Abstract National Fire Protection Association standard 1403 provides the fire service with guidance for conducting effective live fire training with the goal of minimizing health and safety hazards. The document provides guidelines for materials to be included in the training fuel package, but the fire service has raised questions about the use of specific types of wood products for this purpose. In this study, the fire dynamics generated when utilizing five different Class A materials that have been historically employed as training fuels [low density wood fiberboard, oriented strand board (OSB), pallets, particle board, plywood] in a single compartment fire training structure (Fire Behavior Lab) were characterized. A specific focus was placed on understanding the thermal and visual environment created for firefighters located at typical locations for instructors (front and rear of structure) and students (middle of the structure). The pallet fuel package required the longest time to transition through the six ventilation cycles while the OSB fuel package was the quickest. Additionally, the most consistent fire dynamics were demonstrated with the OSB fuel followed by particle board and plywood, while fiberboard and pallets resulted in less repeatable flashover or rollover demonstration. The OSB fuel package resulted in the highest peak heat fluxes and pallets resulted in the lowest. The most severe exposures were measured at the front instructor location. To control thermal risks when conducting training in the Fire Behavior Lab structure, instructors and students should orient themselves as low as possible in the observation area and behind the interior baffle when possible. Considering the high radiant exposures for the front instructor location, providing a local shield and reducing the time in the training structure can also reduce risk for thermal injury or personal protective equipment damage. Overall, different fuels can impact thermal exposures to firefighters, but varying fuels also affects the consistency of the fire dynamics being presented to the firefighting students.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Occupational Health and Performance · Fire dynamics and safety research · Transportation Safety and Impact Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (33)
Show source-provided references
1. NFPA 1403 (2018) Standard on live fire training evolutions. National Fire Protection Association, Quincy, Massachusetts. National Fire Protection Association
2. IAFF Division of Occupational Health, Safety and Medicine (2018) Dangers of OSB Burning Summary. Technical report, International Association of Firefighters, Department of Occupational Health, Safety and Medicine, Washington, D.C.
3. Regan JW (2021) Heat release rate characterization of NFPA 1403 compliant training fuels. Fire Technol 57:1847–186710.1007/s10694-021-01092-3 ↗
4. Horn GP, Stewart JW, Kesler RM, DeBlois JP, Kerber S, Fent KW, Scott WS, Fernhall B, Smith DL (2019) Firefighter and fire instructor’s physiological responses and safety in various training fire environments. Saf Sci 116:287–29410.1016/j.ssci.2019.03.017 ↗
5. Petrakis JG (2003) Firefighter learning styles and training: beyond the slide presentation. Fire Eng 156(10):132–6
6. Madrzykowski D (2007) Fatal training fires: fire analysis for the fire service. In: INTERFLAM 2007 Proceedings. Interscience Communications Ltd, London
7. Tarley J, Messanotte T (2001) Volunteer fire fighter dies and two others are injured during live-burn training—New York. Technical Report NIOSH F2001-38, National Institute for Occupational Safety and Health, Division of Physical Sciences and Engineering, Cincinnati, Ohio
8. Romano N, Tarley J (2002) Career lieutenant and fire fighter die in a flashover during a live-fire training evolution—Florida. NIOSH F2002-34, National Institute for Occupational Safety and Health, Division of Physical Sciences and Engineering, Cincinnati, Ohio
9. Tarley J (2007) Career probationary fire fighter dies while participating in a live-fire training evolution at an acquired structure—Maryland. NIOSH F2007-09, National Institute for Occupational Safety and Health, Division of Physical Sciences and Engineering, Cincinnati, Ohio
10. Fisher G (2015) Conducting NFPA 1403-compliant live burn training in acquired structures. Fire Eng. https://www.fireengineering.com/fire-prevention-protection/conducting-nfpa-1403-compliant-live-burn-training-in-acquired-structures-p1. Accessed 22 May 2023
11. Reeder F (2013) The NFPA 1403 debate. Fire Rescue. https://www.firefighternation.com/firerescue/the-nfpa-1403-debate. Accessed 22 May 2023
12. Garcia K, Kauffman R (2009) Realistic live burn training you can afford. Fire Eng 162(5):89
13. Horn, GP, Stakes, K, Neumann, DL, Madrzykowski D, Fent KW (2023) Exposure risks and potential control measures for a fire behavior lab training structure: Part B—chemical gas concentrations. Fire Technol submitted for review10.1007/s10694-023-01414-7 ↗
14. Loikkanen P, Mangs J (1991) Flash over simulator, function and safe use. FOU Report P21-069/91, Technical Research Centre of Finland, Espoo
15. Blevins LG (1999) Behavior of bare and aspirated thermocouples in compartment fires. In: National Heat Transfer Conference, 33rd Proceedings, pp. 15–1710.6028/NIST.IR.6310 ↗
16. Pitts WM, Braun E, Peacock R, Mitler H, Johnson E, Reneke P, Blevins LG (2003) Temperature uncertainties for bare-bead and aspirated thermocouple measurements in fire environments. ASTM Special Techn Pub 1427:3–15
17. Pitts WM, Murthy AV, de Ris JL, Filtz J, Nygård K, Smith D, Wetterlund I (2006) Round robin study of total heat flux gauge calibration at fire laboratories. Fire Saf J 41(6):459–47510.1016/j.firesaf.2006.04.004 ↗
18. Kerber S, Madrzykowski D (2008) Evaluating positive pressure ventilation in large structures: school pressure and fire experiments. NIST Technical Note 1498, National Institute of Standards and Technology, Gaithersburg, MD10.6028/NIST.TN.1498 ↗
19. Bundy M, Hamins A, Johnsson EL, Kim SC, Ko GH, Lenhart DB (2007) Measurements of heat and combustion products in reduced-scale ventilated-limited compartment fires. NIST Technical Note 1483, National Institute of Standards and Technology, Gaithersburg, MD10.6028/NIST.TN.1483 ↗
20. Lock A, Bundy M, Johnsson EL, Hamins A, Ko GH, Hwang C, Fuss P, Harris R (2008) Experimental study of the effects of fuel type, fuel distribution, and vent size on full-scale underventilated compartment fires in an ISO 9705 room. NIST Technical Note 1603, National Institute of Standards and Technology, Gaithersburg, MD10.6028/NIST.TN.1603 ↗
21. Mayer AC, Fent KW, Wilkinson A, Chen I, Kerber S, Smith DL, Kesler RM, Horn GP (2022) Characterizing exposure to benzene, toluene, and naphthalene in firefighters wearing different types of new or laundered PPE. Int J Hyg Environ Health. https://doi.org/10.1016/j.ijheh.2021.11390010.1016/j.ijheh.2021.113900 ↗
22. Duffy RM, Sawicki JC, Beer AR (1985) Project fires: firefighters integrated response equipment system—The Final Report. Technical report, International Association of Firefighters, Department of Occupational Health and Safety, Washington, D.C.
23. Foster JA, Roberts GV (September 1995) Measurements of the firefighting environment—summary report. 61, Central Fire Brigades Advisory Council Research, United Kingdom
24. Colletta GC, Arons IJ, Ashley LE, Drennan AP (February 1976) The Development of Criteria for Firefighters’ Gloves Volume I: Glove Requirements. Technical report, U. S. Department of Health, Education, and Welfare, Public Health Service, Center for Disease Control, National Institute for Occupational Safety and Health, Division of Physical Sciences and Engineering, Cincinnati, Ohio
25. Donnelly MK, Davis WD, Lawson JR, Selepak MJ (January 2006) Thermal environment for electronic equipment used by first responders. NIST TN 1474, National Institute of Standards and Technology, Gaithersburg, MD
26. Utech H (1973) Status report on research programs for firefighters protective clothing. In: 45th Annual Fire Department Instructors Conference Proceedings, pp. 156–166. International Society of Fire Service Instructors, Kansas City, MO
27. Madrzykowski D (2017) Fire fighter equipment operational environment: evaluation of thermal conditions. NFPA Fire Protection Research Foundation, Quincy, Massachussets10.54206/102376/IGFM4492 ↗
28. Willi J, Horn G, Madrzykowski D (2016) Characterizing a firefighter’s immediate thermal environment in live-fire training scenarios. Fire Technol 52:1667–169610.1007/s10694-015-0555-1 ↗
29. NFPA 1981 (2019) Standard on Open-Circuit Self-Contained Breathing Apparatus (SCBA) for Emergency Services. National Fire Protection Association, Quincy, Massachusetts. National Fire Protection Association
30. Putorti A, Mensch A, Bryner N, Braga G (2013) Thermal performance of self-contained breathing apparatus facepiece lenses exposed to radiant heat flux. Technical Report NIST TN 1785, National Institute of Standards and Technology, Gaithersburg, MD10.6028/NIST.TN.1785 ↗
31. Horn G, Kesler R, Regan J, Madrzykowski D (2017) A study on the effect of repeat moderate intensity radiant exposures on SCBA facepiece properties. NISTGCR 17-014, National Institute of Standards and Technology10.6028/NIST.GCR.17-014 ↗
32. Kesler R, Mitsingas C, Quiat A, Lee T, Madrzykowski D, Horn G (2018) Mechanical properties and off-gassing characteristics of new and legacy facepieces. NISTGCR 18-019 Natl Inst Stand Technol. https://doi.org/10.6028/NIST.GCR.18-01910.6028/NIST.GCR.18-019 ↗
33. Randall GB (2020) Characterization of a Live-Fire Training Simulator for use in the Canadian Fire Service. Master’s thesis, University of Waterloo