journal article·2020

Connection Performance of Mass Plywood Panels

Byrne T. Miyamoto, Arijit Sinha, Ian Morrell

Forest Products Journal· Volume 70· Issue 1
Publisher page

Abstract

Abstract Tall wood buildings have become more prevalent in North America in the past 10 years. Tall wood-frame buildings implement both mass timber construction and products. Mass timber products are wood-based products that can withstand and hold large loads for long durations of time. Mass timber has allowed for large buildings, which consist mainly of wood, to be erected comprising multiple stories. One new mass timber product that has been fashioned is Mass Plywood Panels (MPP). MPP is a veneer-based engineered wood product, which is a massive, large-scale, structural composite lumber–based panel designed for use in building applications as both a vertical and horizontal element. For any new product to be used in the industry with confidence, a thorough investigation of its physical, mechanical, and connection properties is needed. A series of connection tests, such as fastener withdrawal resistance, dowel-bearing strength, lateral resistance, and a component test on a wall-to-floor system were conducted. The lateral resistance test indicated that the current European Yield Models can be used to calculate the yield loads and yield mode of the MPP by using the dowel-bearing strength of plywood. Three different connection configurations were tested in two distinct loading directions—shear and withdrawal. Their performances are evaluated and compared using two existing engineering models—namely, the American Society of Civil Engineers 41-13 tri-linear model and the seismic analysis of wood-frame structures 10-parameter connection model.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Wood Treatment and Properties · Tree Root and Stability Studies · Innovations in Concrete and Construction Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (27)

Show source-provided references
1. American Society of Civil Engineers (ASCE). 2013. Seismic rehabilitation of existing buildings. ASCE 41-13. ASCE, Reston, Virginia.
2. American Wood Council (AWC). 2015. General dowel equations for calculating lateral connection values. AWC, Washington, D.C.
3. American Wood Council (AWC). 2018. National design specification® for wood construction. AWC, Washington, D.C.
4. APA—The Engineered Wood Association. 2018a. Product report. Freres mass plywood panel products. PR-L325. APA, Tacoma, Washington.
5. ASTM International. 2012. Standard test method for mechanical fasteners in wood. ASTM D1761. ASTM International, West Conshohocken, Pennsylvania.
6. ASTM International. 2018. Standard test method for evaluating dowel-bearing strength of wood and wood-base products. ASTM D5764. ASTM International, West Conshohocken, Pennsylvania.
7. Avent, R.R. and M. Alawady (Eds). 1999. Structural Engineering in the 21st Century. American Society of Civil Engineers, Reston, Virginia. pp. 626–630.
8. Ceccotti, A., C. Sandhaas, M. Okabe, M. Yasumura, C. Minowa, and N. Kawai. 2013. SOFIE project—3D shaking table test on a seven-storey full-scale cross-laminated timber building. Earthq. Eng. Struc. Dyn. 42(13):2003–2021.
9. Folz, B. and A. Filiatrault. 2004. Seismic analysis of woodframe structures I: Model formulation. J. Struct. Eng. 130(9):1353–1360.
10. Forest Products Laboratory (FPL). 2010. Wood handbook—Wood as an engineering material. General Technical Report FPL-GTR-190. USDA Forest Service, FPL, Madison, Wisconsin. 508pp.
11. Gavric, I., A. Ceccotti, and M. Fragiacomo. 2011. Experimental cyclic tests on cross-laminated timber panels and typical connections. Presented at the 14th ANIDIS Conference, September 18–22, 2011, Bari, Italy.
12. Hwang, K. and K. Komatsu. 2002. Bearing properties of engineered wood products 1: Effects of dowel diameter and loading direction. J. Wood Sci. 48:295–301.
13. Kent, S. M., R. J. Leichti, D. V. Rosowsky, and J. J. Morrell 2004. Effect of wood decay by Postia placenta on the lateral capacity of nailed oriented strandboard sheathing and Douglas-fir framing members. Wood Fiber Sci. 36(4):560–572.
14. Kramer, A., A. R. Barbosa, and A. Sinha. 2015. Performance of steel energy dissipaters connected to cross-laminated timber wall panels subjected to tension and cyclic loading. ASCE J. Struct. Eng. 142(4):E4015013.DOI:10.1061/(ASCE)ST.1943-541X.000141010.1061/(ASCE)ST.1943-541X.0001410 ↗
15. Krawinkler, H., F. Parisi, L. Ibarra, A. Ayoub, and R. Medina 2001. Development of a testing protocol for wood frame structures. CUREE-Caltech Woodframe Project Report No. W-02. Stanford University, Palo Alto, California.
16. Kremer, P. D. and M. A. Symmons. 2015. Mass timber construction as an alternative to concrete and steel in the Australia building industry: A PESTEL evaluation of the potential. Int. Wood Prod. J. 6(3):138–147.
17. Langlois, J. D., R. Gupta, and T. H. Miller. 2004. Effects of reference displacement and damage accumulation in wood shear walls. J. Struct. Eng. 130(3):470–479.
18. Mahdavifar, V. 2017. Cyclic performance of connections used in hybrid cross-laminated timber. Doctoral dissertation. Oregon State University, Corvallis.
19. Mahdavifar, V., A. R. Barbosa, A. Sinha, L. M. Muszynski, and R. Gupta. 2016. Hysteretic behaviour of metal connectors for hybrid (high- and low-grade mixed species) cross laminated timber. Presented at the 2016 World Conference on Timber Engineering, August 22–25, 2016, Vienna, Austria.
20. Mahdavifar, V., A. R. Barbosa, A. Sinha, L. M. Muszynski, and R. Gupta. 2018. Lateral and withdrawal capacity of fasteners on hybrid cross-laminated timber panels. ASCE J. Mat. Civ. Eng. 30(9). DOI:10.1061/(ASCE)MT.1943-5533.000243210.1061/(ASCE)MT.1943-5533.0002432 ↗
21. Mahdavifar, V., A. R. Barbosa, A. Sinha, L. Muszynski, R. Gupta, and S. Pryor. 2019. Hysteretic response of metal connections on hybrid cross-laminated timber panels. J. Struct. Eng. 145(1):04018237.
22. McKenna, F., G. L. Fenves, and M. H. Scott. 2000. Open system for earthquake engineering simulation. University of California, Berkeley. http://opensees.berkeley.edu. Accessed December 6, 2000.
23. Pei, S., J. van de Lindt, and M. Popovski. 2013. Approximate R-Factor for cross-laminated timber walls in multistory buildings. J. Archit. Eng. 13(19):245–255. DOI:10.1061/(ASCE)AE.1943-5568.000011710.1061/(ASCE)AE.1943-5568.0000117 ↗
24. Rammer, D. R. and S. G. Winistorfer. 2001. Effect of moisture content of dowel-bearing strength. Wood Fiber Sci. 33(1):126–139.
25. Rinaldin, G., C. Amadio, and M. Fragiacomo. 2013. A component approach for the hysteretic behavior of connections in cross-laminated wooden structures. Earthq. Eng. Struct. Dyn. 13(42):2023–2042.
26. Shen, Y., J. Schneider, S. Tesfamariam, S. Stiemer, and Z. Mu. 2013. Hysteresis behavior of bracket connection in cross-laminated-timber shear walls. Construct. Build. Mater. 48:980–991.
27. Wilkinson, T. 1991. Dowel bearing strength. Research Paper FPL-RP-505. USDA Forest Service, Forest Products Laboratory, Madison, Wisconsin.