journal article·2026-09

Flow Analysis and Engineering Design of Perfluorohexanone Fire-Extinguishing Pipe Networks

WenBin Zhang, Ruiyang Lu, Zhangfeng Huang, Changxing Ren, Fengchen Li, Xin Liu

Fire Technology· Volume 62· Issue 5
Publisher page

Abstract

No abstract is available for this record. The assistant can identify its topic from the title, but cannot infer the study’s results.

Source: Not provided · Quality: missing

Research context

OpenAlex topics: Fire dynamics and safety research · Flame retardant materials and properties · Coal Properties and Utilization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (29)

Show source-provided references
1. Coulombe RG, Rao A (2025) Fires and local labor markets. J Environ Econ Manag 130:10310910.1016/j.jeem.2024.103109 ↗
2. DiNenno PJ, Forssell EW (2016) Clean agent total flooding fire extinguishing systems. In: SFPE handbook of fire protection engineering, 5th edn. Springer, New York, pp 1483–153010.1007/978-1-4939-2565-0_44 ↗
3. Hu X, Kraaijeveld A, Log T (2020) Numerical investigation of the required quantity of inert gas agents in fire suppression systems. Energies 13:123410.3390/en13102536 ↗
4. Fu XC, Chen T, Zhou B et al (2011) Generation of hydrogen fluoride during fire suppression using 2-H-heptafluoropropane. J Combust Sci Technol 17(4):363–367 (in Chinese)
5. Jackson DA, Young CJ, Hurley MD et al (2011) Atmospheric degradation of perfluoro-2-methyl-3-pentanone: photolysis, hydrolysis and hydration. Environ Sci Technol 45(19):8030–803610.1021/es104362g ↗
6. Taniguchi N, Wallington TJ, Hurley MD et al (2003) Atmospheric chemistry of C2F5C(O)CF(CF3)2: photolysis and reaction with Cl atoms, OH radicals, and ozone. J Phys Chem A 107(15):2674–267910.1021/jp0220332 ↗
7. ISO Gaseous fire-extinguishing systems—physical properties and system design—Part 5: FK-5-1-12 extinguishant. International Organization for Standardization, Geneva
8. Pagliaro JL, Linteris GT (2017) Hydrocarbon flame inhibition by C6F12O (Novec 1230): unstretched burning velocity measurements and predictions. Fire Saf J 87:10–1710.1016/j.firesaf.2016.11.002 ↗
9. Gatsonides JG, Andrews GE, Phylaktou HN, Chattaway A (2015) Fluorinated halon replacement agents in explosion inerting. J Loss Prev Process Ind 36:544–55210.1016/j.jlp.2015.03.001 ↗
10. Liu Y, Duan Q, Xu J et al (2020) Experimental study on a novel safety strategy of lithium-ion battery integrating fire suppression and rapid cooling. J Energy Storage 28:10118510.1016/j.est.2019.101185 ↗
11. Perkins RA, Huber ML, Assael MJ (2018) Measurement and correlation of the thermal conductivity of 1,1,1,2,2,4,5,5,5-nonafluoro-4-(trifluoromethyl)-3-pentanone. J Chem Eng Data 63(8):2783–278910.1021/acs.jced.8b00132 ↗
12. Tanaka K (2016) Measurement of pρT properties of 1,1,1,2,2,4,5,5,5-nonafluoro-4-(trifluoromethyl)-3-pentanone in the near-critical and supercritical regions. J Chem Eng Data 61(11):3958–396110.1021/acs.jced.6b00772 ↗
13. Liang XM (2019) A research of secondary corrosion of C6-fluoroketone. Master’s thesis, Nanjing University of Science and Technology (in Chinese)
14. Wen C, Meng X, Huber ML et al (2018) Measurement and correlation of the viscosity of 1,1,1,2,2,4,5,5,5-nonafluoro-4-(trifluoromethyl)-3-pentanone. J Chem Eng Data 63(8):2783–278910.1021/acs.jced.8b00132 ↗
15. Andersson B, Blomqvist P (2011) Experimental study of thermal breakdown products from halogenated extinguishing agents. Fire Saf J 46(3):104–11510.1016/j.firesaf.2010.11.004 ↗
16. Ditch BD (2003) Thermal decomposition products testing with 1,1,1,2,2,4,5,5,5-nonafluoro-4-trifluoromethyl pentan-3-one (C6 F-ketone) during fire extinguishing. Master’s thesis
17. Liu YJ, Duan QL, Xu JJ et al (2018) Experimental study on the efficiency of dodecafluoro-2-methylpentan-3-one on suppressing lithium-ion battery fires. RSC Adv 8(73):42223–4223210.1039/C8RA08908F ↗
18. Chen T, Lu DY, Hu C et al (2015) Measurement of critical extinguishing concentration of dodecafluoro-2-methylpentan-3-one. Fire Sci Technol 34(9):1129–1133 (in Chinese)
19. Chen YG, Jin JQ, Huang J et al (2023) Study on atomization characteristics of perfluorohexanone and water mist by injection pressure. Fire Sci Technol 42(11):1523–1528 (in Chinese)
20. Wang ZY, Huang J, He YH (2023) Numerical simulation of atomization performance of perfluorohexanone fire extinguishing agent. Fire Sci Technol 42(6):816–821 (in Chinese)
21. National Fire Protection Association (NFPA) (2001) Standard on clean agent fire extinguishing systems. NFPA, Quincy
22. Korean Fire Protection Association KFPA 160: Standard for design and installation of clean agent fire extinguishing systems. KFPA, Seoul
23. European Committee for Standardization, EN 15004-7 Fixed firefighting systems—gas extinguishing systems—Part 7: inert gas extinguishing systems. CEN, Brussels
24. Son BS, Kim HW (2007) A study on percent agent in pipe as a criterion to evaluate limitations and performance of gaseous fire extinguishing systems. J Korean Inst Fire Sci Eng 21(4):1–11 (in Korean)
25. Ministry of Construction of the People’s Republic of China (2005) General Administration of Quality Supervision, Inspection and Quarantine, GB 50370 – 2005: Code for design of gas fire extinguishing systems. China Planning, Beijing (in Chinese)
26. Hua WR, Ma ZM (2003) The experiment research and calculating method of pressure loss in piping of HFC-227ea-fire-extinguishing system. Fire Sci Technol 1:42–44 (in Chinese)
27. Niessner H, Codan E (2010) Significance of Truckenbrodt’s energy and momentum coefficients for loss calculation in ramified pipe systems. Proc Appl Math Mech 10(1):449–45010.1002/pamm.201010217 ↗
28. Liu LX, Dong HB, Yang ZM et al (2014) Calculation of pressure of N2 in vessel. Fire Sci Technol 33(4):377–380 (in Chinese)
29. 3M Company (2018) 3M™ Novec™ 1230 Fire Protection Fluid: Technical Data. Technical Data Sheet