On the Local Buckling of Steel “I” Profiles in a Fire Situation
Source abstract
Abstract
Although the fire resistance of various steel profiles has been predicted and presented in the literature, the effect of local buckling requires further research. This comprehensive study discusses this effect on the fire resistance of steel “I” slender cross-sections for uniform compression and simple bending cases. A numerical modelling analysis with SAFIR considering the ABNT NBR 14.323:2013 and Eurocode 3 Part 1-2 (2005) design rules is conducted. For the catalogue profiles, the standards are conservative for columns and beams for a temperature range between 600.00°C and 800.00°C and 400.00°C and 800.00°C, respectively. However, the results determined with the standards may be unsafe. The need for an improvement in the precision of the current standards is also discussed.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Load-Bearing Analysis · Fire effects on concrete materials · Structural Behavior of Reinforced Concrete
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. Associação Brasileira de Normas Técnicas (2013) NBR 14.323: Projeto de estruturas de aço e de estruturas mistas de aço e concreto de edifícios em situação de incêndio. Rio de Janeiro
2. British Standards Institution (2005) BS EN 1993-1-2: Eurocode 3: design of steel structures—Part 1-2: general rules—structural fire design. United Kingdom
3. Knobloch M (2008) Local buckling behavior of steel sections subjected to fire. Fire Saf Sci 9:1239–1254. 10.3801/iafss.fss.9-123910.3801/iafss.fss.9-1239 ↗
4. Zhao B, Oly R, Morente F, Real PV, Wald F, Franssen JM, Velda P (2014) Fire design of steel members width welded or hot-rolled class 4 cross-section (FIDESC4). RFCS-CT-2011-00030, 2011-2014, Technical Report No. 5. Luxembourg
5. Couto C, Real PV, Lopes N, Zhao B (2015) Resistance of steel cross-sections with local buckling at elevated temperatures. J Constr Steel Res 109:101–114. https://doi.org/10.1016/j.jcsr.2015.03.00510.1016/j.jcsr.2015.03.005 ↗
6. Maraveas C (2019) Local buckling of steel members under fire conditions: a review. Fire Technol 55:51–80. 10.1007/s10694-018-0768-110.1007/s10694-018-0768-1 ↗
7. Franssen J-M (2005) SAFIR: a thermal/structural program for modelling structures under fire. Eng J Am Inst Steel Constr 42:143–158
8. Associação Brasileira de Normas Técnicas (2008) NBR 8.800: Projeto de Estruturas de Aço e Estruturas Mistas de Aço e Concreto de Edifícios. Rio de Janeiro
9. Associação Brasileira de Normas Técnicas (2010) NBR 14.762: Dimensionamento de Estruturas de Aço Constituídas por Perfis Formados a Frio. Rio de Janeiro
10. British Standards Institution (2006) BS EN 1993-1-5: Eurocode 3: design of steel structures—part 1–5: plated structural elements. United Kingdom
11. AISC Committee et al (2010) Specification for structural steel buildings (ANSI/AISC 360-10). American Institute of Steel Construction, Chicago
12. AISC Committee et al (2016) Specification for structural steel buildings (ANSI/AISC 360-16). American Institute of Steel Construction. Chicago
13. American Iron and Steel Institute (2007) North American specification for the design of cold-formed steel structural members. American Iron & Steel Institute, Committee of Steel Plate Producers & Committee of Stainless Steel Producers
14. British Standards Institution (2005) BS EN 1993-1-1: Eurocode 3: design of steel structures—part 1–1: general rules and rules for buildings. United Kingdom
15. Von Karman T, Sechler EE, Donnell LH (1932) The strength of thin plates in compression. Trans Am Soc Mech Eng 52:53–5710.1115/1.4021738 ↗
16. Winter G (1947) Performance of thin steel compression flanges. Trans ASCE 112:527–554
17. Yu WW, Laboube RA (2010) Cold-formed steel design, 4th edn. Wiley, Hoboken10.1002/9780470949825 ↗
18. Ranawaka T, Mahendran M (2009) Experimental study of the mechanical properties of light gauge cold-formed steels at elevated temperatures. Fire Saf J 44(2):219–229. https://doi.org/10.1016/j.firesaf.2008.06.00610.1016/j.firesaf.2008.06.006 ↗
19. Landesmann A, Camotim D (2011) On the distortional buckling, post-buckling and strength of cold-formed steel lipped channel columns under fire conditions. J Struct Fire Eng 2(1):1–19. https://doi.org/10.1260/2040-2317.2.1.110.1260/2040-2317.2.1.1 ↗
20. Association Française de Normalisation (2007) Annexe Nationale à la NF EN 1993-1-2:2005: Règles générales—Calcul du comportement au feu. France
21. ADINA, AUI. 9.2 (2015) “User Interface Primer and AUI Command Reference Manual” ADINA R & D Inc, Watertown, MA
22. Franssen JM (2013) FIDESC4: fire behaviour of steel members with class 4 cross sections under axial compression and axial compression with eccentricity: report of the experimental tests performed at the University of Liège. Belgium, p 78
23. Associação Brasileira de Normas Técnicas (2013) NBR 5.884: Perfil I estrutural de aço soldado por arco elétrico—equisitos gerais. Rio de Janeiro
24. GERDAU (Brasil) (Org.). Catálogo de produtos. https://www.comercialgerdau.com.br/pt/productsservices/products/DocumentGallery/catalogo-produtos-cg.pdf. Accessed 12 July 2017
25. Quiel SE, Garlock MEM (2010) Calculating the buckling strength of steel plates exposed to fire. Thin-Walled Struct 48:684–695. https://doi.org/10.1016/j.tws.2010.04.00110.1016/j.tws.2010.04.001 ↗
26. Couto C, Real PV, Lopes N, Zhao B (2014) Effective width method to account for the local buckling of steel thin plates at elevated temperatures. Thin-Walled Struct 84:134–149. https://doi.org/10.1016/j.tws.2014.06.00310.1016/j.tws.2014.06.003 ↗
27. Tide RHR (1998) Integrity of structural steel after exposure to fire. Eng J Am Inst Steel Constr 35:26–38