journal article·2024-05

Fire Dynamics of Mass Timber Compartments with Exposed Surfaces: Development of an Analytical Model

Luc Girompaire, Christian Dagenais

Fire Technology· Volume 60· Issue 3
Publisher page

Abstract

Exposed timber in buildings has proven to have a positive effect on the building’s sustainability, occupant wellness, and increases the aesthetic appeal of the building but is currently limited by most building codes mainly due to fire safety concerns. While compartment fire testing can be carried out to prove a design performance, this approach is costly and time consuming. Models predicting the fire dynamics inside mass timber compartment with exposed surfaces were developed over the last years. The charring rate of the timber elements, in these models, is either the charring rate of timber when exposed to standard fire or the displacement of the 300°C isotherm using finite element analysis involving several parameters to be determined. Furthermore, using the 300°C isotherm does not account for the impact of the oxygen concentration on the charring rate. In this study, a two-zone model has been developed to estimate the heat release rate (HRR), the upper-layer temperature and oxygen concentration, and the char depth of the exposed timber elements during compartment fires. The charring rate is determined as a function of the incident heat flux impinging on the surface and the oxygen concentration. Comparing the model predictions to 20 experimental compartment fires with and without exposed timber surfaces shows that the model captures well the general fire dynamic, i.e., HRR and temperature. The char depth predictions are close to the experimental data, while being mostly conservative. Seven limitations and improvements have been discussed and will be considered in future versions of this model.
Source: expertdata · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire dynamics and safety research · Fire effects on ecosystems · Wind and Air Flow Studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (42)

Show source-provided references
1. Fell DR (2010) Wood in the human environment: restorative properties of wood in the built indoor environment. PhD Thesis University of British Columbia
2. Watchman M, Potvin A, Demers CMH (2017) A post-occupancy evaluation of the influence of wood on environmental comfort. BioResources 12(4):8704–872410.15376/biores.12.4.8704-8724 ↗
3. McGregor CJ (2013) Contribution of cross laminated timber panels to room fires. Master’s Thesis Carleton University, p. 185
4. Medina Hevia AR (2014) Fire resistance of partially protected cross laminated timber rooms. Master’s Thesis Carleton University, p. 199
5. Su J, Leroux P, Lafrance P-S, et al (2018) Fire testing of rooms with exposed wood surfaces in encapsulated mass timber construction. National Research Council of Canada Report A1-0127101 74
6. Su J, Lafrance P, Hoehler M, Bundy M (2018) Fire safety challenges of tall wood buildings—phase 2: task 2 & 3—cross laminated timber compartment fire tests. National Research Council of Canada, p. 396
7. Brandon D, Sjöström J, Temple A et al (2021) Fire safe implementation of visible mass timber in tall buildings—compartment fire testing. Res Inst Sweden Rep 2021:40
8. Li X, Zhang X, Hadjisophocleous G, McGregor C (2015) Experimental study of combustible and non-combustible construction in a natural fire. Fire Technol 51:1447–1474. https://doi.org/10.1007/s10694-014-0407-410.1007/s10694-014-0407-4 ↗
9. Zelinka SL, Hasburgh LE, Bourne KJ et al (2018) Compartment fire testing of a two-story mass timber building. United States Department of Agriculture, Forest Service, Forest Products Laboratory10.2737/FPL-GTR-247 ↗
10. Kotsovinos P, Rackauskaite E, Christensen E et al (2022) Fire dynamics inside a large and open-plan compartment with exposed timber ceiling and columns: CodeRed\#01. Fire Mater n/a:1–27. https://doi.org/10.1002/fam.304910.1002/fam.3049 ↗
11. Brandon D (2018) Fire safety challenges of tall wood buildings—phase 2: task 4-engineering methods for performance based design. National Fire Protection Association Report FPRF-2018-04 46
12. Brandon D (2016) Practical method to determine the contribution of structural timber to the rate of heat release and fire temperature of post-flashover compartment fires. Tech Res Inst Sweden SP Rep 2016(68):20
13. Brandon D, Anderson J (2018) Wind effect on internal and external compartment fire exposure. Res Inst Sweden Rep 2018:72
14. Brandon D, Temple A, Sjöström J (2021) Predictive method for fires in CLT and glulam structures—a priori modelling versus real scale compartment fire tests & an improved method. Res Inst Sweden Rep 2021:63
15. Wade C, Spearpoint M, Fleischmann C et al (2018) Predicting the fire dynamics of exposed timber surfaces in compartments using a two-zone model. Fire Technol 54:893–920. https://doi.org/10.1007/s10694-018-0714-210.1007/s10694-018-0714-2 ↗
16. Wade C, Hopkin D, Su J, et al (2019) Enclosure fire model for mass timber construction—benchmarking with a kinetic wood pyrolysis submodel. In: Interflam: 15th international conference on fire safety engineering, pp. 1–3
17. Schmid J, Frangi A (2021) Structural timber in compartment fires—the timber charring and heat storage model. Open Eng 11:435–452. https://doi.org/10.1515/eng-2021-004310.1515/eng-2021-0043 ↗
18. Wickstrom U (1985) Application of the standard fire curve for expressing natural fires for design purposes. ASTM Special Technical Publication, pp. 145–159. https://doi.org/10.1520/stp35295s10.1520/stp35295s ↗
19. CEN (2004) EN 1991-1-2—Eurocode 1: actions on structures—Part 1–2: general actions—actions on structures exposed to fire. CEN standards
20. Mikkola E (1990) Charring of wood. Tutkimuksia-Valtion Teknillinen Tutkimuskeskus
21. Just A, Abu A, Barber D et al (2022) Load-bearing timber structures. Fire safe use of wood in buildings. CRC Press, pp 227–27610.1201/9781003190318-7 ↗
22. Bartlett AI, Hadden RM, Bisby LA (2019) A review of factors affecting the burning behaviour of wood for application to tall timber construction. Fire Technol 55:1–49. https://doi.org/10.1007/s10694-018-0787-y10.1007/s10694-018-0787-y ↗
23. Friquin KL (2011) Material properties and external factors influencing the charring rate of solid wood and glue-laminated timber. Fire Mater 35:303–327. https://doi.org/10.1002/fam.105510.1002/fam.1055 ↗
24. Richter F, Rein G (2020) A multiscale model of wood pyrolysis in fire to study the roles of chemistry and heat transfer at the mesoscale. Combust Flame 216:316–325. https://doi.org/10.1016/j.combustflame.2020.02.02910.1016/j.combustflame.2020.02.029 ↗
25. CEN (2004) EN 1995-1-2—Eurocode 5: design of timber structures—Part 1–2: general—actions on structures exposed to fire. CEN standards
26. White RH, Tran HC (1996) Charring rate of wood exposed to a constant heat flux. Wood and fire safety. Technical University Zvolen, Faculty of Wood Technology, Zvolen, Slovak Republic, pp 175–183
27. Barber D (2016) Fire safety engineering of tall timber buildings in the USA. In: WCTE 2016—World conference on timber engineering. World Conference on Timber Engineering, Vienna
28. Staffansson L (2010) Selecting design fires. Department of Fire Safety Engineering and Systems Safety, Lund University
29. Rockett JA (1976) Fire induced gas flow in an enclosure. Combust Sci Technol 12:165–175. https://doi.org/10.1080/0010220760894671710.1080/00102207608946717 ↗
30. Karlsson B, Quintiere JG (2022) Pressure profiles and vent flows for well-ventilated enclosures. Enclosure fire dynamics, 2nd edn. CRC Press, pp 81–11410.1201/b22214 ↗
31. Babrauskas V (2016) Heat release rates. SFPE handbook of fire protection engineering. Springer, pp 799–90410.1007/978-1-4939-2565-0_26 ↗
32. Hadjisophocleous GV, Mehaffey JR (2016) Fire scenarios. SFPE handbook of fire protection engineering. Springer, pp 1262–128810.1007/978-1-4939-2565-0_38 ↗
33. ISO (2006) ISO 16735 Fire safety engineering—requirements governing algebraic equations—Smoke layer. International Standard Geneva, Switzerland: International Organization for Standardization
34. Zukoski Ee (1994) Mass flux in fire plumes. In: Fire safety science—proceedings of the fourth international symposium, IAFSS, p. 1310.3801/IAFSS.FSS.4-137 ↗
35. McCaffrey BJ (1983) Momentum implications for buoyant diffusion flames. Combust Flame 52:149–167. https://doi.org/10.1016/0010-2180(83)90129-310.1016/0010-2180(83)90129-3 ↗
36. Hurley MJ (2016) Appendix 3: fuel properties and combustion data. In: SFPE handbook of fire protection engineering, pp. 3437–3475
37. Schmid J, Santomaso A, Brandon D et al (2018) Timber under real fire conditions—the influence of oxygen content and gas velocity on the charring behavior. J Struct Fire Eng 9:222–236. https://doi.org/10.1108/JSFE-01-2017-001310.1108/JSFE-01-2017-0013 ↗
38. Canadian Wood Council (2022) Mass timber research fire test performed as expected: fire performance similar to non-combustible. https://firetests.cwc.ca/wp-content/uploads/2022/06/Announcemnt_4_Mass_Timber_Fire_Research_Test_Performed-1.pdf. Accessed 30 Mar 2023
39. Brandon D, Dagenais C (2018) Fire safety challenges of tall wood buildings—phase 2: task 5—experimental study of delamination of cross laminated timber (CLT) in fire. National Fire Protection Association Report FPRF-2018-05 74
40. APA (2018) ANSI/APA PRG 320-2018: standard for performance-rated cross-laminated timber. The Engineered Wood Association (APA), p. 40
41. Dagenais C, Ranger L, Benichou N (2019) Fire performance of cross-laminated timber with adhesives conforming to 2018 edition of ANSI/APA PRG-320 (Project No. 301013085). FPInnovations
42. ISO (2019) ISO 24679–1: fire safety engineering performance of structures in fire part 1: general. International Organization for Standardization, Geneva