journal article·2018-03

Investigation on Mechanical Behavior of I-Section Steel Columns After Elevated Temperature

Yu Chen, Wentao Xie, Shaohua Han, Kai Wang

Fire Technology· Volume 54· Issue 2
Publisher page

Abstract

This paper presents the experimental and numerical investigations on mechanical behavior of I-section steel columns after elevated temperature exposure. A total of twenty-six compression tests were carried out, in which one was under ambient temperature and the other twenty-five were under heating and cooling phase to study the influence of high temperature (400, 550, 700, 850, 1000°C) and high temperature duration (0.5, 1, 1.5, 2, 2.5 h) on mechanical behavior of the specimens. The failure pattern, axial load versus strain relation, axial load versus displacement relation and ultimate strength of the specimens were presented and analyzed. The test results showed that, high temperature duration had limited influence on the ultimate strength and other mechanical behaviors of the specimens, while the ultimate strength decreases with the increase of the maximum temperature the specimens suffered and some other behaviors also changed. The failure pattern of specimens after high temperature did not change compared with that of specimens under ambient temperature. The finite element models that have the same geometry with the test specimens were set up to compare with the test specimens and the results predicted from finite element analysis showed good agreement with that measured in test. Therefore, parametric study was carried out to investigate the influence of different section geometry on the ultimate strength of I-section steel short columns after elevated temperature. A new relationship for the ultimate strength for I-section steel short columns after elevated temperature was developed and proved to be reliable and accurate. What’s more, the effect of slenderness ratio on the stability coefficient of the columns was also investigated in the parametric study.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire effects on concrete materials · Structural Load-Bearing Analysis · Structural Behavior of Reinforced Concrete

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (17)

Show source-provided references
1. Tondini N, Hoang VL, Demonceau JF, Franssen JM (2013) Experimental and numerical investigation of high-strength steel circular columns subjected to fire. J Constr Steel Res 80:57–8110.1016/j.jcsr.2012.09.001 ↗
2. Kervalishvili A, Talvik I (2014) Alternative approach to buckling of square hollow section steel columns in fire. J Constr Steel Res 96:140–15010.1016/j.jcsr.2013.11.018 ↗
3. Yang KC, Yang FC (2015) Fire performance of restrained welded steel box columns. J Constr Steel Res 107:173–18110.1016/j.jcsr.2015.01.019 ↗
4. Fan SG, Ding XF, Sun WJ, Zhang LY, Liu MJ (2016) Experimental investigation on fire resistance of stainless steel columns with square hollow section. Thin Walled Struct 98:196–21110.1016/j.tws.2015.02.003 ↗
5. Feng M, Wang YC, Davies JM (2003) Structural behaviour of cold-formed thin-walled short steel channel columns at elevated temperatures. Part 1: experiments. Thin Walled Struct 41:543–57010.1016/S0263-8231(03)00002-8 ↗
6. Cheng SS, Li LY, Kim B (2015) Buckling analysis of partially protected cold-formed steel channel section columns at elevated temperatures. Fire Saf J 72:7–1510.1016/j.firesaf.2015.02.010 ↗
7. Scullion T, Ali F, Nadjai A (2011) Experimental study on performance of elliptical section steel columns, under hydrocarbon fire. J Constr Steel Res 67:986–99110.1016/j.jcsr.2011.01.010 ↗
8. Yang KC, Lee HH, Chan O (2006) Performance of steel H columns loaded under uniform temperature. J Constr Steel Res 62:262–27010.1016/j.jcsr.2005.07.001 ↗
9. Yang KC, Hsu R (2009) Structural behavior of centrally loaded steel columns at elevated temperature. J Constr Steel Res 65:2062–206810.1016/j.jcsr.2009.06.007 ↗
10. Ragheb WF (2016) Estimating the local buckling capacity of structural steel I-section columns at elevated temperatures. Thin Walled Struct 107:18–2710.1016/j.tws.2016.05.016 ↗
11. Correia AJPM, Rodrigues JPC (2012) Fire resistance of steel columns with restrained thermal elongation. Fire Saf J 50:1–1110.1016/j.firesaf.2011.12.010 ↗
12. Lu J, Liu HB, Chen ZH, Liao XW (2016) Experimental investigation into the post-fire mechanical properties of hot-rolled and cold-formed steels. J Constr Steel Res 121:291–31010.1016/j.jcsr.2016.03.005 ↗
13. Jin M, Zhao JC, Chang J, Zhang DX (2012) Experimental and parametric study on the post-fire behavior of tubular T-joint. J Constr Steel Res 70:93–10010.1016/j.jcsr.2011.07.018 ↗
14. ISO 834 (1999) Fire-resistance tests—elements of building construction—part 1: general requirements. ISO 834-1, International Organization for Standardization, Geneva
15. Tao Z, Ghannam M, Song TY, Han LH (2016) Experimental and numerical investigation of concrete-filled stainless steel columns exposed to fire. J Constr Steel Res 118:120–13410.1016/j.jcsr.2015.11.003 ↗
16. Chinese Code (2002) Metallic materials-tensile testing at ambient temperature. GB/T 228-2002, Beijing, China (in Chinese)
17. ABAQUS (2006) Standard user’s manual, vols 1–3. Version 6.11. Hibbitt, Karlsson and Sorensen, Inc., Version 6.11, USA