Potential Use of Deformed Shank Nails as a Solution to Annoying Vibrations in Wood Floor Systems
Source abstract
Abstract
Abstract In the United States, modern designs of wood floor systems rarely directly account for annoying floor vibration criteria, because it is not a required design criterion in the International Building Code or the International Residential Code. However, adhesives are sometimes used to supplement traditional subfloor fasteners in an effort to improve the floor vibration performance, but they are mainly used to reduce or eliminate homebuilder “callbacks” due to floor squeaks. This article addresses using high performance deformed shank fasteners rather than adhesives to minimize common annoying floor vibration problems.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Structural Engineering and Vibration Analysis · Wood Treatment and Properties · Tree Root and Stability Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (26)
Show source-provided references
1. Boise Cascade LLC. 2010. Western engineered wood products specifier guide. Boise Cascade, Boise, Idaho.
2. Chui, Y. H. 1988. Evaluation of vibrational performance of light-weight wooden floors. In:Proceedings of the 1988 International Conference on Timber Engineering, September 19–22, 1988, Seattle. Vol. 1. pp. 102–109.
3. Chui, Y. H. 1994. Vibrational performance of wood floors—Optimization of performance and retrofitting. Wood Design Focus5(3):8–11.
4. Dolan, J. D., T. M. Murray, J. R. Johnson, D. Runte, and B. C.Shue. 1991. Preventing annoying wood floor vibrations. J. Struct. Eng. 125(1):19–24.
5. Duncan, R., S. R. Lewis, and J. D.Dolan. 2012 a. Test evaluation of proprietary fastener performance. CMEC Report 11‐027. Composite Materials and Engineering Center, Washington State University, Pullman.
6. Duncan, R., S. R. Lewis, and J. D.Dolan. 2012 b. Test evaluation of proprietary fastener performance. CMEC Report 12‐008. Composite Materials and Engineering Center, Washington State University, Pullman.
7. European Committee for Standardization (CEN) 2004. Eurocode 5: Design of timber structures. Part 1‐1: General—Common rules and rules for buildings. CEN, Brussels.
8. Hu, L. J. 1999. Effects of partitions on vibration performance of engineered wood floors. In:Proceedings of the First International RILEM Symposium on Timber Engineering, Stockholm.
9. Hu, L. J.and Y. H.Chui. 2004. Development of a design method to control vibrations induced by normal walking action in wood-based floors. In:Proceedings of the 8th World Conference on Timber Engineering. VolII. pp. 217–222.
10. Hu, L. J., Y. H. Chui, and D. M.Onysko. 2001. Vibration serviceability of timber floors in residential construction. Prog. Struct. Eng. Mater. 3(3):228–237.
11. ICC Evaluation Service (ICC-ES). 2013. ESR-3071—Evaluation report for TetraGrip nails. ICC, Whittier, California.
12. International Code Council (ICC). 2012a. International Building Code. ICC, Country Club Hills, Illinois.
13. International Code Council (ICC). 2012b. International Residential Code. 2012. ICC, Country Club Hills, Illinois.
14. Johnson, J. R. 1994. Vibration acceptability in wood floor systems. MS thesis. Department of Civil Engineering, Virginia Tech, Blacksburg.
15. Kalkert, R. E. 1997. Improving the vibrational performance of wood. PhD dissertation. Department of Civil Engineering, Virginia Tech, Blacksburg.
16. Kalkert, R. E., J. D. Dolan, and F. E.Woeste, 1993. The current status of analysis and design for annoying wooden floor vibrations. Wood Fiber Sci. 25(3):305–314.
17. Murray, T. M. 1991. Acceptability criterion for occupant-induced floor vibrations. AISC Eng. J. 1991(2):62–70.
18. Murray, T. M., D. E. Allen, and E. E.Unger. 1997. Floor vibration due to human activities. Steel design guide series. American Institute of Steel Construction and Canadian Institute of Steel Construction, Chicago.
19. National Building Code of Canada (NBCC). 2010. National Research Council of Canada, Appendix A. NBCC, Ottawa.
20. Ohlsson, S. V. 1988 a. Springiness and human-induced floor vibrations—A design guide. Swedish Council for Building Research, Stockholm.
21. Ohlsson, S. V. 1988 b. A design approach for footstep-induced floor vibration. In:Proceedings of the 1988 International Conference on Timber Engineering, September 19–22, 1988, Seattle. Vol. 1. pp. 722–729.
22. Onysko, D. M. 1985. Serviceability criteria for resident floors based on a field study of consumer response. Project 03‐50‐10‐008. Forintek Canada Corp., Ottawa.
23. Onysko, D. M. 1988 a. Deflection serviceability criteria for residential floors. Project No. 43‐10C-024, CFS No. 17. Forintek Canada Corp., Ottawa.
24. Onysko, D. M. 1988 b. Performance criteria for residential floors based on consumer responses. In:Proceedings of the 1988 International Conference on Timber Engineering, September 19–22, 1988, Seattle. Vol. 1. pp. 736–745.
25. Smith, I.and Y. H.Chui. 1988. Design of light-weight wooden floors to avoid human discomfort. Can. J. Civil Eng. 15:254–262.
26. Woeste, F. E.and J. D.Dolan. 2007. Design to minimize annoying wood-floor vibrations. Struct. Eng. 8(5):24–27.