One of the most recent studied components in the connections of a steel structure exposed to elevated temperature is the column panel loaded in shear. A set of three tests were performed to confirm the analytical prediction model at the Czech Technical University in Prague. The model takes into account the distribution of the internal forces in the shear panel affected by the transfer of the forces by bolt rows in tension. Two panels were tested at ambient temperature and four panels at elevated temperature. The gas temperature in the furnace followed the temperature measured during the seventh Cardington large compartment test in 2003. This contribution is focused on the presentation of the experimental results and an analytical prediction model with a component method.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Thermal Analysis in Power Transmission · Icing and De-icing Technologies · Vibration and Dynamic Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (8)
Show source-provided references
1. Jaspart JP (1997) Recent advances in the field of steel joints—column bases and further configurations for beam-to-column joints and beam splices. Universite de Liege, Belgium
2. Buchanan AH (2000) Steel and composite structures. Wiley, New York. ISBN 0-471-89060-X
3. Burgess IW (2007) Connection modelling in fire. Proceedings of COST C26 workshop urban habitat constructions under catastrophic events, Prague, pp 25–34. ISBN 978-80-01-03583-2
4. Simões da Silva L, Santiago A, Vila Real P (2001) A component model for the behaviour of steel joints at elevated temperatures. J Constr Steel Res 57(11):1169–119510.1016/S0143-974X(01)00039-6 ↗
5. Qian ZH (2007) Shear behaviour of steel members and beam-to-column joint under elevated temperarutes. PhD Thesis, Nanyang Technological University, Singapore, pp 102–148
6. EN 1993-1-8 (2005) Eurocode 3: design of steel structures—Part 1–8: general rules—design of joints, CEN, Brussels
7. Wald F, Chladná M, Moore D, Santiago A, Lennon T (2006) Temperature distribution in a full-scale steel framed building subject to a natural fire. Steel Composite Struct 6(2):159–182. ISSN 1229-936710.12989/scs.2006.6.2.159 ↗
8. EN 1993-1-2 (2005) Eurocode 3: design of steel structures—Part 1–2: general rules—structural fire design, CEN, Brussels