381–1401. https://doi.org/10.1193/012212EQS016M10.1193/012212EQS016M ↗
33. 02SG518–1 (2002) Design of light steel portal frames. China Building Standard Design and Research Institute, Beijing ((in Chinese))
34. 07SG518–4 (2007) Design of light steel portal frames. China Building Standard Design and Research Institute, Beijing ((in Chinese))
35. Eurocode 3 (2005) Design of steel structures-part 1–1: general rules and rules for buildings. European Committee for Standardization, Brussels
36. Rahman M, Xu Y (2013) Behavior of steel portal frames in fire: comparison of implicit and explicit dynamic finite element methods. Int J Struct Stab Dyn 13(4):1250058. https://doi.org/10.1142/S021945541250058710.1142/S0219455412500587 ↗
37. ISO 834–1 (1999) Fire-resistance tests-elements of building construction part 1: general requirements. International Organization for Standardization (ISO), Geneva
38. GB51249–2017 (2017) Code for fire safety of steel structures in buildings. China Planning Press, Beijing ((in Chinese))
39. Marshall HS (1948) The generalized Weierstrass approximation theorem. Math Mag 21(5):237–254. https://doi.org/10.2307/302933710.2307/3029337 ↗
40. Kirby BR (1997) Large scale fire tests: The British Steel European Collaborative Research Programme on the BRE 8-storey Frame. Fire Saf Sci 5:1129–1140. https://doi.org/10.3801/IAFSS.FSS.5-112910.3801/IAFSS.FSS.5-1129 ↗
41. Roberts MJ, Davies JM, Wang YC (2021) Numerical analysis of a clad portal frame structure tested to destruction. Structures 33:3779–3797. https://doi.org/10.1016/j.istruc.2021.06.09810.1016/j.istruc.2021.06.098 ↗
42. Gryniewicz M, Roberts MJ, Davies JM (2021) Testing and analysis of a full-scale steel-framed building including the consideration of structure-cladding interaction. J Construct Steel Res 181:106611. https://doi.org/10.1016/j.jcsr.2021.10661110.1016/j.jcsr.2021.106611 ↗