Analysis of Visual Characteristics of Short-circuited Arc Sites
Source abstract
Abstract
Abstract Identifying the cause of fire at a fire site is an important fire prevention measure to prevent recurrence. In particular, information about molten marks of the copper wire is essential to check whether electric power is being supplied at the fire site. This study aims to analyse the visual characteristics of arc sites formed by a short circuit to identify the molten marks at the fire site. When a short circuit occurs, electromagnetic force is generated by the short circuit current, and the arc repulsion force is generated by the contact arc. In this study, the effects of the forces, which act on the short-circuited melted area, on the formation of copper molten marks were investigated. Copper molten marks formed by a short circuit were experimentally fabricated, and the visual characteristics based on the force that was applied to the melted area were identified and classified based on features. The results showed that the melted area was affected by both the arc repulsion and electromagnetic forces, resulting in the visual differences between the short-circuited arc sites and flame-melted ones, which are affected by gravity and molecular force. These results provide a theoretical basis for discriminating between arc sites formed by a short circuit and flame-melted marks at the fire site. The validity of this study was verified via a comparative analysis using shape and cross-sectional microstructure of molten marks collected at the fire site.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Electrical Fault Detection and Protection · Combustion and Detonation Processes · Electrical Contact Performance and Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (21)
Show source-provided references
1. National Fire Protection Association (2021) NFPA 921: Guide for fire and explosion investigations.
2. Babrauskas V (2021) Electrical fires and explosions. Fire Science Publishers, New York
3. Bureau of alcohol, tobacco, firearms, and explosives, fire research laboratory, technical bulletin 001: visual characteristics of fire melting on copper conductor.
4. Fire Investigation Section of Tokyo Fire Department (1971) Electrical fire cause and identification, p. 17.
5. M. Benfer, D, Gottuk, (2014) Distinguishing between arcing and melting damage in electrical receptacles. Proc Int Symp Fire Investig Sci and Technol.
6. Cameron N (2020) A methodology for the identification and interpretation of damage on electrical wiring. Fire Arson Investig 71(1):22–30
7. Xu L et al (2012) Forces of rails for electromagnetic. Appl Math Model 36(4):1465–1476. https://doi.org/10.1016/j.apm.2011.09.03610.1016/j.apm.2011.09.036 ↗
8. Su CC (2006) Mechanisms for the longitudinal recoil force in railguns based on the electromagnetic force. IEEE Trans Magn 42(9):2193–2195. https://doi.org/10.1109/TMAG.2006.87801010.1109/TMAG.2006.878010 ↗
9. Ternan JG (1985) Equivalence of the Lorentz and Ampere force laws in magnetostatics. J Appl Phys 57:1743–1745. https://doi.org/10.1063/1.33444810.1063/1.334448 ↗
10. Keshtkar A, Khorrami ZJ, Gharib L (2017) Comparison of inductance gradient and electromagnetic force in two types of railguns with two projectiles by finite-element method. IEEE Trans Plasma Sci 45(8):2387–2392. https://doi.org/10.1109/TPS.2017.271635710.1109/TPS.2017.2716357 ↗
11. Sadiku M (2018) Elements of electromagnetics. Oxford University, Oxeford
12. Bizjak M, Kharin S, Nouri H (2002) Influence of vapour pressure on the dynamics of repulsion by contact blow-off. In proceeding of 21st conference electrical contacts, 268–275.
13. Shea JJ, DeVault B, Chien Y (1994) Blow-open forces on double-breaker contacts. IEEE Trans Comp Hybrids Manufact Techol 17(1):32–38. https://doi.org/10.1109/95.29636510.1109/95.296365 ↗
14. Zhou X, Theisen P (1998) Investigation of arcing effects during contact blow open process. In Proceedings of 44th IEEE Holm Conference Electrical Contacts, 100–108.10.1109/HOLM.1998.722434 ↗
15. Weinschenk C, Madrzykowski D, Courtney P (2019) Impact of flashover fire conditions on exposed energized electrical cords/cables. Fire Technol 56:959–991. https://doi.org/10.1007/s10694-019-00915-8X10.1007/s10694-019-00915-8X ↗
16. Lee EP et al (2000) Study on discrimination between primary and secondary molten marks by DAS. Bull Jpn Association Fire Sci Eng 50(1):1–12. https://doi.org/10.11196/kasai.50.1_110.11196/kasai.50.1_1 ↗
17. Lee EP et al (2002) Study on discrimination between primary and secondary molten marks using carbonized residue. Fire Safety J 37:353–368. https://doi.org/10.1016/S0379-7112(01)00064-910.1016/S0379-7112(01)00064-9 ↗
18. Yun W, Xiaoming S (2014) Study on pores distribution laws in secondary short circuited melted beads of copper wires. Procedia Eng 84(2014):887–892. https://doi.org/10.1016/j.proeng.2014.10.51110.1016/j.proeng.2014.10.511 ↗
19. Liu KH, Shih YH, Chen GJ, Chou JM (2015) Microstructural study on molten marks of fire-causing copper wires. Materials 8:3776–3790. https://doi.org/10.3390/ma806377610.3390/ma8063776 ↗
20. Park J, Kang JH, Lee EP et al (2021) New approach to distinguish copper molten marks based on quantitative microstructure analysis using electron backscatter diffraction. Fire Technol 57:1667–1682. https://doi.org/10.1007/s10694-020-01076-910.1007/s10694-020-01076-9 ↗
21. Liu KH et al (2015) Microstructural study on oxygen permeated arc beads. J Nanomater. https://doi.org/10.1155/2015/37386110.1155/2015/373861 ↗