Fire Resistance of Wood Truss Floor Assemblies
Source abstract
Abstract
This paper presents and discusses the factors that affect the fire resistance performance of lightweight wood truss floor assemblies protected with two layers of Type X gypsum board ceiling finishes. Fifteen full-scale fire resistance floor experiments were conducted using the CAN/ULC S-101 fire resistance standard which is similar to the ASTM E119. Parameters investigated in this study include the effects of insulation installation in floor cavity, insulation type, wood truss spacing, resilient channel installation, resilient channel spacing, wood truss width, wood truss chord orientation, wood truss web type, wood truss connection type and adding concrete topping above the sub-floor. The impact of these parameters on the fire resistance performance of the wood truss floor assemblies is discussed. The fire resistance of wood truss floors appears to be essentially governed by the wood trusses’ spacing for direct application of gypsum board to wood truss framing, insulation type and resilient channel installation and spacing. Other parameters are of secondary importance.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire effects on concrete materials · Wood Treatment and Properties · Structural Load-Bearing Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (19)
Show source-provided references
1. National Building Code of Canada 1990 Edition (Part 9), National Research Council Canada, Ottawa, ON
2. National Building Code of Canada 1995 Edition (Part 9), National Research Council Canada, Ottawa, ON
3. Sultan MA, Seguin YP, Leroux (1998) Results of fire resistance tests on full-scale floor assemblies, Internal report No. 764. Institute for Research in Construction, National Research Council of Canada, Ottawa
4. Sultan M, Latour JC, Leroux P, Monette RC, Seguin YP, Henrie J (2005) Results of fire resistance tests on full-scale floor assemblies: phase II, Research report 184, Institute for research in construction 2005 edition. National Research Council Canada, Ottawa
5. CAN/ULC-S101 (1989) Standard methods of fire endurance tests of building construction and materials. Underwriters’ Laboratories of Canada, Scarborough
6. ASTM E119 (1988) Standard test method for fire tests of building construction and materials. ASTM, West Conshohocken
7. Sultan MA (2008) Fire resistance of wood joists floor assembles. Fire Technol 44(4):383–41710.1007/s10694-007-0038-0 ↗
8. Sultan MA (2009) Fire resistance of steel C-joists floor assembles. Fire Technol 46(2):375–40510.1007/s10694-009-0083-y ↗
9. National Building Code of Canada 2005 Edition (Part 9). National Research Council Canada, Ottawa
10. National Building Code of Canada 2010 Edition. National Research Council of Canada, Ottawa
11. White RH, Cramer SM, Shresdtha DK (1993) Fire endurance model for a metal-plate-connect wood truss, Res. Pab., FRL-RP-522. US Department of Agriculture, Forest Service, Forest Products Laboratory, Madison
12. Shestha DK (1992) Fire endurance modeling of metal-plate connected wood truss. PhD Dissertation, University of Wisconsin, Madison
13. CAN/CSA-A82.31-M91 (1991) Gypsum board application. Canadian Standards Association, Rexdale
14. CSA A101-M83 (1983) Thermal insulation. Canadian Standards Association, Rexdale
15. CAN/ULC-S702-M97 (1997) Standard for mineral fibre thermal insulation for buildings. Underwriters’ Laboratories of Canada, Scarborough
16. CAN/CGSB 51.60-M90 (1990) Cellulose fibre loose fill thermal insulation. Canadian Standards Board, Ottawa
17. CAN/CSA-82.27-M91 (1991) Gypsum board. Canadian Standards Association, Etobicoke
18. ASTM C36-97 (1997) Standard specification for gypsum wallboard. American Society for Testing and Materials, West Conshohocken
19. Shorter GW, Harmathy TZ (1960) Fire Research Furnaces at the National Research Council, NRC 5732, National Research Council of Canada, Ottawa