Door Messaging Strategies: Implications for Detection and Notification
Source abstract
Abstract
There are currently efforts to inform the public of the fire safety benefits of keeping bedroom doors closed when occupants are sleeping. A closed door can provide a substantial advantage to sleeping occupants of a bedroom in the event of a fire by hindering the spread of heat and toxic gases. The overall benefit in this arrangement is clear when occupants have interconnected smoke alarms inside and outside the sleeping areas as detection and notification of the fire is not hindered by a closed door. Concerns have arisen for situations when such a detection and notification arrangement is not present in the residence and the door can act as an obstacle for rapid detection and notification of occupants. Calculations and data from the fire science literature were used to evaluate the effect of a closed bedroom door on the number of unsuccessful evacuation outcomes that may result from fires originating in the bedroom, as well as the effect of a closed bedroom door on the audibility of smoke alarms for fires originating elsewhere in the residence. This was combined with statistics on smoke alarm coverage, residential fires, and fatalities to quantify the unsuccessful evacuation outcomes. These results were compared with the number of fire fatalities where a closed bedroom door could offer a benefit. Overall, it was found that the number of unsuccessful evacuation outcomes from a closed bedroom door were relatively small and that the potential benefit of closing a bedroom door was far greater. The analysis concludes that on a purely technical basis, closing the bedroom door at night will save lives and provides a net benefit to the public.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Evacuation and Crowd Dynamics · Fire dynamics and safety research · Injury Epidemiology and Prevention
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (40)
Show source-provided references
1. NFPA Educational Messages Advisory Committee, NFPA position statement: the sleeping room door: open or closed? April 20, 2016
2. Bukowski RW, Peacock RD, Averill JD, Cleary TG, Bryner NP, Walton WD, Reneke PA, Kuligowski ED (2008) Performance of home smoke alarms: analysis of the response of several available technologies in residential fire settings. NIST Technical Note 1455-1, February 2008 revision10.6028/NIST.TN.1455-1r2008 ↗
3. UL Firefighter Safety Research Institute (2018a) https://firstresponders.closeyourdoor.org/. Retrieved March 15, 2019
4. Kerber S, Regan JW, Horn GP, Fent KW, Smith D (2019) Effect of firefighting intervention on occupant tenability during a residential fire. Fire Technol 55(6):2289–2316.10.1007/s10694-019-00864-2 ↗
5. Kerber S (2010) Impact of ventilation on fire behavior in legacy and contemporary residential construction, UL Report
6. Madrzykowski D, Weinschenk C (2018) Understanding and fighting basement fires, UL FSRI Report10.54206/102376/ETSA5492 ↗
7. Traina N, Horn GP, Kerber S, Kyritsis DC, Horn GP (2017) Occupant tenability in single family homes: part I—impact of structure type, fire location and interior doors prior to fire department arrival. Fire Technol 53(4):1589–1610.10.1007/s10694-017-0651-5 ↗
8. Olenick SM, Boehmer H, Klassen MS (2019) Door messaging strategies: implications for detection and notification. NFPA Fire Protection Research Foundation report FPRF-2019-12. October 2019. https://www.nfpa.org/News-and-Research/Data-research-and-tools/Detection-and-Signaling/Door-Messaging-Strategies-Implications-for-Detection-and-Notification.10.1007/s10694-020-01049-y ↗
9. National Fire Protection Association (NFPA) 72, the National Fire Alarm and Signaling Code, National Fire Protection Association, 2019 edition.
10. NFPA (2019a) “CodeFinder”. https://codefinder.nfpa.org/?country=United%20States%20of%20America&fire=true&nfpanumber=72. Accessed on 11 March, 2019.
11. International Code Council (2009) International Building Code, 2009 edition
12. Greene MA, Andres C (2009) 2004–2005 National sample survey of unreported residential fires. United States Consumer Product Safety Commission (CPSC)
13. Harris Poll National Quorum (2010) National fire protection association—smoke alarms
14. NFPA (2010) When it comes to smoke alarms NFPA survey shows American homes still have much room for improvement, Press release. https://www.nfpa.org/News-and-Research/News-and-media/Press-Room/News-releases/2010/When-it-comes-to-smoke-alarms-NFPA-survey-shows-American-homes-still-have-much-room-for-improvement. Accessed 8 October 2010
15. Ahrens M (2019) Smoke alarms in U.S. home fires. National Fire Protection Association
16. Ahrens M (2018) Home structure fires. National Fire Protection Association
17. Fire & Rescue New South Wales (FRNSW) (2017) Smoke alarms in homes: stage 2. Fire Research Report
18. Su JZ, Crampton GP, Carpenter DW, McCartney C, Leroux P (2003) Kemano fire studies—Part 1: response of residential smoke alarms. Research Report 108. National Research Council of Canada
19. National Fire Protection Association (NFPA) (2008) Task group report. Minimum performance requirements for smoke alarm detection technology
20. National Fire Protection Association (NFPA) (2009) Task group on smoke detection follow-up report
21. Bukowski RW, Waterman TE, Christian WJ (1975) Detector sensitivity and siting requirements for dwellings. NIST GCR 75-51, National Institute of Standards and Technology.
22. Harpe SW, Waterman TE, Christian WJ (1977) Detector sensitivity and siting requirements—Phase 2, NBS GCR 77-82, National Institute of Standards and Technology.
23. ISO Standard 13571. Life-threatening components of fire—guidelines for the estimation of time available for escape using fire data. 2007 edition.
24. Halliwell RE, Sultan MA (1986) Attenuation of smoke detector alarm signals in residential buildings. In: Proceedings of the first international symposium of fire safety science (IAFSS)10.3801/IAFSS.FSS.1-689 ↗
25. Butler H, Bowyer A, Kew J (1981) Locating fire alarm sounders for audibility. Building services research and information association. Application Guide 1/81
26. Schifiliti RP, Custer RLP, Meacham BJ (2016) Design of detection systems. In: SFPE Handbook, 5th edition10.1007/978-1-4939-2565-0_40 ↗
27. Underwriters Laboratories Standard 217 (2015) Single and multiple station smoke alarms, Seventh edition
28. Housing and Urban Development (2009) Sound transmission class guidance. Noise Notebook – Chapter 4 Supplement
29. Ball M, Bruck D (2004) The effect of alcohol upon response to fire alarm signals in sleeping young adults. In: Proceedings of the third symposium on human behavior in fire
30. Bruck D, Ball M (2005) Sleep and fire: Who is at risk and can the risk be reduced?. In: Proceedings of the eighth international symposium of fire safety science (IAFSS)10.3801/IAFSS.FSS.8-37 ↗
31. Thomas I, Bruck D (2010) Smoke alarms in dwellings: timely activation and effective notification. Victoria University
32. Havey P, Munoz M, Klassen MS, Holton MM, Olenick SM (2018) Variability and error rates in fire alarm audibility measurements and calculations. Fire Technol 4(6):1725–1744.10.1007/s10694-018-0755-6 ↗
33. Bruck D, Thomas I, Ball M (2007) Optimizing fire alarm notification for high risk groups research project. Waking Effectiveness of Alarms (Auditory, Visual, and Tactile) for the Alcohol Impaired. National Fire Protection Association Research Foundation Report
34. Bruck D, Thomas I (2007) Optimizing fire alarm notification for high risk groups research project: waking effectiveness of alarms (Auditory, Visual, and Tactile) for adults who are hard of hearing. National Fire Protection Association Research Foundation Report
35. Ashley A (2007) Waking effectiveness of emergency alerting devices for the hearing able, hard of hearing, and deaf populations. Doctoral Dissertation. University of Maryland
36. Kerber S (2012) Analysis of changing residential fire dynamics and its implications on firefighter operational timeframes. Fire Technol 48(4):865–891.10.1007/s10694-011-0249-2 ↗
37. Jaldell H (2017) How important is the time factor? Saving lives using fire and rescue services. Fire Technol 53(2):695–708.10.1007/s10694-016-0592-4 ↗
38. Buffington T, Ezekoye OA (2019) Statistical analysis of fire department response times and effects on fire outcomes in the United States. Fire Technol 55(6):2369–2393.10.1007/s10694-019-00870-4 ↗
39. Proulx G (2007) Response to fire alarms. Fire Protection Engineering
40. Hutchison V (2019) Door messaging strategies workshop proceedings. Fire Protection Research Foundation