Review of the NRC Canada Studies on Fire Resistance of Walls: Results, Research Gaps and Design Guidelines
Source abstract
Abstract
Abstract The National research council Canada conducted three major fire resistance studies on the interior party walls, interior fire separation walls and exterior walls. The fire resistance results of these studies were published over the past three decades and the publications were short in suggesting design guidelines for practioners’ use and gaps for future research. This paper summaries the fire resistance results of 35 full-scale wall tests, suggests design guidelines and identifies future research gaps for interior party walls, interior fire separation walls and exterior walls. The result summary includes the effect of different design parameters on the fire resistance performance of wall assemblies such as the stud type and spacing, number of stud rows, number of gypsum board layers and thickness, mid-height blocking, resilient channels installation and spacing, screws spacing for attaching gypsum board to either wall faming or resilient channels, insulation type and exterior wall sheathing type on the fire resistance of loadbearing and non-loadbearing wall assemblies. The summary results was used as the basis for suggesting design guidelines for practioners’ use and identifying gaps for future research to improve the fire resistance performance of wall assemblies. For example, the use of a reduced screw spacing from 406 mm o.c. to 203 mm o.c. in the gypsum board field and from 406 mm o.c. to 150 mm o.c. at the board joints was suggested for future research to keep the protective gypsum board layer attached to studs or resilient channels longer for a better fire resistance performance of wall assemblies. Also, fire resistance design guidelines are suggested, for examples, the use of rock fibre insulation for non-load bearing interior party walls to achieve 1.5-h fire resistance, the use of cellulose fibre insulation for loadbearing fire separation walls to achieve 2-h fire resistance rating and the use of reduced screw spacing in attaching the gypsum board to wall framing from 406 mm o.c. to 203 mm o.c. for loadbearing exterior wall assembly with gypsum board glass mat sheathing to expand the fire resistance rating from non-useful 30-min to a useful code compliance 45-min fire resistance rating assembly. Additional suggested examples for future research gaps and design guidelines are also provided.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Fire effects on concrete materials · Fire dynamics and safety research · Structural Response to Dynamic Loads
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (16)
Show source-provided references
1. National Building Code of Canada (1990) National Research Council Canada, Ottawa
2. Sultan M, Lougheed G (2002) Results of fire resistance test on full-scale gypsum board wall assemblies, Internal Report 833. National Research Council Canada, Ottawa
3. Kodur V, Sultan M, Latour J, Leroux P, Monette R (2013) Experimental studies on the fire resistance of load-bearing steel stud walls, Research Report 343. National Research Council Canada, Ottawa
4. Sultan M, Adelzadeh M (2019) Fire-resistance performance of building assembles-results of 13 full-scale wall assemblies’ tests, National Research Council Canada, Report Const-56340E, Ottawa
5. Quirt D, Warnock A, Birta J (1995) Summary report for consortium on gypsum board walls: Sound transmission results, National Research Council Canada, IRC-IR-693
6. Warnock A, Quirt J (1997) Control of sound transmission through gypsum board walls, National Research Council Canada, Construction Technology Update
7. National Building Code of Canada (2000) National Research Council Canada, Ottawa
8. National Building Code of Canada (2005) National Research Council Canada, Ottawa
9. National Building Code of Canada (2020) to be published, National Research Council Canada, Ottawa
10. ULC listing (2020) Design W308-BxUVC, Underwriters’ Laboratories of Canada, Scarborough, ON
11. ULC listing (2020) Design U356-BxUVC, Underwriters’ Laboratories of Canada, Scarborough, ON
12. CAN/S101-M89 (1989) Standard Methods of fire endurance tests of building materials Underwriter’s’ Laboratories of Canada, Scarborough, ON
13. Lie TT, Berndt JE (1972) Remote measuring of large deflections in fire tests, Division of Building Research, National Research Council Canada, Building Research Note No. 84
14. CAN/CSA—A82.31-M91 (1991) Gypsum board application, Canadian Standards Association, Rexdale, ON
15. Sultan M (2020) Fire resistance of wood stud wall assemblies. Fire Mater. https://doi.org/10.1002/fam.291810.1002/fam.2918 ↗
16. Sultan MA (2021) Fire resistance of exterior wall assemblies for housing and small buildings. Fire Technol 57:699–72010.1007/s10694-020-01015-8 ↗