Abstract The cladding system can play a critical role in fire spread, acting as a conduit for flames to reach vulnerable parts of a structure during bushfires. External cladding faces threats such as intense heat, direct flames, and ember attacks, posing substantial risks to building safety. As the largest surface area of homes, cladding significantly influence a building’s resilience to bushfires. This review provides a comprehensive examination of bushfire-resilient building cladding in an Australian context, followed by an exploration of global provisions and guidelines related to bushfires, with a specific focus on cladding materials. The review is structured into three parts. Firstly, it discusses various bushfire mechanisms affecting cladding. Secondly, it examines existing standards and regulations. Finally, it reviews the cladding systems under different bushfire mechanisms. The study aims to achieve several objectives: (i) Understanding the behaviour of cladding systems under different bushfire mechanisms; (ii) Disseminating codes and guidelines to foster scientific discourse and enhance fire safety standards forbushfires; (iii) Highlighting gaps in current codes, existing cladding materials, and assessment processes to stimulate dialogue among future researchers, policymakers, and industry professionals seeking to address the complex challenges posed by bushfire threats in built environment.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fire dynamics and safety research · Combustion and Detonation Processes · Wind and Air Flow Studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (54)

Show source-provided references
1. Davey SM, Sarre A (2020) The 2019/20 black summer bushfires. Taylor & Francis, pp 47–5110.1080/00049158.2020.1769899 ↗
2. Dossi S et al (2022) Relationships between Building features and wildfire damage in california, USA and Pedrógão grande, Portugal. Int J Wildland Fire 32(2):296–31210.1071/WF22095 ↗
3. Strahan K, Whittaker J, Handmer J (2018) Self-evacuation archetypes in Australian bushfire. Int J Disaster Risk Reduct 27:307–31610.1016/j.ijdrr.2017.10.016 ↗
4. Ariyaratne IE, Ariyanayagam A, Mahendran M (2022) Bushfire-resistant lightweight masonry blocks with expanded perlite aggregate. Fire 5(5):13210.3390/fire5050132 ↗
5. Khan N et al (2019) Physics-based simulation of heat load on structures for improving construction standards for bushfire prone areas. Front Mech Eng 5:3510.3389/fmech.2019.00035 ↗
6. Blanchi R, Leonard JE, Leicester RH (2006) Lessons learnt from post-bushfire surveys at the urban interface in Australia. For Ecol Manag 234(1):S13910.1016/j.foreco.2006.08.184 ↗
7. Terrei L et al (2023) Experimental study of the large scale flammability of wood cladding at the wildland-urban interface. Fire Saf J 141:10399610.1016/j.firesaf.2023.103996 ↗
8. Syphard AD, Brennan TJ, Keeley JE (2017) The importance of Building construction materials relative to other factors affecting structure survival during wildfire. Int J Disaster Risk Reduct 21:140–14710.1016/j.ijdrr.2016.11.011 ↗
9. Hendawitharana S, Ariyanayagam A, Mahendran M (2023) Predicting the behaviour of external steel walls under bushfire radiant heat conditions. Fire Saf J 141:10388810.1016/j.firesaf.2023.103888 ↗
10. Hendawitharana S et al (2023) Bushfire resistance of external light steel wall systems lined with fibre cement boards. Fire Saf J 139:10380610.1016/j.firesaf.2023.103806 ↗
11. AS 3959 (2018) Construction of buildings in bushfire-prone areas. Standards Australia
12. AS 1530.8.1 (2018) Methods for fire tests on building materials, components and structures, Part 8.1: Tests on elements of construction for buildings exposed to simulated bushfire attack — Radiant heat and small flaming sources
13. AS 1530.8.2 (2018) Methods for fire tests on building materials, components and structures, Part 8.2: Tests on elements of construction for buildings exposed to simulated bushfire attack — Large flaming sources
14. Manzello SL (2024) Progress to develop globally harmonized international testing standards for large outdoor fires, including Wildland-Urban interface fires. Fire and Materials10.1002/fam.3258 ↗
15. ISO/TR 24188 (2025) Large outdoor fires and the built environment — Global overview of different approaches to standardization. 2025
16. ISO 6021 (2024), Standard Firebrand Generator.
17. ABCB (2020) Fire performance of external walls and cladding-Advisory Note 2020.2. 3
18. Hossain MD et al (2021) Flame behaviour, fire hazard and fire testing approach for lightweight composite claddings–a review. J Struct Fire Eng 12(3):257–29210.1108/JSFE-09-2020-0027 ↗
19. Penman T et al (2022) Improved accuracy of wildfire simulations using fuel hazard estimates based on environmental data. J Environ Manage 301:11378910.1016/j.jenvman.2021.113789 ↗
20. ISO 13943 (2023), Fire safety- Vocabulary.
21. Ariyaratne IE, Ariyanayagam A, Mahendran M (2022) Diatomaceous Earth aggregates based composite masonry blocks for bushfire resistance. J Struct Fire Eng 13(1):118–14110.1108/JSFE-07-2021-0047 ↗
22. Ariyaratne IE, Ariyanayagam A, Mahendran M (2023) Bushfire resistance of lightweight masonry blocks made with diatomite aggregate. J Mater Civ Eng 35(6):0402310510.1061/JMCEE7.MTENG-15012 ↗
23. Wang H (2006) Ember attack: its role in the destruction of houses during ACT bushfire in 2003. Royal Society of Queensland
24. Blanchi R, Leonard J, Leicester RH (2006) Bushfire risk at the rural/urban interface. in Australasian Bushfire Conference
25. Lautenberger C, Fernandez-Pello A (2009) Spotting ignition of fuel beds by firebrands. WIT Trans Modelling Simul 48:603–61210.2495/CMEM090541 ↗
26. Suzuki S, Manzello SL, Hayashi Y (2013) The size and mass distribution of firebrands collected from ignited Building components exposed to wind. Proc Combust Inst 34(2):2479–248510.1016/j.proci.2012.06.061 ↗
27. Watson K et al (2018) Assessing the bushfire risks for different classes of buildings. in Australian Structural Engineering Conference (: Adelaide, SA). 2018. Engineers Australia Barton, ACT
28. Koo E et al (2010) Firebrands and spotting ignition in large-scale fires. Int J Wildland Fire 19(7):818–84310.1071/WF07119 ↗
29. NFPA 1140 (2022) Standard for Wildland Fire Protection
30. Nguyen D, Kaye N (2021) Experimental and computational modeling of ember hot-spots on roofs during wildland fires.
31. Mell WE et al (2010) The wildland–urban interface fire problem–current approaches and research needs. Int J Wildland Fire 19(2):238–25110.1071/WF07131 ↗
32. Kwok K, He Y, Douglas G (2012) Bushfire-enhanced wind load on structures. Proc Institution Civil Engineers-Engineering Comput Mech 165(4):253–26310.1680/eacm.11.00022 ↗
33. He Y et al (2011) Numerical investigation of bushfire-wind interaction and its impact on Building structure. Fire Saf Sci 10:1449–146210.3801/IAFSS.FSS.10-1449 ↗
34. Morandini F, Santoni P, Balbi J (2001) The contribution of radiant heat transfer to laboratory-scale fire spread under the influences of wind and slope. Fire Saf J 36(6):519–54310.1016/S0379-7112(00)00064-3 ↗
35. Storey MA et al (2020) Drivers of long-distance spotting during wildfires in south-eastern Australia. Int J Wildland Fire 29(6):459–47210.1071/WF19124 ↗
36. Manzello SL (2014) Enabling the investigation of structure vulnerabilities to wind-driven firebrand showers in wildland-urban interface (WUI) fires. Fire Saf Sci 11:83–9610.3801/IAFSS.FSS.11-83 ↗
37. Watson K et al (2010) Assessing the bushfire performance of low-rise steel structures using full Scale bushfire flame front simulation. ASEC., Sydney Australia, 2010
38. Cohen JD (2000) Preventing disaster: home ignitability in the wildland-urban interface. J Forest 98(3):15–2110.1093/jof/98.3.15 ↗
39. Cohen JD (2004) Relating flame radiation to home ignition using modeling and experimental crown fires. Can J for Res 34(8):1616–162610.1139/x04-049 ↗
40. Maranghides A, Johnsson EL, Maranghides A (2008) Residential structure separation fire experiments. US Department of Commerce, National Institute of Standards and Technology10.6028/NIST.TN.1600 ↗
41. Nazare S, Leventon I, Davis R (2021) Ignitibility of structural wood products exposed to embers during wildland fires: a review of literature. National Institute of Standards and Technology, Gaithersburg10.6028/NIST.TN.2153 ↗
42. NASH (2021) Standard for steel framed construction in bushfire areas 2021 (NS 300)
43. Service NRF (2019) Planning for bush fire protection
44. SFM12-7A (2016) State fire marshal: Phoenix. AZ, USA,
45. Green A, Cooper P (2022) Bushfire Sprinkler Systems for Increasing Bushfire Resilience of New and Existing Residential Buildings in Phase 1 Final Report
46. AS1530.1 (1994) Methods for fire tests on Building materials, components and structures, part 1: combustibility test for materials. Australia
47. AS/NZS 3837 (1998) Method of test for heat and smoke release rates for materials and products using an oxygen consumption calorimeter
48. NFPA 285 (2019) Standard fire test method for evaluation of fire propagation characteristics of exterior wall assemblies containing combustible components
49. Smolka M et al (2016) Semi-natural test methods to evaluate fire safety of wall claddings: Update. in MATEC web of conferences. EDP Sciences10.1051/matecconf/20164601003 ↗
50. ASTME 84 (2024) Standard Test Method for Surface Burning Characteristics of Building Materials
51. Justin Leonard RB, Lipkin F, Newnham G, Siggins A, Opie K, Culvenor D, Cechet B, Corby N, Thomas C (2009) Giovanna lorenzin, David campbell, and Matthew barwick, Building and land-use planning research after the 7th February 2009 vicorian bushfires preliminary findings. Victorian 2009 bushfire research response. Australia, Bushfire CRC
52. Wakefield T, He Y, Dowling V (2009) An experimental study of solid timber external wall performance under simulated bushfire attack. Build Environ 44(10):2150–215710.1016/j.buildenv.2009.03.005 ↗
53. Macindoe L et al (2007) Fire tests at the interface between timber decks and exterior walls.
54. Nguyen Q et al (2018) Fire resistance of a prefabricated bushfire bunker using aerated concrete panels. Constr Build Mater 174:410–42010.1016/j.conbuildmat.2018.04.065 ↗