Overview of Factors Affecting the Behavior of Reinforced Concrete Columns with Imperfections at High Temperature
Source abstract
Abstract
In this paper, the behavior of initially imperfect reinforced concrete columns with different eccentricity and end restraint conditions at elevated temperatures is studied. By constructing column curves for the heated columns, the combined and interrelated effects of initial imperfection patterns, rotational end restraint level, self-equilibrating thermal stresses, and end eccentricity condition for columns with different slenderness ratios are investigated. The study shows that for each column curve, there exists a characteristic fire resistance that is a maximum and not affected by end restraint characteristic. It was found that for all columns, there is a critical value of slenderness ratio after which column responses to fire change. It was also found that under certain conditions, an antisymmetrically loaded column with an initial out-of-straightness experiences a double-phase unwinding phenomenon and may fail in a single-curvature buckling mode, but they cannot buckle in an antisymmetrical double-curvature mode. This is quite different from symmetrically loaded columns with initial out-of-straightness of opposite sense of gravest buckling mode, which show a single-unwinding phenomenon and can fail in either a single- or a double-curvature buckling mode. The investigation revealed that the values of effective length factor at high temperatures are different from those at ambient temperature, and these values are slightly affected by the end eccentricity, column slenderness, and load ratio.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire effects on concrete materials · Fire dynamics and safety research · Structural Load-Bearing Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. Lie TT, Woollerton JL (1988) Fire safety of reinforced concrete columns. NRCC, Canada, Internal Report No 569.
2. Aldea CM, Franssen JM, Dotreppe JC (1997) Fire test on normal and high strength reinforced concrete columns. Gaithersburg, Maryland, USA, National Institute of Science and Technology.
3. Dotreppe JC, Franssen JM, Bruls A, Baus R, Vandevelde P, Minne R, van Nieuwenburg D, Lambotte H (1997) Experimental research on the determination of the main parameters affecting the behavior of reinforced concrete columns under fire conditions. Mag Concr Res 49(179):117–12710.1680/macr.1997.49.179.117 ↗
4. Ali FD, O’Connor D, Abu-Tair A (2001) Explosive spalling of high strength concrete columns in fire. Mag Concr Res 53(3):197–20410.1680/macr.2001.53.3.197 ↗
5. Martins A, Rodrigues JPC (2012) Fire behavior of concrete columns with restrained thermal elongation. J Struct Fire Eng 2(4):319–33210.1260/2040-2317.2.4.319 ↗
6. Franssen JM (2000) Design of concrete columns based on EC2 tabulated data- a critical review. First International Workshop Structures in Fire, Copenhagen
7. prEN 1992–1–2: Eurocode 2 (2002) Design of concrete structures. Part 1–2: General rules-structural fire design. prEN 1992–1–2: Eurocode 2, Brussels
8. Allen DE, Lie TT (1974) Further studies of the fire resistance of reinforced concrete columns. NRCC 14047, Ottawa, 416.
9. Lie TT, Irwin RJ (1993) Method to calculate the fire resistance of reinforced concrete columns with rectangular cross section. ACI Struct J 90(1):52–60
10. Kodur VKR, Cheng FP, Wang TC (2004) Predicting the fire resistance behavior of high strength concrete columns. Cement Concr Compos 26(4):141–15310.1016/S0958-9465(03)00089-1 ↗
11. El-Fitiany S, Youssef MA (2009) Assessing the flexural and axial behavior of reinforced concrete members at elevated temperatures using sectional analysis. Fire Saf J 44(5):691–70310.1016/j.firesaf.2009.01.005 ↗
12. Raut N, Kodur VKR (2011) Response of reinforced concrete columns under fire-induced biaxial bending. ACI Struct J 108(5):610–619
13. El-Fitiany S, Youssef MA (2018) Practical method to predict the axial capacity of RC columns exposed to fire. J Struct Fire Eng 9(4):266–28610.1108/JSFE-08-2016-0015 ↗
14. El-Fitiany S, Youssef MA (2014) Interaction diagrams for fire exposed reinforced concrete sections. Eng Struct J 70(1):246–25910.1016/j.engstruct.2014.03.029 ↗
15. Sadaoui A, Illouli S, Khennane A (2013) Effect of restraints on the response of RC columns in a parametric fire. 8th International conference on fracture mechanics of concrete and concrete structures, FraMCoS-8, Toledo, Spain.
16. Wang LJ, Caspeele R, Taerwe L (2015) Effect of imperfections on concrete columns subjected to fire taking into account second order effects. Concrete – Innovation and Design, fib Symposium, Copenhagen .
17. prEN 1992–1–1: Eurocode 2 (2004) Design of Concrete Structures. Part 1–1: General rules and rules for buildings. prEN 1992–1–1: Eurocode 2, Brussels
18. Haksever A, (1981–1983) On the relaxation behavior of reinforced concrete columns in case of fire. SFB Report, Technical University of Braunschweig.
19. Wu B, Xu YY (2009) Behavior of axially-and-rotationally restrained concrete columns with ‘+’-shaped cross section and subjected to fire. Fire Saf J 44:212–21810.1016/j.firesaf.2008.07.003 ↗
20. Ali F, Nadjai A, Choi S (2010) An Experimental and numerical study on the behavior of high strength concrete columns in fire subjected to high restraint. J Struct Fire Eng 1(1):1–1610.1260/2040-2317.1.1.1 ↗
21. Martins AMB, Rodrigues JPC (2011) Fire behavior of concrete columns with restrained thermal elongation. J Struct Fire Eng 2:319–33110.1260/2040-2317.2.4.319 ↗
22. Haksever A (2017) Experimental and computational research on the fire behavior of restrained reinforced concrete columns-Part II. Trakya Univ J Eng Sci 18(2):121–136
23. Hurst JP, Ahmed GN (1999) Modeling pore pressure, moisture, and temperature in high-strength concrete columns exposed to fire. Fire Technol 35(3):232–26210.1023/A:1015436510431 ↗
24. Mahmoud KA, Abdel-Rahman AK (2013) Two-dimensional thermal and structural modeling of HSC columns exposed to fire. Arab J Sci Eng 38:2009–202210.1007/s13369-012-0341-z ↗
25. Mahmoud KA (2020) behavior of slender RC columns bent in single and double curvature at elevated temperatures. Fire Technol. https://doi.org/10.1007/s10694-020-01057-y10.1007/s10694-020-01057-y ↗
26. ASTM-E119 (2007) Standard test methods for fire tests of building construction and materials. ASTM International, West Conshohocken, PA.
27. ASCE Manual (1992) Structural Fire Protection. American Society of Civil Engineers, New York No. 78:1-241