journal article·2021-05

Behavior of Slender RC Columns Bent in Single and Double Curvature at Elevated Temperatures

Khaled Ahmed Mahmoud

Fire Technology· Volume 57· Issue 3
Publisher page

Abstract

In this study, a numerical model for tracing the behavior of eccentrically loaded slender reinforced concrete (RC) columns bent in single and double curvature, and subjected to elevated temperatures is presented. The developed model incorporates the high-temperature material properties, the nonlinear behavior of concrete sections, time dependent effects, and the nonlinear responses of slender RC columns. Based on Newton–Raphson method, an iterative technique, wherein strain and curvature are concurrently iterated, is used to find the strain distribution on the cross-section. By proposing a simple and reliable calculation procedure, the lateral deflection is calculated using numerical and searching techniques. The compatibility between forces and deformations at a joint in the column is established by another iterative technique, which involves the analysis of the whole column. The validity of the analytical model is established by comparing its predictions with results obtained from laboratory tests found in literature. A parametric study is conducted to investigate the effect of end eccentricity conditions on columns bent in single and double curvatures. It was found that lateral deflection plays an important role on column responses when subjected to fire. This finding confirms the usefulness of lateral deflection as a powerful tool in validating eccentrically loaded slender RC columns. It was also found that unwinding at elevated temperature has detrimental effect on columns bent in double curvature. It was observed that for all columns, there exists a critical eccentricity after which column responses to fire change.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire effects on concrete materials · Structural Behavior of Reinforced Concrete · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (41)

Show source-provided references
1. Broms B, Viest IM (1958) Ultimate strength analysis of long hinged reinforced concrete columns. J Struct Div 84(1):1–3810.1061/JSDEAG.0000187 ↗
2. Pfrang EO, Siess CP (1964) Behavior of restrained reinforced concrete columns. ASCE 90(5):113–136
3. Drysdale RG (1967) The behavior of reinforced concrete columns subjected to sustained biaxial bending. Ph.D thesis, University of Toronto
4. Lie TT, Woollerton JL (1988) Fire safety of reinforced concrete columns. NRCC, Canada, Internal Report No 569
5. Aldea CM, Franssen JM, Dotreppe JC (1997) Fire test on normal and high strength reinforced concrete columns. National Institute of Science and Technology, Gaithersburg
6. Dotreppe JC, Franssen JM, Bruls A, Baus R, Vandevelde P, Minne R, van Nieuwenburg D, Lambotte H (1997) Experimental research on the determination of the main parameters affecting the behavior of reinforced concrete columns under fire conditions. Mag Concr Res 49(179):117–12710.1680/macr.1997.49.179.117 ↗
7. Ali FD, O’Connor D, Abu-Tair A (2001) Explosive spalling of high strength concrete columns in fire. Mag Concr Res 53(3):197–20410.1680/macr.2001.53.3.197 ↗
8. Kodur VKR (2003) Fire resistance design guidelines for high strength concrete columns. In: NRCC, pp 1–11
9. Martins A, Rodrigues JPC (2012) Fire behavior of concrete columns with restrained thermal elongation. J Struct Fire Eng 2(4):319–33210.1260/2040-2317.2.4.319 ↗
10. Martin I, Olivieri E (1966) Tests of slender reinforced concrete columns bent in double curvature. In: Symposium on reinforced concrete columns, ACI SP-13, pp 121–138
11. MacGregor JG, Barter SL (1966) Long eccentrically loaded concrete columns bent in double curvature. In: Symposium on reinforced concrete columns, ACI SP-13, pp 139–156
12. Afefy HM, El-Tony EM (2016) Simplified design procedure for reinforced concrete columns based on equivalent column concept. Int J Concr Struct Mater 10(3):393–40610.1007/s40069-016-0132-0 ↗
13. Franssen JM (2000) Design of concrete columns based on EC2 tabulated data—a critical review. In: First international workshop structures in fire, Copenhagen
14. prEN 1992-1-2: Eurocode 2 (2002) Design of concrete structures. Part 1–2: general rules—structural fire design. prEN 1992-1-2: Eurocode 2, Brussels
15. Raut N, Kodur VKR (2012) A simplified approach for predicting fire resistance of reinforced concrete columns under biaxial bending. Eng Struct 41:428–44310.1016/j.engstruct.2012.03.054 ↗
16. Lie TT, Allen DE (1972) Calculation of fire resistance of reinforced concrete columns. NRCC 12797, Ottawa, 378
17. Allen DE, Lie TT (1974) Further studies of the fire resistance of reinforced concrete columns. NRCC 14047, Ottawa, 416
18. Lie TT, Irwin RJ (1993) Method to calculate the fire resistance of reinforced concrete columns with rectangular cross section. ACI Struct J 90(1):52–60
19. Kodur VKR, Cheng FP, Wang TC (2004) Predicting the fire resistance behavior of high strength concrete columns. Cem Concr Compos 26(4):141–15310.1016/S0958-9465(03)00089-1 ↗
20. El-Fitiany S, Youssef MA (2009) Assessing the flexural and axial behavior of reinforced concrete members at elevated temperatures using sectional analysis. Fire Saf J 44(5):691–70310.1016/j.firesaf.2009.01.005 ↗
21. Raut N, Kodur VKR (2011) Response of reinforced concrete columns under fire-induced biaxial bending. ACI Struct J 108(5):610–619
22. El-Fitiany S, Youssef MA (2018) Practical method to predict the axial capacity of RC columns exposed to fire. J Struct Fire Eng 9(4):266–28610.1108/JSFE-08-2016-0015 ↗
23. Xavier HFB (2009) Analysis of reinforced concrete frames exposed to fire. MSc thesis, University of Porto, Portugal
24. Balaji A, Lukman M, Nagarajan P, Pillai TMM (2016) Prediction of response of reinforced concrete frames exposed to fire. Adv Comput Des 1(1):105–117
25. Dzolev IM, Cvetkovska MJ, Ladinovic DZ, Radonjanin VS (2018) Numerical analysis on the behavior of reinforced concrete frame structures in fire. Comput Concr 21(6):637–647
26. Hurst JP, Ahmed GN (1999) Modeling pore pressure, moisture, and temperature in high-strength concrete columns exposed to fire. Fire Technol 35(3):232–26210.1023/A:1015436510431 ↗
27. Mahmoud KA, Abdel-Rahman AK (2013) Two-dimensional thermal and structural modeling of HSC columns exposed to fire. Arab J Sci Eng 38:2009–202210.1007/s13369-012-0341-z ↗
28. Anderberg Y, Thelandersson S (1976) Stress and deformation characteristics of concrete at high temperatures: 2 experimental investigation and material behavior model. Bulletin 54. Lund Institute of Technology, Lund
29. Anderberg Y (1976) Fire exposed hyberstatic concrete structures—an experimental and theoretical study. Bulletin 55. Lund Institute of Technology, Lund
30. Harmathy TZ (1967) A comprehensive creep model. J Basic Eng 89(2):496–50210.1115/1.3609648 ↗
31. Youssef MA, Moftah M (2007) General stress–strain relationship for concrete at elevated temperatures. Eng Struct 29(10):2618–263410.1016/j.engstruct.2007.01.002 ↗
32. Hognestad E (1951) A study of combined bending and axial load in reinforced concrete members. University of Illinois, Engineering Equipment Station, Bulletin No. 399
33. Rüsch H (1960) Researches toward a general flexural theory for structural concrete. ACI J Proc 32:1–28
34. Carrasquillo RL, Nilson AH, Slate FO (1981) Properties of high-strength concrete subject to short-term loads. ACI J 78(3):171–178
35. Whelan MD (1979) Design provisions of slender concrete columns. MSc thesis, McMaster University, Hamilton
36. Sallam SEA (1974) Design of reinforced concrete columns. MSc thesis, McMaster University, Hamilton
37. American Concrete Institute (ACI) (2014) Building code requirement for reinforced concrete. ACI 318-14, Farmington Hills
38. Lie TT (1989) Fire resistance of reinforced concrete columns: a parametric study. J Fire Prot Eng 1(4):121–12910.1177/104239158900100402 ↗
39. ASTM-E119 (2007) Standard test methods for fire tests of building construction and materials. ASTM International, West Conshohocken
40. ASCE Manual (1992) Structural fire protection. American Society of Civil Engineers, New York, No. 78, pp 1–241
41. Wu B, Xu YY (2009) Behavior of axially-and-rotationally restrained concrete columns with ‘+’-shaped cross-section and subjected to fire. Fire Saf J 44:212–21810.1016/j.firesaf.2008.07.003 ↗