Abstract
The objective of this work is to investigate the effect of the heating rate on the thermal breakage and fallout behavior of the tempered glass with down-flow- ing water film. The heating rate of the glass panes was controlled by changing the distance between the fire source and the glazing surface, which ranged from 0.6 Cs -1 to 1.0 Cs -1 . N-heptane pool fire was adopted to heat up the glass panes and the fuel pan was positioned 500 or 600 mm away from the exposed glass surface. During the experiments the water film was initiated manually when the maximum glazing tem- perature reached different designed values. The results show that all the glazing panes kept their integrity when the fire source distance was 500 mm. In contrast, all the glass panes cracked and fell out the frame when the fire source distance was 600 mm except the one with the water film discharged at 200C. The results illustrate that the heating rate plays a key role on the breakage of glass facades. Under the effect of water film or sprinkler system, glass panes are more likely to fail when exposed to a fire with smaller heat release rate or greater distance, rather than the opposite case.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire dynamics and safety research · Structural Analysis of Composite Materials · Wind and Air Flow Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. Xie Q, Zhang H, Si D (2011) Experimental study on critical breakage stress of float glass with different thicknesses under conditions with temperatures of 25 and 200°C. Fire Mater 35:275–28310.1002/fam.1052 ↗
2. Wang Y, Wang Q, Sun J (2013) Simulating the thermal response of glass under various shading conditions in a fire. Procedia Eng 62:702–70910.1016/j.proeng.2013.08.116 ↗
3. Wang QS, Zhang Y, Wang Y, Sun JH, He LH (2012) Dynamic three-dimensional stress prediction of window glass under thermal loading. Int J Therm Sci 59:152–16010.1016/j.ijthermalsci.2012.03.018 ↗
4. Zhang Y, Wang QS, Zhu XB, Huang XJ, Sun JH (2011) Experimental study on crack of float glass with different thicknesses exposed to radiant heating. Procedia Eng 11:710–71810.1016/j.proeng.2011.04.642 ↗
5. Klassen MS, Sutula JA, Holton MM, Roby RJ (2010) Transmission through and breakage of single and multi-pane glazing due to radiant exposure: state of research. Fire Technol 46:821–832. doi: 10.1007/s10694-010-0150-410.1007/s10694-010-0150-4 ↗
6. Chow WK, Gao Y (2008) Thermal stresses on window glasses upon heating. Constr Build Mater 22:2157–216410.1016/j.conbuildmat.2007.09.004 ↗
7. Klassen MS, Sutula JA, Holton MM, Roby RJ, Izbicki T (2006) Transmission through and breakage of multi-pane glazing due to radiant exposure. Fire Technol 42:79–10710.1007/s10694-006-7254-x ↗
8. Shields T, Silcock G, Hassani S (1998) The behavior of single glazing in an enclosure fire. J Appl Fire Sci 7:145–16310.2190/PJJ7-Y1AH-1QML-RVTA ↗
9. Keski-Rahkonen O (1988) Breaking of window glass close to fire. Fire Mater 12:61–6910.1002/fam.810120204 ↗
10. Joshi AA, Pagni PJ (1994) Fire induced thermal fields in window glass (II-experiments). Fire Saf J 22:45–6510.1016/0379-7112(94)90051-5 ↗
11. Joshi AA, Pagni PJ (1994) Fire induced thermal fields in window glass (I-theory). Fire Saf J 22:25–4310.1016/0379-7112(94)90050-7 ↗
12. Wu CW, Lin TH (2007) Full-scale evaluations on heat resistance of glass panes incorporated with water film or sprinkler in a room fire. Build Environ 42:3277–328410.1016/j.buildenv.2006.08.017 ↗
13. Wu CW, Lin TH, Lei MY, Chung TH, Huang CC, Chiang WT (2005) Fire test on a non-heat-resistant fireproof glass with down-flowing water film. Fire Safety Sci 8:327–33810.3801/IAFSS.FSS.8-327 ↗
14. Wu CW, Lin TH, Lei MY, Chung TH, Huang CC, Chiang WT (2008) Fire resistance tests of a glass pane with down-flowing water film. J Chin Inst Eng 31:737–74410.1080/02533839.2008.9671428 ↗
15. Chen HT, Lee SK (2010) Estimation of heat-transfer characteristics on the hot surface of glass pane with down-flowing water film. Build Environ 45:2089–209910.1016/j.buildenv.2010.03.005 ↗
16. Kim AK, Taber BC, Lougheed GD (1998) Sprinkler protection of exterior glazing. Fire Technol 34:116–138. doi: 10.1023/A:101532541866610.1023/A:1015325418666 ↗
17. Kim AK, Lougheed GD (1997) Fire protection of windows using sprinklers. Constr Technol Update 12:4–10
18. Kim AK (1993) Protection of glazing in fire separations by sprinklers. In: Paper presented at the Sixth International Fire Conference, Oxford, pp. 83–93
19. Kim AK, Lougheed GD (1990) The protection of glazing systems with dedicated sprinklers. J Fire Prot Eng 2:49–5910.1177/104239159000200202 ↗
20. Beason D (1986) Fire endurance of sprinklered glass walls. Fire J 7:43–45
21. Richardson JK, Oleszkiewicz I (1987) Fire tests on window assemblies protected by automatic sprinklers. Fire Technol 23:115–132. doi: 10.1007/BF0104042710.1007/BF01040427 ↗
22. Ng MY, Chow WK (2002) Review on the design and scientific aspects for drencher systems in different countries. Archit Sci Rev 45:323–33510.1080/00038628.2002.9696948 ↗
23. Shao G, Wang Q, Zhao H, Wang Y, Chen H, Su Y, Sun J, He L (2014) Maximum temperature to withstand water film for tempered glass exposed to fire. Constr Build Mater 57:15–2310.1016/j.conbuildmat.2014.01.094 ↗
24. Hu LH (2006) Studies on thermal physics of smoke movement in tunnel fires. PhD Dissertation, University of Science and Technology of China, Hefei, Anhui, China
25. Code for Safety to Life from Fires in Building and Structures. NFPA 101-1981. Section 6-2. National Fire Protection Association, Boston
26. Shields TJ, Silcock GWH, Flood MF (2001) Performance of a single glazing assembly exposed to enclosure corner fires of increasing severity. Fire Mater 25:123–15210.1002/fam.764 ↗
27. Harada K, Enomoto A, Uede K, Wakamatsu T (2000) An experimental study on glass cracking and fallout by radiant heat exposure. In: Paper presented at the Fire Safety Science-Proceedings of the Sixth International Symposium10.3801/IAFSS.FSS.6-1063 ↗