journal article·2022-09

Coupling Characteristics of a Co-flow Water Mist System and Normal Temperature Counter Air Jets

Mingli He, Guang Zhang, Shaohua Hu, Ying Zhang, Cheng Wang

Fire Technology· Volume 58· Issue 5
Publisher page

Abstract

A co-flow water mist system is considered a clean and efficient emergency handling measure for preventing and controlling the leakage of hazardous gas. To reveal the coupling characteristics of a co-flow water mist system and normal temperature counter air jets, a series of 3D numerical simulations were conducted to visualize the gas-phase flow field as well as the instantaneous trajectories, concentration distribution, and penetration of droplets. The results show that the two-phase flow field can be divided into the co-flow jet or counter jet dominant flow for different initial momentum ratios of the counter jets and the co-flow jet Φ′. Φ′ ≤ 1 is necessary to effectively control the leakage flow. A natural exponential function could be used to fit the dimensionless interaction boundary height zb* and the characteristic axial momentum ratio Φ for the scenarios of a co-flow water mist system interacting with counter jets. Moreover, a general design method for the co-flow water mist system which could be utilized to prevent and control the leakage of hazardous gas was proposed. The method was tested by a specific case, which shows that it can be used to guide engineering development.
Source: expertdata · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Wind and Air Flow Studies · Fire dynamics and safety research · Combustion and Detonation Processes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (39)

Show source-provided references
1. Jo YD, Ahn BJ (2003) A simple model for the release rate of hazardous gas from a hole on high-pressure pipelines. J Hazard Mater 97:31–4610.1016/S0304-3894(02)00261-3 ↗
2. Sugiyama Y, Wakabayashi K, Matsumura T et al (2020) Numerical study of the effect of high-explosive storage facility shape on the azimuthal distribution of blast-wave pressures. Eur J Mech B Fluids 79:153–16410.1016/j.euromechflu.2019.09.008 ↗
3. Wu J, Bai Y, Fang W et al (2021) An integrated quantitative risk assessment method for urban underground utility tunnels. Reliab Eng Syst Saf 213:107792. https://doi.org/10.1016/j.ress.2021.10779210.1016/j.ress.2021.107792 ↗
4. Zhang J, Lei D, Feng W (2014) An approach for estimating toxic releases of H2S-containing natural gas. J Hazard Mater 264:350–36210.1016/j.jhazmat.2013.09.070 ↗
5. Koper KD (2003) Seismic recordings of the Carlsbad, New Mexico, pipeline explosion of 19 August 2000. Bull Seismol Soc Am 93(4):1427–143210.1785/0120020192 ↗
6. Jackson RB, Down A, Phillips NG et al (2014) Natural gas pipeline leaks across Washington, DC. Environ Sci Technol 48(3):2051–205810.1021/es404474x ↗
7. Ma H, Long Y, Zhong M, Li X et al (2019) Study on ground vibration mode of physical explosion of high pressure natural gas pipeline. Acoust Phys 65(5):583–59210.1134/S1063771019050142 ↗
8. Liao G, Liu J, Qin J et al (2001) Experimental study on the interaction of fine water spray with liquid pool fires. J Therm Sci 10(4):377. https://doi.org/10.1007/s11630-001-0047-010.1007/s11630-001-0047-0 ↗
9. Liu JH, Liao GX, Fan WC et al (2002) Study of liquid pool fire suppression with water mists by cone calorimeter. J Fire Sci 20(6):465–47710.1177/0734904102020006468 ↗
10. Jayaweera TM, Fisher EM, Fleming JW (2005) Flame suppression by aerosols derived from aqueous solutions containing phosphorus. Combust Flame 141(3):308–32110.1016/j.combustflame.2004.10.013 ↗
11. Zhou XM, Liao GX, Cai B (2006) Improvement of water mist’s fire-extinguishing efficiency with MC additive. Fire Saf J 41(1):39–4510.1016/j.firesaf.2005.08.004 ↗
12. Liang T, Liu M, Liu Z et al (2015) A study of the probability distribution of pool fire extinguishing times using water mist. Process Saf Environ Prot 93:240–24810.1016/j.psep.2014.05.009 ↗
13. Zhou Y, Bu R, Gong J et al (2018) Assessment of a clean and efficient fire-extinguishing technique: continuous and cycling discharge water mist system. J Clean Prod 182:682–69310.1016/j.jclepro.2018.02.046 ↗
14. Rasbash DJ, Rogowski ZW, Stark GWV (1960) Mechanisms of extinction of liquid fires with water sprays. Combust Flame 4:223–23410.1016/S0010-2180(60)80026-0 ↗
15. Wang XS, Liao GX, Qin J et al (2002) Experimental study on the effectiveness of the extinction of a pool fire with water mist. J Fire Sci 20(4):279–29510.2190/L1UP-1A4N-W7T4-DMNT ↗
16. Liu Z, Carpenter D, Kim AK (2008) Cooling characteristics of hot oil pool by water mist during fire suppression. Fire Saf J 43(4):269–28110.1016/j.firesaf.2007.08.004 ↗
17. Ferng YM, Liu CH (2011) Numerically investigating fire suppression mechanisms for the water mist with various droplet sizes through FDS code. Nucl Eng Des 241(8):3142–314810.1016/j.nucengdes.2011.06.002 ↗
18. Zhou X (2015) Characterization of interactions between hot air plumes and water sprays for sprinkler protection. Proc Combust Inst 35(3):2723–272910.1016/j.proci.2014.05.078 ↗
19. Beji T, Ebrahimzadeh S, Maragkos G et al (2018) Numerical modelling of the interaction between water sprays and hot air jets—Part II: two-phase flow simulations. Fire Saf J 96:143–15210.1016/j.firesaf.2018.01.006 ↗
20. Blanchard E, Morlon R, Parent G et al (2018) Experimental study of the interaction between water sprays and smoke layer. Fire Technol 54(2):479–50110.1007/s10694-017-0693-8 ↗
21. Rana MA, Guo YY, Mannan MS (2010) Use of water spray curtain to disperse LNG vapor clouds. J Loss Prev Process Ind 23:77–8810.1016/j.jlp.2009.06.003 ↗
22. Zhu P, Wang XS, Li GC et al (2017) Experimental study on interaction of water mist spray with high-velocity gas jet. Fire Saf J 93:60–7310.1016/j.firesaf.2017.08.005 ↗
23. Liu Z, Kim AK, Carpenter D (2007) A study of portable water mist fire extinguishers used for extinguishment of multiple fire types. Fire Saf J 42(1):25–4210.1016/j.firesaf.2006.06.008 ↗
24. He M, Zhang G, Hu S et al (2021) Assessment of a method to enhance the momentum of water mist: Co-flow jet water mist system. Fire Technol. https://doi.org/10.1007/s10694-021-01128-810.1007/s10694-021-01128-8 ↗
25. Alpert RL (1985) Numerical modeling of the interaction between automatic sprinkler sprays and fire plumes. Fire Saf J 9(2):157–16310.1016/0379-7112(85)90003-7 ↗
26. Prasad K, Li C, Kailasanath K (1999) Simulation of water mist suppression of small scale methanol liquid pool fires. Fire Saf J 33(3):185–21210.1016/S0379-7112(99)00028-4 ↗
27. Sikanen T, Vaari J, Hostikka S et al (2014) Modeling and simulation of high pressure water mist systems. Fire Technol 50(3):483–50410.1007/s10694-013-0335-8 ↗
28. Yu HZ, Kasiski R, Daelhousen M (2015) Characterization of twin-fluid (water mist and inert gas) fire extinguishing systems by testing and modeling. Fire Technol 51:923–95010.1007/s10694-014-0428-z ↗
29. Wang Z, Wang W, Wang Q (2016) Optimization of water mist droplet size by using CFD modeling for fire suppressions. J Loss Prev Process Ind 44:626–63210.1016/j.jlp.2016.04.010 ↗
30. Shih TH, Liou WW, Shabbir A et al (1995) A new k-ε Eddy-Viscosity Model for high reynolds number turbulent flows. Comput Fluids 24(3):227–23810.1016/0045-7930(94)00032-T ↗
31. Schmidt DP, Nouar I, Senecal PK et al (1999) Pressure-swirl atomization in the near field. In: Sae International Congress & Exhibition. Detroit10.4271/1999-01-0496 ↗
32. O’Rourke PJ, Amsden AA (1987) The TAB method for numerical calculation of spray drop breakup. Available at https://www.sae.org/publications/technical-papers/content/872089/10.4271/872089 ↗
33. O’Rourke PJ (1981) Collective drop effects on vaporizing liquid sprays. Princeton University, New Jersey
34. Liu AB, Mather D, Reitz RD (1993) Modeling the effects of drop drag and breakup on fuel sprays. In: SAE Technical Paper 93007210.4271/930072 ↗
35. Longmire P (2007) Computational fluid dynamics (CFD) simulations of aerosol in a U-shaped steam generator tube. Texas A&M University, Texas
36. Lam C (2015) Statistical analyses of historical pipeline incident data with application to the risk assessment of onshore natural gas transmission pipelines. Western University, London
37. Wang H, Duncan IJ (2014) Likelihood, causes, and consequences of focused leakage and rupture of US natural gas transmission pipelines. J Loss Prev Process Ind 30:177–18710.1016/j.jlp.2014.05.009 ↗
38. He M, Zhang G, Hu S et al (2021) Dynamic characteristics of supersonic turbulent free jets from four types of circular nozzles. Int J Nonlinear Sci Numer Simul. https://doi.org/10.1515/ijnsns-2020-007110.1515/ijnsns-2020-0071 ↗
39. Beji T, Zadeh SE, Maragkos G et al (2017) Influence of the particle injection rate, droplet size distribution and volume flux angular distribution on the results and computational time of water spray CFD simulations. Fire Saf J 91:586–59510.1016/j.firesaf.2017.03.040 ↗