Examining the Design of Escape Routes Using Performance-Based Criteria in a Case Study
Source abstract
Abstract
Life safety in buildings is a primary concern of the society in all countries. Means of escape is one of the most important design aspects in building designs. Alternative means of escape is often required for any large room,where the maximum travel distance, the number of occupants, or the total floor area, exceeds the code prescribed limit. Whilst the definition of the alternative means of escape, and the purpose of providing alternative means of escape, are the same for all countries, the criterion to be satisfied as alternative means of escape varies from code to code. This paper examines the actual performance requirement for alternative means of escape, and proposes performance criteria to examine the alternative means of escape. Such an approach can be used in a performance-based fire safety design. This paper further examines situations where means of escape will exist only for a short time, after which the escape route will be affected by fire. A methodology is proposed,and examples are given to illustrate the use.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Evacuation and Crowd Dynamics · Fire dynamics and safety research · Education, Safety, and Science Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (23)
Show source-provided references
1. V.R. Beck, “A Cost-Effective, Decision-Making Model for Building Fire Safety and Protection,” Fire Safety Journal, vol. 12, 1987, pp. 121-138.10.1016/0379-7112(87)90028-2 ↗
2. D. Yung and V.R. Beck, “A Risk-Cost Assessment Model for Evaluation Fire Risks and Protection Costs in Apartment Buildings,” International Symposium on Fire Engineering for Building Structure and Safety, Melbourne, pp. 15-19, November 1989.
3. L. Zhao and V. Beck, “The Definition of Scenarios for the CESARE-Risk Model,” in Proceedings of the Fifth International Symposium on Fire Safety Science, Y. Hasemi, ed., Melbourne, Australia, International Association for Fire Safety Science, March 1997, pp. 655-666.
4. T. Tanaka, I. Hagiwara, and Y. Mimura, “A Consideration of Required Number of Exits in a Room, A Study on the Safety Performance of Exit Provisions Part 1,” 13th Meeting of the UJNR Panel on Fire Research and Safety, March 13–20, 1996, pp. 53-62.
5. DETR, Approved Document B, Fire Safety, The Building Regulation 1991, 2000 Edition, DETR, UK, 2000.
6. NFPA 101, Life Safety Code Handbook, National Fire Protection Association, Seventh Edition, 1995.
7. Code of Practice for the Provision of Means of Escape in Case of Fire, Buildings Department, Hong Kong, June 1996.
8. J.M. Watts, Jr., “Angle of Exit Remoteness,” Fire Technology, vol. 32,no. 1, 1996, pp. 76-82.10.1007/BF01040759 ↗
9. WRA, Fire and Smoke Control in Road Tunnels, PIARC Committee on Road Tunnels, World Road Association, 1998.
10. CIBSE, Guide E Fire Engineering, The Chartered Institution of Building Services Engineers, 1997.
11. H.P. Morgan, B.K. Ghosh, G. Garrad, R. Pamlitschka, J.-C. De Smedt, and L.R. Schoonbaert, “Design Methodologies for Smoke and Heat Exhaust Ventilation,” BRE FRS, London, 1999.
12. Y. He, I. Moore, M. Luo, and V. Beck, “Doorway Carolimetry for Heat Release Rate Measurement in Building Fires,” Combustion Science and Technology, vol. 132, pp. 365-389.10.1080/00102209808952020 ↗
13. T. Alam and P. Beever, “Flashover Fires—An Experimental Program,” CESARE Report 96-003, Centre for Environmental Safety and Risk Engineering, Victoria University of Technology, Melbourne, Australia, October 1996.
14. NFPA 130, “Standard for Fixed Guideway Transit and Passenger Rail Systems,” 2000 Edition, 2000.
15. J. Paul, “Movement of People,” in SFPE Handbook of Fire protection Engineering, section 3 chapter 13, 2nd Edition, SFPE and NFPA, 1995.
16. NFPA 92B, “Guide for Smoke Management Systems in Malls, Atria, and Large Areas,” 1995.
17. V. Babrauskas, “Full Scale Burning Behavior of Upholstered Chairs,” Technical Note 1103, National Bureau of Standards, Washington, 1979.
18. D.L. Simms and P.L. Hinkley, Fire Research Special Report No. 3, Her Majesty's Stationary Office, London, 1963.
19. Thomas F. Barry, “An Introduction to Quantitative Risk Assessment in Chemical Process Industries,” in SFPE Handbook, section 5, chapter 12, Second Edition, 1995.
20. B.G. Vincent, H.C. Kung, and E.E. Hill, “Residential Side Wall Sprinkler Fire Tests with Limited Water Supply,” Fire Science and Technology, vol. 8,no. 2, 1988, pp. 41-53.10.3210/fst.8.41 ↗
21. A.E. Cote, “Highlights of a Field Test of a Retrofit Sprinkler System,” Fire Journal, vol. 77,no. 3, 1983, pp. 93-103.
22. S. Pearce, “Duty Free Shops, Report of Fire Test,” Ove Arup and Partners Hong Kong Limited Report AFG-HK006, Hong Kong, June 1998.
23. BS 5588: Part 10: 1991 Code of Practice for Shopping Complexes. British Standard Institute, 1991.