External Wind Effect on Flame Behavior Inside and Outside a Compartment with Opposing Openings
Source abstract
Abstract
This paper is to quantify the external wind effects on flame behavior evolutions inside and outside a compartment with opposing openings. Temperature profiles at the windward and leeward corners inside the compartment as well as the external flame trajectories were investigated. Experimental results show that the flame shape inside the compartment changes from the windward symmetrical rotation flame to the leeward deflection flame, as the heat release rate increases or the external wind velocity decreases. It results from the competition between the buoyancy force of fire plume and the wind-driven flow field. Two external flame shapes, the horizontally ejected fire and spill-like plume, take place in sequence with decreasing wind velocity. The trajectory of horizontally ejected fire is perpendicular to the building facade. By validating coordinate values of trajectory databases for the spill-like plume, prediction correlations for the trajectory are developed with a notion of the physical process.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire dynamics and safety research · Evacuation and Crowd Dynamics · Wind and Air Flow Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (46)
Show source-provided references
1. Yik FW, Lo TY, Burnett J (2003) Wind data for natural ventilation design in Hong Kong. Build Serv Eng Res Technol 24:125–13610.1191/0143624403bt060tn ↗
2. Mattsson B (2006) The influence of wind speed, terrain and ventilation system on the air change rate of a single-family compartment. Energy 31(5):719–73110.1016/j.energy.2005.04.008 ↗
3. Rong L, Liu D, Pedersen EF et al (2015) The effect of wind speed and direction and surrounding maize on hybrid ventilation in a dairy cow building in Denmark. Energy Build 86:25–3410.1016/j.enbuild.2014.10.016 ↗
4. Rigakis N, Katsoulas N, Teitel M et al (2015) A simple model for ventilation rate determination in screenhouses. Energy Build 87:293–30110.1016/j.enbuild.2014.11.057 ↗
5. Welker JR, Pipkin OA, Sliepcevich CM (1965) The effect of wind on flames. Fire Technol 1:122–12910.1007/BF02588482 ↗
6. Yamaguchi J, Tanaka T (2005) Temperature profiles of window jet plume. Combust Sci Technol 24:17–38
7. Kerber S, Madryzkowski D (2009) Fire fighting tactics under wind driven conditions: 7-story building experiments. Natl Inst Stand Technol, Gaithersburg, MD10.6028/NIST.TN.1629 ↗
8. Chen H, Liu N, Zhang L, Deng Z et al (2008) Experimental study on cross-ventilation compartment fire in the wind environment. In: proceedings of the ninth international symposium, Int Assoc Fire Saf Sci. pp. 907–918.10.3801/IAFSS.FSS.9-907 ↗
9. Karlsson B, Quintiere J (1999) Enclosure fire dynamics. CRC Press10.1201/9781420050219 ↗
10. Gao W, Liu N, Delichatsios M et al (2016) Fire spill plume from a compartment with dual symmetric openings under cross wind. Combust Flame 167:409–42110.1016/j.combustflame.2016.01.011 ↗
11. Yokoi S (1960) Trajectory of hot gas ejected from a window of a burning concrete building. Rep Build Res Inst 34:89
12. Ohmiya Y, Yusa S, Suzuki JI et al (2003) Aerothermo-dynamics of fully involved enclosure fires having external flames. In: 4th Int. Semin. Fire Explosion Hazard: 121–129
13. Oleszkiewicz I (1989) Heat transfer from a window fire plume to a building façade. Asme Htd 123:163–170
14. Lee YP, Delichatsios MA, Ohmiya Y (2012) The physics of the outflow from the opening of an enclosure fire and re-examination of Yokoi’s correlation. Fire Saf 49:82–8810.1016/j.firesaf.2012.01.001 ↗
15. Lee YP, Delichatsios MA, Silcock GWH (2007) Heat fluxes and flame heights in facades from fires in enclosures of varying geometry. Proc Combust Inst 31:2521–252810.1016/j.proci.2006.08.033 ↗
16. Chen H, Liu N, Chow W (2009) Wind effects on smoke motion and temperature of ventilation-controlled fire in a two-vent compartment. Build Environ 44:2521–252610.1016/j.buildenv.2009.04.008 ↗
17. Li Y, Delsante A (2001) Natural ventilation induced by combined wind and thermal forces. Build Environ 36:59–7110.1016/S0360-1323(99)00070-0 ↗
18. Ji J, Li M, Li K et al (2015) Ambient wind effect on combustion characteristics in compartment with simultaneous door and window opened. Energy Build 105:217–22510.1016/j.enbuild.2015.07.046 ↗
19. Lambert K (2014) Positive pressure ventilation in underground systems–an experimental and modelling study. IMFSE Dissertation, School of Engineering, The University of Edinburgh
20. Li M, Gao Z, Ji J et al (2017) Wind effects on flame projection probability from a compartment with opposing openings. Fire Saf 91:414–42110.1016/j.firesaf.2017.04.037 ↗
21. Himoto K, Tsuchihashi T, Tanaka Y et al (2009) Modeling the trajectory of window flames with regard to flow attachment to the adjacent wall. Fire Saf J 44:250–25810.1016/j.firesaf.2008.06.007 ↗
22. Heskestad G (1972) Modeling of enclosure fires, in: proceedings of the fourteenth symposium (International) on combustion, the combustion institute, The Pennsylvania State University, USA
23. Vaux S, Pre´trel H, (2013) Relative effects of inertia and buoyancy on smoke propagation in confined and force d ventilated enclosure fire scenarios. Fire Saf. 62:206–22010.1016/j.firesaf.2013.01.013 ↗
24. Johansson N, Svensson S, Hees PV (2015) An evaluation of two methods to predict temperatures in multi-room compartment fires. Fire Saf. 77:46–5810.1016/j.firesaf.2015.07.006 ↗
25. Ji J, Li LJ, Shi WX et al (2013) Experimental investigation on the rising characteristics of the fire-induced buoyant plume in stairwells. Int J Heat Mass Transf 64:193–20110.1016/j.ijheatmasstransfer.2013.04.030 ↗
26. Li M, Gao Z, Ji J et al (2020) Wind effects on transition and extension characteristics of the external flame projecting from a compartment with opposing openings. Fire Saf J 10310210.1016/j.firesaf.2020.103102 ↗
27. Luo M (1997) Effects of radiation on temperature measurement in a fire environment. J Fire Sci 15(6):443–46110.1177/073490419701500602 ↗
28. Ji J, Fu Y, Li K et al (2015) Experimental study on behavior of sidewall fires at varying height in a corridor-like structure. Proc Combust Inst 35(3):2639–264610.1016/j.proci.2014.06.041 ↗
29. McCaffrey BJ, Heskestad G (1976) A robust bidirectional low-velocity probe for flame and fire application. Combust Flame 26:125–12710.1016/0010-2180(76)90062-6 ↗
30. Moffat RJ (1988) Describing the uncertainties in experimental results. Exp Therm Fluid Sci 1(1):3–1710.1016/0894-1777(88)90043-X ↗
31. Liu C, Ding L, Jangi M, Ji J, Yu L, Wan H (2020) Experimental study of the effect of ullage height on flame characteristics of pool fires. Combust Flame 216:245–25510.1016/j.combustflame.2020.03.009 ↗
32. Ji J, Ge F, Qiu T (2020) Experimental and theoretical research on flame emissivity and radiative heat flux from heptane pool fires. Proceedings of the Combustion Institute10.1016/j.proci.2020.05.052 ↗
33. Kerrison L, Galea ER, Hoffmann N et al (1994) A comparison of a FLOW3D based fire field model with experimental room fire data. Fire Saf J 23:387–41110.1016/0379-7112(94)90005-1 ↗
34. Wen JX, Kang K, Donchev T et al (2007) Validation of FDS for the prediction of medium-scale pool fires. Fire Saf 42:127–13810.1016/j.firesaf.2006.08.007 ↗
35. McGrattan KB, Baum HR, Rehm RG (1998) Large eddy simulations of smoke movement. Fire Saf 30:161–17810.1016/S0379-7112(97)00041-6 ↗
36. Hadjisophocleous G, Jia Q (2009) Comparison of FDS prediction of smoke movement in a 10-storey building with experimental data. Fire Technol 45:163–17710.1007/s10694-008-0075-3 ↗
37. Tilley N, Merci B (2009) Application of FDS to adhered spill plumes in atria. Fire Technol 45:179–18810.1007/s10694-008-0079-z ↗
38. K McGrattan S Hostikka J Floyd et al (2013) Fire dynamics simulator (version6) National Institute of Standards and Technology Report, NIST special publication Users' Guide
39. Zhao G, Beji T, Merci B (2017) Study of FDS simulations of buoyant fire-induced smoke movement in a high-rise building stairwell. Fire Saf 91:276–28310.1016/j.firesaf.2017.04.005 ↗
40. KD Steckler JG Quintiere WJ Rinkinen (1982) Flow induced by fire in a compartment. Symposium (international) on combustion Elsevier, 19(1):913-92010.1016/S0082-0784(82)80267-1 ↗
41. Himoto K, Tsuchihashi T, Tanaka Y et al (2009) Modeling thermal behaviors of window flame ejected from a fire compartment. Fire Saf 44:230–24010.1016/j.firesaf.2008.06.005 ↗
42. Lu KH (2012) Studies on facade flame entrainment and flame height from a compartment under various opening and side wall constraint boundary conditions, University of Science and Technology of China, Hefei (Ph.D. Thesis)
43. Otsu N (1979) A threshold selection method from gray-level histograms. IEEE Trans Syst Man Cybern 9:62–6610.1109/TSMC.1979.4310076 ↗
44. Wan H, Gao Z, Ji J, Wang L, Zhang Y (2019) Experimental study on merging behaviors of two identical buoyant diffusion flames under an unconfined ceiling with varying heights. Proc Combust Inst 37(3):3899–390710.1016/j.proci.2018.05.154 ↗
45. Parker GW (1977) Projectile motion with air resistance quadratic in the speed, American. J Phys 45:606–610
46. Desanghere S (2006) Détermination des conditions d’échauffement de structure extérieure à un bâti-ment en situation d’incendie. Energie électrique, INSA de Rouen, Français