Investigation of Sprinkler Sprays on Fire Induced Doorway Flows
Source abstract
Abstract
Performance based methodologies are becoming increasingly common in fire safety due to the inability of prescriptive codes to account for every architectural feature. Fire Sprinkler suppression systems have long been used to provide property protection and enhance life safety. However, very few methodologies exist to account for the impact of sprinkler sprays on fire scenarios. Current methods are extremely complicated and difficult to use as an engineering tool for performance based design. Twenty-four full scale fire tests were conducted at Tyco Fire Suppression & Building Products Global Technology Center to determine a simple method for accounting for the impact of a single residential sprinkler on fire induced doorway flows. It was found that a spraying sprinkler reduced the mass flows at the doorway while maintaining two stratified layers away from the sprinkler spray. The mass flow reduction was consistent and could be predicted through the use of a simple buoyancy based equation. The current study suggests that the buoyancy equation can be altered through the use of a constant cooling coefficient (equal to 0.84 for a Tyco LFII (TY2234) sprinkler) based on the test results reported in this paper. This study is a proof of concept and the results suggest the methodology can be applicable to similar situations.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire dynamics and safety research · Evacuation and Crowd Dynamics · Wind and Air Flow Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (22)
Show source-provided references
1. Gann RG, Babrauskas V, Peacock RD, Hall JR (1994) Fire Conditions for Smoke Toxicity Measurement. Fire Mater 18:193–199. doi: 10.1002/fam.81018030610.1002/fam.810180306 ↗
2. Cooper LY (1995) The Interaction of an Isolated Sprinkler Spray and a Two-Layer Compartment Fire Environment. Int J Heat Mass Transfer 38(4):679–690. doi: 10.1016/0017-9310(94)00188-210.1016/0017-9310(94)00188-2 ↗
3. Bullen ML (1977) The Effect of a Sprinkler on the Stability of a Smoke Layer beneath a Ceiling. Fire Technol 13(1):21–34. doi: 10.1007/BF0233888310.1007/BF02338883 ↗
4. You HZ, Kung HC, Han Z (1989) The effects of spray cooling on the ceiling gas temperature at the door opening of room fires. In: Proceedings of the second international symposium on fire safety science, Hemisphere, NY, pp 655–66510.3801/IAFSS.FSS.2-655 ↗
5. Chow WK, Fong NK (1991) Numerical Simulation on Cooling the Fire-induced Air Flow by Sprinkler Water Sprays. Fire Saf J 17:263–290. doi: 10.1016/0379-7112(91)90023-R10.1016/0379-7112(91)90023-R ↗
6. Morgan HP (1979) Heat Transfer from a Buoyant Smoke Layer Beneath a Ceiling to a Sprinkler Spray 1. A. Tentative Theory. Fire Mater 3:27–32. doi: 10.1002/fam.81003010610.1002/fam.810030106 ↗
7. Morgan HP (1979) Heat Transfer from a Buoyant Smoke Layer Beneath a Ceiling to a Sprinkler Spray. 1. An Experiment. Fire Mater 3:34–38. doi: 10.1002/fam.81003010710.1002/fam.810030107 ↗
8. Alpert RL (1985) Numerical Modeling of the Interaction Between Automatic Sprinkler Sprays and Fire Plumes. Fire Saf J 9:157–163. doi: 10.1016/0379-7112(85)90003-710.1016/0379-7112(85)90003-7 ↗
9. Forney GP, McGrattan KB (1985) Computing the effects of sprinkler sprays on fire induced gas flow. In: Proceedings of the international conference on fire research and engineering, Society of Fire Protection Engineers, Orlando
10. Sheppard DT (2002) Spray characteristics of fire sprinklers. PhD Dissertation, Northwestern University, Evanston, IL
11. Emmons HW (2002) Vent flows, Sections 2–3, 3rd edn. SFPE handbook of fire protection engineering, National Fire Protection Association, Quincy, MA
12. Emmons HW (1975) Fire Induced Flow Through an Opening. Combust Flame 25:369–385. doi: 10.1016/0010-2180(75)90109-110.1016/0010-2180(75)90109-1 ↗
13. Rockett JA (1976) Fire Induced Gas Flow in an Enclosure. Combust Sci Technol 12:165–175. doi: 10.1080/0010220760894671710.1080/00102207608946717 ↗
14. Steckler KD, Quintiere JG, Rinkinen WJ (1982) “Flow Induced by Fire in a Compartment,” NBSIR 82-2520, National Bureau of Standards, Washington, D.C
15. Nakaya I, Tanaka T, Yoshida M (1986) Doorway Flow Induced by a Propane Fire. Fire Saf J 10:185–195. doi: 10.1016/0379-7112(86)90015-910.1016/0379-7112(86)90015-9 ↗
16. Dembsey NA, Pagni PJ, Williamson RB (1995) Compartment Near-field Entrainment Measurements. Fire Saf J 24:383–419. doi: 10.1016/0379-7112(95)00030-510.1016/0379-7112(95)00030-5 ↗
17. Karlsson B, Quintiere JG (2000) “Enclosure Fire Dynamics,” CRC Press, Boca Raton, FL
18. McCaffrey BJ, Heskasted G (1976) A Robust Bidirectional Low-Velocity Probe for Flame and Fire Application. Combust Flame 26(1):125–127. doi: 10.1016/0010-2180(76)90062-610.1016/0010-2180(76)90062-6 ↗
19. Taylor JR (1997) “An Introduction to Error Analysis: The Study of Uncertainties in Physical Measurements,” University Science Books
20. Zhao L (2008) Dembsey, N.A. “Measurement uncertainty analysis for calorimetry apparatuses. Fire Mater 32(1):1–26. doi: 10.1002/fam.94710.1002/fam.947 ↗
21. Crocker JP (2008) “The Effect of Sprinkler Sprays on Fire Induced Doorway Flows,” Worcester Polytechnic Institute, Department of Fire Protection Engineering, Worcester, MA
22. Janssens M, Tran HC (1992) Data Reduction of Room Tests for Zone Model Validation. J Fire Sci 10(6):528–555. doi: 10.1177/07349041920100060410.1177/073490419201000604 ↗