On the Appropriateness of Fire Dynamics Simulator for the Road Tunnel Smoke Control Problem
Source abstract
Abstract
NIST have made publicly available [1], [2], [3] Fire Dynamics Simulator (FDS) simulations of the Memorial Tunnel tests [4], [5]. Those FDS results can be analysed to extract a critical velocity value. That is done here, with comparison to the critical velocities observed and recorded during the Memorial Tunnel tests. The conclusion is that, for the region of interest (HRR above 30 MW), for the Memorial Tunnel cross section without the ceiling, FDS overpredicts critical velocity by 40% or so. The reasons for the overpredictions are not disclosed by the developer, and so it is unclear how the underlying issues will affect tunnel systems different to the Memorial Tunnel. Consequently, from a practitioner’s point of view, FDS is not a reliable tool to accurately assess critical or confinement velocities in road tunnels as long as the underlying problem for the discussed overpredictions are not understood and not demonstrated to be appropriately resolved.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire dynamics and safety research · Evacuation and Crowd Dynamics · Fire effects on concrete materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (23)
Show source-provided references
1. McGrattan K, Hostikka S, Floyd J, McDermott R, Vanella M, Mueller E (2024) NIST special publication 1018-3 sixth edition fire dynamics simulator technical reference guide volume 3: validation, National Institute of Standards and Technology, US, April 8
2. McGrattan K (2022) Github. https://github.com/firemodels/fds/tree/master/Validation/Memorial_Tunnel. Accessed Feb 2025
3. Bilson M (2023) Email with NIST FDS results data files
4. McGrattan K, McDermott R, Vanella M, Mueller E, Hostikka S, Floyd J, Chandan P (2025) NIST Special Publication 1018-3 Sixth Edition Fire Dynamics Simulator Technical Reference Guide Volume 3: Validation. National Institute of Standards and Technology, US
5. McGrattan K (2025) Github. https://github.com/firemodels/out/tree/master/Memorial_Tunnel. Accessed Mar 2025
6. McGrattan K, Bilson M (2023) Modeling longitudinal ventilation in tunnels using Fire Dynamics Simulator. Fire Saf J 141:103982. https://doi.org/10.1016/j.firesaf.2023.10398210.1016/j.firesaf.2023.103982 ↗
7. Beyer M, Stacey C (2022) CFD validation for tunnel smoke control design. In: 11th International Conference Tunnel Safety and Ventilation, Graz. https://doi.org/10.3217/978-3-85125-883-7-0910.3217/978-3-85125-883-7-09 ↗
8. Li Y, Ingason H (2010) Study of critical velocity and backlayering length in longitudinally ventilated tunnel fires. Fire Saf J no. 45:361–37010.1016/j.firesaf.2010.07.003 ↗
9. Stacey C, Beyer M (2020) Critical of critical velocity - an industry practitioner’s perspective. In: 10th International Conference ‘Tunnel Safety and Ventilation’, Virtual Conference Austria, Graz, Austria. https://www.tunnel-graz.at/assets/files/tagungsbaende/2020/13_Stacey_Beyer_Tunnel2020.pdf
10. Stacey C, Beyer M (2020) Recorded talk on Critical of Critical Velocity - An Industry Practitioner’s Perspective., In: 10th International Conference ‘Tunnel Safety and Ventilation’, Virtual Conference Austria, Graz, Austria. https://www.youtube.com/watch?v=-5rTvTnCm1M&ab_channel=StaceyAgnewPtyLtd
11. Beyer M, Stacey C, Dix A (2021) Critical velocity and the significance of the imminent retraction of 2020 NFPA 502’s Annex D critical velocity equations part one. Australian Tunn Soc, https://australiantunnellingsociety.com.au/2021/03/11/critical-velocity-a-cautionary-note-to-practitioners/
12. Shi YS, De Los Rios N, Lopez K (2022) The critical penalty. In: 19th International symposium on aerodynamics, ventilation & fire in tunnels, Brighton, UK. https://isavft.co.uk/isavft-webshop/
13. Shi YS, Bowman I, De Los Rios N, Harvey N, Lopez K, Pelessone L (2023) NFPA 502 critical velocity calculation methodologies and dimensionless heat release rate. In: 10th International symposium on tunnel safety and security, Stavanger. https://ri.diva-portal.org/smash/get/diva2:1805309/FULLTEXT02.pdf
14. Beyer M, Stacey C, Brenn G (2024) A mixed convection model for estimating the critical velocity to prevent smoke backlayering in tunnels. Fire Technol 61:295–342. https://doi.org/10.1007/s10694-024-01607-810.1007/s10694-024-01607-8 ↗
15. Beyer M, Stacey C (2024) Confinement velocity for smoke in tunnels – how to poke a stick at it. In: 12th International Conference Tunnel Safety and Ventilation, Graz
16. Lin P, Xiong Y, Zuo C, Shi J (2021) Verification of Similarity of Scaling Laws in Tunnel Fires with Natural Ventilation. Fire Technol 57:1611–1635. https://doi.org/10.1007/s10694-020-01084-910.1007/s10694-020-01084-9 ↗
17. Grant G, Jagger S, Lea C (1998) Fires in tunnels. Royal Soc 356:2873–2906. https://doi.org/10.1098/rsta.1998.030210.1098/rsta.1998.0302 ↗
18. Bird R, Stewart W, Lightfoot E (2002) Transport Phenomena, 2nd Edition. John Wiley and Sons Inc., New York
19. Beyer M, Stacey C, Brenn G (2025) Further validation of a mixed convection model of tunnel critical velocity against fullscale experimental data. Fire Technol. https://doi.org/10.21203/rs.3.rs-6092275/v110.21203/rs.3.rs-6092275/v1 ↗
20. MTFVTP (1995a) Memorial Tunnel Fire Ventilation Test Program - Comprehensive Test Report. Bechtel/Parsons Brinckerhoff, Boston
21. MTFVTP (1995b) Memorial Tunnel Fire Ventilation Test Program - Memorial Tunnel Test Data Report incl. 9 discs of raw data. Bechtel/Parsons Brinckerhoff, Boston
22. Kile GW, Gonzalez JA (1997) The Memorial Tunnel Fire Ventilation Test Program: The Longitudinal and Natural Tests. ASHRAE Tech Data Bull 13(1):62–74
23. McGrattan K (2025) Github FDS Release Notes. https://github.com/firemodels/fds/wiki/FDS-Release-Notes