journal article·2026-07Open access

Window Frame Failure During Exterior Fire Exposure

Joseph M. Willi, Rebekah L. Schrader, Gavin P. Horn

Fire Technology· Volume 62· Issue 4

Abstract

Structure-to-structure fire spread has been identified as a key factor in the devastating losses from large fire incidents, specifically wildfire-initiated urban conflagrations. Previous research has shown that the propensity for a window to fail in a wildland-urban interface (WUI) fire incident depends on the window frame material and construction. However, the degree to which window frame materials affect their performance in a WUI fire incident is unclear. The objective of the present work is to identify failure mechanisms and rank the relative performance of common window frame materials, which will ultimately provide guidance on window selection in regions susceptible to WUI fire events. Experiments were conducted to investigate the performance of four types of window frame assemblies (vinyl, wood, fiberglass, aluminum) under fire exposures similar to those from a structure fire to an adjacent structure. Window failure events were identified, and the number of occurrences of each event, the time to the occurrence of each event, and heat load (heat flux integrated over time) at each event occurrence were compared between window frame assembly types. Failure mechanisms differed between frame types, and both the design and construction of components within the frame assemblies notably impacted failure. Wood and vinyl frame assemblies were the most vulnerable to failure, having the greatest number of sash failures. Furthermore, all wood frame assemblies ignited. Aluminum frame assemblies performed best and would likely provide the highest level of performance in regions susceptible to WUI fires.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Fire dynamics and safety research · Fire effects on concrete materials · Fire effects on ecosystems

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (39)

Show source-provided references
1. Quarles SL, Gorham DJ (2020) Siding, windows, and glazing. In: Manzello SL (ed) Encyclopedia of wildfires and wildland-urban interface (WUI) Fires. Springer, Cham, pp 1–8. https://doi.org/10.1007/978-3-319-51727-8_8-110.1007/978-3-319-51727-8_8-1 ↗
2. Knapp EE, Valachovic YS, Quarles SL, Johnson NG (2021) Housing arrangement and vegetation factors associated with single-family home survival in the 2018 camp fire, California. Fire Ecol 17:1–19. https://doi.org/10.1186/s42408-021-00117-010.1186/s42408-021-00117-0 ↗
3. Syphard AD, Brennan TJ, Keeley JE (2017) The importance of building construction materials relative to other factors affecting structure survival during wildfire. Int J Disaster Risk Reduct 21:140–147. https://doi.org/10.1016/j.ijdrr.2016.11.01110.1016/j.ijdrr.2016.11.011 ↗
4. Caton SE, Hakes RSP, Gorham DJ, Zhou A, Gollner MJ (2016) Review of pathways for building fire spread in the wildland urban interface part I: exposure conditions. Fire Technol 53(2):429–473. https://doi.org/10.1007/s10694-016-0589-z10.1007/s10694-016-0589-z ↗
5. Ramsey M, Murphy M, Diaz J (2020) The camp fire public report: a summary of the camp fire investigation., Butte County District Attorney, Oroville, California . https://htv-prod-media.s3.amazonaws.com/files/pge-the-camp-fire-public-report-1592448040.pdf . Accessed 20 May 2025
6. Phillips S (2025) The palisades and eaton fires: neighborhood data and potential housing market effects. UCLA: The Ralph and Goldy Lewis Center for Regional Policy Studies. https://escholarship.org/uc/item/1kg4v5v1 . Accessed 20 May 2025
7. Statistics (2025) CAL FIRE . https://www.fire.ca.gov/our-impact/statistics . Accessed 20 May 2025
8. Bueche D, Foley T (2012) Firewise construction: site design & building materials. https://static.colostate.edu/client-files/csfs/pdfs/firewise-construction2012.pdf . Accessed 20 May 2025
9. Bowditch P, Sargeant A, Leonard J, Macindoe L (2006) Window and glazing exposure to laboratory-simulated bushfires. Report to Bushfire CRC, Confidential CMIT Document 205 . https://www.naturalhazards.com.au/crc-collection/downloads/_66d_window_and_glazing_2006-205.pdf . Accessed 20 May 2025
10. Kim AK, Lougheed GD (1990) The protection of glazing systems with dedicated sprinklers. J Fire Protect Eng. https://doi.org/10.1177/10423915900020020210.1177/104239159000200202 ↗
11. Cohen JD, Wilson P (1994) Current results from structure ignition assessment model (SIAM) research. In: Fire management in the wildland/urban interface: sharing solutions, Alberta, Canada, pp 120–131
12. Mowrer F (1998) Window breakage induced by exterior fires. NIST-GCR-98-751, National Institute of Standards and Technology, Gaithersburg, Maryland . https://ntrl.ntis.gov/NTRL/dashboard/searchResults/titleDetail/PB98148208.xhtml . Accessed 20 May 2025
13. Klassen M, Sutula J, Holton M, Roby R (2006) Transmission through and breakage of multi-pane glazing due to radiant exposure. Fire Technol 42:79–107. https://doi.org/10.1007/s10694-006-7254-x10.1007/s10694-006-7254-x ↗
14. Vedrtnam A, Bedon C, Youssef MA, Wamiq M, Sabsabi A, Chaturvedi S (2020) Experimental and numerical structural assessment of transparent and tinted glass during fire exposure. Construct Build Mater 250:118918. https://doi.org/10.1016/j.conbuildmat.2020.11891810.1016/j.conbuildmat.2020.118918 ↗
15. Vedrtnam A, Bedon C, Youssef MA, Chaturvedi S (2021) Effect of non-uniform temperature exposure on the out-of-plane bending performance of ordinary laminated glass panels. Compos Struct 275:114517. https://doi.org/10.1016/j.compstruct.2021.11451710.1016/j.compstruct.2021.114517 ↗
16. Honfi D, Sjöström J, Bedon C, Kozłowski M (2022) Experimental and numerical analysis of thermo-mechanical behaviour of glass panes exposed to radiant heating. Fire 5(4):124. https://doi.org/10.3390/fire504012410.3390/fire5040124 ↗
17. Willi JM, Gorham DJ, Horn GP (2024) Window pane failure during exterior fire exposure. Fire Technol. https://doi.org/10.1007/s10694-024-01656-z10.1007/s10694-024-01656-z ↗
18. Schrader RL, Ni S, Dow NW, Willi JM, DiDomizio MJ, Horn GP (2025) Experimental study of heat transfer through windows exposed to a radiant panel heater. Fire Technol. https://doi.org/10.1007/s10694-024-01685-810.1007/s10694-024-01685-8 ↗
19. Blanchi R, Leonard J (2005) Investigation of bushfire attack mechanisms resulting in house loss in the ACT bushfire 2003. Bushfire CRC Report . https://www.naturalhazards.com.au/crc-collection/downloads/act_bushfire_crc_report.pdf . Accessed 20 May 2025
20. Leonard J, Opie K, Blanchi R, Newnham G, Holland M (2016) Wye river/separation creek post-bushfire building survey findings. Report EP16924, CSIRO Land and Water. https://www.colacotway.vic.gov.au/files/assets/public/v/1/trimfiles/my-property/emergency-management-relief-recovery-council-support-2016-2017/wyesep-connect-published-csiro-post-bushfire-building-survey-findings-report.pdf . Accessed 20 May 2025
21. Kerber S, Alkonis D (2024) Lahaina fire incident analysis report. Fire Safety Research Institute. https://doi.org/10.60752/102376.2685896210.60752/102376.26858962 ↗
22. McArthur NA (1991) The performance of aluminum building products in bushfires. Fire Mater 15(3):117–125. https://doi.org/10.1002/fam.81015030310.1002/fam.810150303 ↗
23. AS 1530.4 (1990) Methods for fire tests on building materials, components, and structures part 4: fire-resistance test of elements of construction, 3rd edn. Standards Australia, Sydney, Australia. Standards Australia
24. Fortet Casabella J (2020) Study of windows vulnerability in the wildland urban interface using CFD tools. B.S. thesis, Universitat Politècnica de Catalunya . https://upcommons.upc.edu/handle/2117/344253 . Accessed 20 May 2025
25. AS 3959 (2018) Construction of Buildings in Bushfire-Prone Areas, 4th edn. Standards Australia, Sydney, Australia. Standards Australia
26. FEMA (2008) Home builder’s guide to construction in wildfire zones. FEMA P-737, Federal Emergency Management Agency. https://defensiblespace.org/wp-content/uploads/2021/01/FEMA_2008_P-737-Home-Builders-Guide-to-Construction-in-Wildfire-Zones.pdf . Accessed 20 May 2025
27. Maranghides A, Link ED, Hawks S, McDougald J, Quarles SL, Gorham DJ, Nazare S (2022) WUI structure/parcel/community fire hazard mitigation methodology. NIST Technical Note 2205, National Institute of Standards and Technology, Gaithersburg, Maryland. https://doi.org/10.6028/NIST.TN.220510.6028/NIST.TN.2205 ↗
28. International Code Council, Inc. (2024) International wildland-urban interface code. International Code Council, Inc
29. Chapter 7A (2022) Materials and construction methods for exterior wildfire exposure. California Building Standards Commission, California Building Standards Commission. Cal. Code Regs., Title 24, Part 2, Volumes 1 and 2
30. NFPA 1140 (2022) Standard for wildland fire protection. National Fire Protection Association, Quincy, Massachusetts. National Fire Protection Association
31. Gorham DJ, Willi JM, Horn GP (2025) Residential exterior wall reaction to post-flashover compartment fires. Fire Mater. https://doi.org/10.1002/fam.327810.1002/fam.3278 ↗
32. Pitts WM, Murthy AV, Ris JL, Filtz J, Nygård K, Smith D, Wetterlund I (2006) Round robin study of total heat flux gauge calibration at fire laboratories. Fire Saf J 41(6):459–475. https://doi.org/10.1016/j.firesaf.2006.04.00410.1016/j.firesaf.2006.04.004 ↗
33. Blevins LG (1999) Behavior of bare and aspirated thermocouples in compartment fires. In: National Heat Transfer Conference, 33rd Proceedings, Albuquerque, New Mexico, pp. 15–17 . https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=916775 . Accessed 20 May 2025
34. Pitts WM, Braun E, Peacock R, Mitler H, Johnson E, Reneke P, Blevins LG (2003) Temperature uncertainties for bare-bead and aspirated thermocouple measurements in fire environments. ASTM Special Technical Publication 1427:3–15 https://doi.org/10.1520/STP10945S10.1520/STP10945S ↗
35. Whittaker J (2020) Stay and defend. In: Manzello, S.L. (ed.) Encyclopedia of wildfires and wildland-urban interface (WUI) Fires, pp 962–970 . https://doi.org/10.1007/978-3-319-52090-2_4910.1007/978-3-319-52090-2_49 ↗
36. NFPA 257 (2022) Standard on fire test for window and glass block assemblies. National Fire Protection Association, Quincy, Massachusetts. National Fire Protection Association
37. UL 9 (2009) Fire tests of window assemblies, 8th edn. ULSE Inc. ULSE Inc
38. ISO 3009:2003 (2003) Fire-resistance tests — elements of building construction — glazed elements, 2nd edn. International Organization for Standardization, Geneva, Switzerland. International Organization for Standardization
39. AS 1530.4:2014 (2014) Methods for fire tests on building materials, components, and structures part 4: fire-resistance test of elements of construction, 6th edn. Standards Australia, Sydney, Australia. Standards Australia