Experimental Study on Thermal Buoyancy Influence on the Spill Flame Plume in Dual-Openings Compartment Fires
Source abstract
Abstract
When there are multiple openings with different heights in fire rooms after flashover, the spill flame acquires relatively high initial momentum due to strong buoyancy force compared to that in a fire room with only a single opening. The high initial momentum can influence the shapes of spill flame plume to a large extent. However, the characteristic of spill flame plume projecting from a compartment with dual openings have not been fully studied so far. In present study, a total of 20 experiments were carried out in a 1/3 scale dual openings compartment with different opening geometries and heat release rates to investigate the thermal buoyancy force effect on the projecting flame from the window after flashover. Based on the theoretical analysis, two characteristic lengths were proposed to represent the buoyancy force after flashover in the compartment. Results show that the spill flame height and width were proportional to 1.65 and 0.48 power of the heat release rate of the spill fire plume, respectively. In addition, the relationship between the periodic oscillation (about 0.8 Hz) of spill flame and the geometry of the compartment opening was analyzed.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire dynamics and safety research · Evacuation and Crowd Dynamics · Fire Detection and Safety Systems
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. Chow WK, Zou GW (2005) Correlation equations on fire-induced air flow rates through doorway derived by large eddy simulation. Build Environ 40:897–90610.1016/j.buildenv.2004.09.010 ↗
2. Harish R, Venkatasubbaiah K (2013) Transport phenomena of turbulent fire spread through compartment connected to vertical shaft in tall building. Fire Saf J 61:160–17410.1016/j.firesaf.2013.09.005 ↗
3. Harish R, Venkatasubbaiah K (2015) Large eddy simulation of thermal plume behavior in horizontally partitioned dual enclosure, Build Simul 8(2):137–14810.1007/s12273-014-0198-z ↗
4. Li J, Chen C, Shen B (2014) Experimental study on gas temperature during fire in a compartment with a sloped roof vent. Fire Technol 50(6):1483–1498.10.1007/s10694-013-0344-7 ↗
5. Zhang J, Lu S, Li C, et al (2014) Fire-induced temperature correlations in ceiling vented compartments. Fire Technol 51(2):369–379.10.1007/s10694-014-0386-5 ↗
6. Goble K (2007) Height of flames projecting from compartment openings. Fire Engineering Research Thesis, Department of Civil Engineering, University of Canterbury, New Zealand
7. Yokoi S (1960) Study on the prevention of fire spread caused by hot upward current. Japan, Report 34, Report of the Building Research Institut.
8. Himoto K, Tsuchihashi T, Tanaka Y, Tanaka T (2009) Modeling the trajectory of window flames with regard to flow attachment to the adjacent wall. Fire Saf J 44:250–258.10.1016/j.firesaf.2008.06.007 ↗
9. Karlsson B, Quintiere JG (1999) Fire plumes and flame heights, chapter 4: enclosure fire dynamics, CRC Press LLC, Boca Raton10.1201/9781420050219 ↗
10. Delichatsios MA, Orloff L (1985) Entrainment measurements in turbulent buoyant jet flames and implications for modeling. Proc Combust Inst 20:367–375.10.1016/S0082-0784(85)80523-3 ↗
11. Delichatsios MA (1987) Air entrainment into buoyant jet flames and pool fires. Combust Flame 70:33–46.10.1016/0010-2180(87)90157-X ↗
12. Delichatsios MA (1993) Transition from momentum to buoyancy-controlled turbulent jet diffusion flames and flame height relationships. Combust Flame 92:349–364.10.1016/0010-2180(93)90148-V ↗
13. Lee YP, Delichatsios MA, Silcock GWH (2007) Heat fluxes and flame heights in facades from fires in enclosures of varying geometry. Proc Combust Inst 31(2):2521–252810.1016/j.proci.2006.08.033 ↗
14. Stavrakakis GM, Markatos NC (2009) Simulation of airflow in one- and two-room enclosures containing a fire source. Int J Heat Mass Transf 52:2690–270310.1016/j.ijheatmasstransfer.2007.10.046 ↗
15. Kumar R, Naveen M (2007) An experimental fire in compartment with dual vent on opposite walls. Combust Sci Technol 179(8):1527–154710.1080/00102200701202650 ↗
16. Kumar R, Naveen M (2007) Compartment fires: CALTREE and cross-ventilation. Combust Sci Technol 179(8):1549–1567.10.1080/00102200701202676 ↗
17. Lu KH (2015) Studies on façade flame entrainment and flame height from a compartment under various opening and side wall constraint boundary conditions. PhD Thesis, University of Science and Technology of China, Hefei
18. Chen HX, Liu NA, Chow WK (2011) Wind tunnel tests on compartment fires with crossflow ventilation. J Wind Eng Ind Aerodyn 99:1025–103510.1016/j.jweia.2011.07.006 ↗
19. Huang H, Ooka R, Liu N, Zhang L, Deng Z, Kato S (2009) Experimental study of fire growth in a reduced-scale compartment under different approaching external wind conditions. Fire Saf J 44(3):311–321.10.1016/j.firesaf.2008.07.005 ↗
20. Thomas PH, Hinkley PL, Theobald CR, Simms DL (1963) Investigations into the flow of hot gases in roof venting, Fire Research Technical Paper No. 7. The Stationary Office, London
21. Morgan HP, Marshall N, Goldstone B (1976) Smoke hazards in covered, multi-level shopping malls: some studies using a model 2-storey mall. Build Res Establ 86:1–3
22. Otsu N (1979) A threshold selection method from gray-level histogram. IEEE Trans Syst Man Cybern 9:62–66.10.1109/TSMC.1979.4310076 ↗
23. Tamura GT (1994) Smoke movement and control in high rise buildings. National Fire Protection Association, Quincy
24. Zukoski EE, Cetegen BM, Kubota T (1984) Visible structures of buoyant diffusion flames. Proc Combust Inst 20:361–366
25. Yokoi S (1960) Study on the prevention of fire spread caused by hot upward current. Japan, Report 34, Report of the Building Research Institute.
26. Tang F, Hu LH, Delichatsios MA, Lu KH, Zhu W (2012) Experimental study on flame height and temperature profile of buoyant window spill flame plume from an under-ventilated compartment fire. Int J Heat Mass Transf 55:93–10110.1016/j.ijheatmasstransfer.2011.08.045 ↗
27. Zukoski EE (1995) Properties of fire flame plumes, combustion fundamentals of fire. Academic Press, London
28. Tu R, Fang J, Zhang YM, Zhang J, Zeng Y (2013) Effects of low air pressure on radiation-controlled rectangular ethanol and n-heptane pool fires. Proc Combust Inst 34(2): 2591–259810.1016/j.proci.2012.06.036 ↗
29. Fang J, Tu R, Guan JF, Wang JJ, Zhang YM (2011) Influence of low air pressure on combustion characteristics and flame pulsation frequency of pool fires. Fuel 90(8):2760–276610.1016/j.fuel.2011.03.035 ↗
30. Cetegen BM, Ahmed TA (1993) Experiments on the periodic instability of buoyant flame plumes and pool fires. J Combust Flame 93:157–18410.1016/0010-2180(93)90090-P ↗