Multi-degree-of-freedom Hybrid Fire Testing of a Column in a Non-linear Environment
Source abstract
Abstract
Hybrid fire testing is a testing method for structures on fire based on a substructuring method. A complete structure is divided in two substructures, one in a fire test laboratory (physical substructure), and one numerically simulated (numerical substructure). In fire engineering, some hybrid fire tests have been successfully performed in the last decades, but as the method is still in its infancy, these hybrid tests were limited to one-degree-of-freedom tests. The paper presents the first successful multi-degree-of-freedom hybrid test performed in fire engineering. The physical substructure is a steel column with an axial displacement and rotations at the ends controlled by electric jacks. The numerical substructure is a non-linear 2D plane frame structure modelled in SAFIR. The equations of the algorithm, the experimental setup, the testing process, and the results are presented.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire effects on concrete materials · Structural Response to Dynamic Loads · Engineering and Material Science Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (22)
Show source-provided references
1. Hakuno M, Shidawara M, Hara T (1969) Dynamic destructive test of a cantilever beam controlled by an analog-computer. Proceedings of the Japan society of civil engineers, Japan society of civil engineers, pp 1–910.2208/jscej1969.1969.171_1 ↗
2. Korzen M, Magonette G, Buchet P (1998) Mechanical loading of columns in fire tests by means of the substructuring method. In: Proceedings of the Eighth interflam conference, Edinburgh (United Kingdom), pp 911–914
3. Robert F, Rimlinger S, Collignon C (2010) Structure fire resistance: a joint approach between modelling and full scale testing (substructuring system). 3rd fib International Congress
4. Mostafaei H (2013) Hybrid fire testing for assessing performance of structures in fire—application. Fire Saf J 56:30–3810.1016/j.firesaf.2012.12.003 ↗
5. Franssen J-M, Gernay T (2017) Modeling structures in fire with SAFIR: theoretical background and capabilities. J Struct Fire Eng 8:300–32310.1108/JSFE-07-2016-0010 ↗
6. Pinoteau N, Pham DT, Nguyen HH, Mège R (2020) Development of hybrid fire testing by real-time subdivision of physical and numerical substructures. J Struct Fire Eng 11(4):481–497. https://doi.org/10.1108/JSFE-07-2019-002610.1108/JSFE-07-2019-0026 ↗
7. Sauca A, Gernay T, Robert F, Tondini N, Franssen J-M (2018) Hybrid fire testing: discussion on stability and implementation of a new method in a virtual environment. J Struct Fire Eng. https://doi.org/10.1108/JSFE-01-2017-001710.1108/JSFE-01-2017-0017 ↗
8. Whyte CA, Mackie KR, Stojadinovic B (2016) Hybrid simulation of thermomechanical structural response. J Struct Eng 142:04015107-1-04015107–1110.1061/(ASCE)ST.1943-541X.0001346 ↗
9. Schulthess P, Neuenschwander M, Mosalam KM, Knobloch M (2020) A computationally rigorous approach to hybrid fire testing. Comput Struct 238:10630110.1016/j.compstruc.2020.106301 ↗
10. Grolimund R (2019) Consolidated fire analysis - towards coupled numerical-experimental analysis of fire-exposed structures with stability problems. École polytechnique fédérale de Zurich, Dissertation
11. Wang X, Kim RE, Kwon O-S, Yeo I (2018) Hybrid simulation method for a structure subjected to fire and its application to a steel frame. J Struct Eng 144(8):0401811810.1061/(ASCE)ST.1943-541X.0002113 ↗
12. Menari M, Wang X, Mahmoud H, Kwon O (2020) Response of a structure subjected to fire following an earthquake event. ASCE J Struct Eng 146(1):0401918210.1061/(ASCE)ST.1943-541X.0002466 ↗
13. Abbiati G, Covi P, Tondini N, Bursi OS, Stojadinović B (2020) A real-time hybrid fire simulation method based on dynamic relaxation and partitioned time integration. J Eng Mech 146(9):0402010410.1061/(ASCE)EM.1943-7889.0001826 ↗
14. Sauca A, Mortensen N, Drustrup A, Abbiati G (2021) Experimental validation of a hybrid fire testing framework based on dynamic relaxation. Fire Saf J 121:103315. https://doi.org/10.1016/j.firesaf.2021.10331510.1016/j.firesaf.2021.103315 ↗
15. Tsokanas N, Abbiati G, Kanellopoulos K, Stojadinović B (2021) Multi-axial hybrid fire testing based on dynamic relaxation. Fire Saf J 126:103468. https://doi.org/10.1016/j.firesaf.2021.10346810.1016/j.firesaf.2021.103468 ↗
16. Quershi RK (2021) Evaluation of steel columns under fire: real-time hybrid testing and reliability assessment. State University of New York at Buffalo, Dissertation
17. Mergny E, Drion G, Franssen J-M (2020) Stability in hybrid fire testing using PI control. Exp Tech 44(6):687–69910.1007/s40799-020-00375-8 ↗
18. Sauca A (2017) Development and implementation of a methodology for hybrid fire testing applied to concrete structures with elastic boundary conditions (Dissertation). Liege University
19. Shing PB, Mahin SA (1983) Experimental error propagation in pseudodynamictesting. Report UCB/EERC-83/12, Berkeley: Earthquake Engineering Research Center, University of California
20. Urthale Y, Reddy JN (2005) Communications in numerical methods in engineering. pp 553–57010.1002/cnm.773 ↗
21. Mergny E (2021) Multi-degree-of-freedom hybrid fire testing in a non-linear environment. Liege University, Dissertation10.1007/s10694-022-01258-7 ↗
22. BIPM, IEC, IFCC, ILAC, ISO, IUPAC, IUPAP and OIML (2008) Guide to the expression of uncertainty in measurement. JCGM 100 (GUM 1995 with minor corrections)