journal article·2012-07

Fire Behaviour of Tropical and European Wood and Fire Resistance of Fire Doors Made of this Wood

Erich Hugi, Regina Weber

Fire Technology· Volume 48· Issue 3
Publisher page

Abstract

In the building industry, there is currently a significant lack of information on fire resistance properties of room separation elements made of tropical wood species. The objective of the present study is to fill this gap by investigating the fire behaviour of tropical wood species and subsequently assessing the fire resistance of elements made of this material. In particular, the prime target was to find easy to measure parameters which correlate with both the charring rate and the deflection, the latter caused by fire induced rapid dehumidification. Further, the so found parameters have been investigated for suitability as reliable predictors for fire resistance of fire doors when tropical wood is used as substitute for European native wood. A series of measurements were carried out for tropical and European wood species. Beam deflection and charring rate as well as the fire resistance of doors were measured in standard fire (ISO 834-1). In addition, the oxygen permeability index (OPI) of wood, which appears to have a strong correlation with the charring rate, was measured. It is shown that in consideration of fire resistance both the charring rate and the deflection have to be addressed when tropical wood is used as substitute for European native wood. Finally, it is clearly confirmed that a single parameter such as wood density is not reliable to assess the substitution of an alternative wood species for a species on which fire resistance test results are available.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Wood Treatment and Properties · Natural Fiber Reinforced Composites · Lignin and Wood Chemistry

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (22)

Show source-provided references
1. State Secretariat for Economic Affairs (SECO) (2007) Sustainable trade with tropical wood: fighting poverty and preservation of tropical forest; in German
2. Swiss Foundation for Development and International Cooperation IC (2004) Agreement between the Swiss Association of Door Manufacturers (VST), Greenpeace Switzerland and World Wide Fund for Nature (WWF) Switzerland concerning the procuring of timber and timber products; in German
3. Swiss Foundation for Development and International Cooperation IC (2004) Action plan of the agreement between the Swiss Association of Door Manufacturers (VST), Greenpeace Switzerland and World Wide Fund for Nature (WWF) Switzerland concerning the procuring of timber and timber products; in German
4. SIA/Lignum (1997) Fire safety for multi story buildings. SIA Documentation 83, Zurich; in German
5. European Standard EN 1363-1 (1999) Fire resistance tests. Part 1. General requirements
6. European Standard EN 1634-1 (2008) Fire resistance and smoke control tests for door, shutter and openable window assemblies and elements of building hardware. Part 1. Fire resistance tests for doors, shutters and openable windows
7. Babrauskas V (2005) Charring rate of wood as a tool for fire investigations. Fire Safety J 40: 528-55410.1016/j.firesaf.2005.05.006 ↗
8. European Standard EN 1995-1-2: 2004 + AC (2006) Eurocode 5: design of timber structures. Part 1–2. General-structural fire design
9. Njankouo JM, Dotreppe JC, Franssen JM (2005) Fire resistance of timbers from tropical countries and comparison of experimental charring rates with various models. Construction and Building Materials 19: 376-38610.1016/j.conbuildmat.2004.07.009 ↗
10. Australian Standard AS 1720.4 (2006) Timber structures. Part 4. Fire resistance for structural adequacy of timber members. Standards Australia, North Sydney, Australia
11. European Standard prEN 15269-3 (2008) Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware. Part 3. Fire resistance of hinged and pivoted timber doorsets and openable timber framed windows
12. Buchanan AH (2001) Structural design for fire safety. Wiley, p 273
13. Eickner HW (1973) Fire resistance of solid-core wood flush doors. For Prod J 23: 38–43
14. Schaffer EL (1967) Charring rate of selected woods-transverse to grain. U.S. Forest Service Research Paper FPL 69, pp 1–22
15. Resch H, Ecklund BA (1964) Permeability of wood. For Prod J May:199–206
16. White RH, Schaffer EL (1981) Transient moisture gradient in fire-exposed wood slab. Wood and Fibre 13(1): 17–38
17. Wagenführ R (2007) Holzatlas. Fachbuchverlag Leipzig im Carl Hanser Verlag, p 816
18. European Standard EN 408 (2003) Timber structures—structural timber and glued laminated timber—determination of some physical and mechanical properties
19. International standard ISO 834-1 (1999) Fire-resistance tests—Elements of building construction—Part 1: General requirements. International Organization for Standardization, Geneva
20. Beushausen HD, Alexander MG, Mackechnie J (2003) Concrete durability specifications in an international context. BFT Concrete. Plant Precast Technol 7:22–32
21. Hugi E, Wuersch M, Risi W, Ghazi Wakili K (2007) Correlation between charring rate and oxygen permeability for 12 different wood species. Journal of Wood Sciences 53: 71–7510.1007/s10086-006-0816-1 ↗