journal article·2021-05-14Open access

Effects of Titanium Corrosion Products on In Vivo Biological Response: A Basis for the Understanding of Osseointegration Failures Mechanisms

Claudia Cristina Biguetti, Franco Cavalla, Angélica Cristina Fonseca, Andre Petenucci Tabanez, Danyal A. Siddiqui, Sutton E. Wheelis, Rumio Taga, Walid D. Fakhouri, Renato Menezes Silva, Danieli C. Rodrigues, Gustavo Pompermaier Garlet

Abstract

Corrosion resistance is a key feature of titanium biocompatibility. However, Ti surfaces exposed to critical environments (such as, chronic infection and inflammation) can undergo corrosion processes in vivo, leading to an unfavorable biological response and clinical failure, which remains poorly explored. In this study, we characterized an experimental model to replicate the surface features of Ti corrosion process observed within in vivo failures, and the cellular, tissue and molecular events associated with corroded Ti surface implantation into subcutaneous and bone tissue of C57Bl/6 mice. Prior to in vivo implantation, commercially pure Ti Commercially pure titanium and Ti–6Al–4V alloy (Ti64) specimens were exposed to electrochemical polarization in 30% citric acid, while being polarized at 9 V against a saturated calomel electrode for 20 min. The electrochemical attack induced accelerated corrosion on both Ti-based specimens, producing structural and chemical changes on the surface, comparable to changes observed in failed implants. Then, microscopy and molecular parameters for healing and inflammation were investigated following control and corroded Ti implantation in subcutaneous (cpTi disks) and oral osseointegration (Ti64 screws) models at 3, 7, 14 and 21 days. The host response was comparatively evaluated between control and corroded Ti groups by microCT (bone), histology (H&E, histomorphometry, immunostaining and picrosirius red), and real-time PCR array for inflammatory and healings markers. Corroded cpTi disks and Ti64 screws induced a strong foreign body response (FBR) from 3 to 21 days-post implantation, with unremitting chronic inflammatory reaction lasting up to 21 days in both subcutaneous and osseointegration models. In the subcutaneous model, FBR was accompanied by increased amount of blood vessels and their molecular markers, as well as increased TRAP+ foreign body giant cell count. In the osseointegration model, failures were identified by an osteolytic reaction/bone loss detected by microCT and histological analyses. The corroded devices were associated with a dominant M1-type response, while controls showed transient inflammation, an M2-type response, and suitable healing and osseointegration. In conclusion, corrosion of Ti-based biomaterials induced exacerbated inflammatory response in both connective tissue and bone, linked to the upregulation of fibrosis, pro-inflammatory and osteoclastic markers and resulted in unfavorable healing and osseointegration outcomes.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (67)

Show source-provided references
1. Advances in Surfaces and Osseointegration in Implantology. Biomimetic Surfaces10.4317/medoral.20353 ↗
2. Osseointegration of Implants—A Biological and Clinical Overview10.1016/b978-0-12-813384-2.00002-3 ↗
3. The Interface Zone of Inorganic implantsIn Vivo: Titanium Implants in Bone10.1007/bf02363944 ↗
4. Osseointegrated Titanium Implants:Requirements for Ensuring a Long-Lasting, Direct Bone-To-Implant Anchorage in Man10.3109/17453678108991776 ↗
5. Diabetes as a Risk Factor for Orthopedic Implant Surface Performance: A Retrieval and In Vitro Study10.1007/s40735-021-00486-8 ↗
6. Corrosion and Surface Modification on Biocompatible Metals: A Review10.1016/j.msec.2017.04.102 ↗
7. HGMB1 and RAGE as Essential Components of Ti Osseointegration Process in Mice10.3389/fimmu.2019.00709 ↗
8. Oral Implant Osseointegration Model in C57Bl/6 Mice: Microtomographic, Histological, Histomorphometric and Molecular Characterization10.1590/1678-7757-2017-0601 ↗
9. CCR2 Contributes to F4/80+ Cells Migration along Intramembranous Bone Healing in Maxilla, but its Deficiency Does Not Critically Affect the Healing Outcome10.3389/fimmu.2018.01804 ↗
10. Metal Is Not Inert: Role of Metal Ions Released by Biocorrosion in Aseptic Loosening-Current Concepts10.1002/jbm.a.32625 ↗
11. In vitro evaluation of Cytotoxicity and Corrosion Behavior of Commercially Pure Titanium and Ti-6Al-4V Alloy for Dental Implants10.4103/0972-4052.197936 ↗
12. Association of Global DNA Methylation to Titanium and Peri-Implantitis: A Case-Control Study10.1177/2380084418822831 ↗
13. Understanding Peri-Implant Endosseous Healing10.1002/j.0022-0337.2003.67.8.tb03681.x ↗
14. Potential Causes of Titanium Particle and Ion Release in Implant Dentistry: A Systematic Review10.3390/ijms19113585 ↗
15. Progression of Bio-Tribocorrosion in Implant Dentistry10.3389/fmech.2020.00001 ↗
16. The Histopathology of Different Foreign-Body Reactions in Oral Soft Tissue and Bone Tissue10.1007/bf02358804 ↗
17. Host Response to Titanium Dental Implant Placement Evaluated in a Human Oral Model10.1902/jop.2006.050406 ↗
18. Ionic Liquid Coatings for Titanium Surfaces: Effect of IL Structure on Coating Profile10.1021/acsami.5b09309 ↗
19. Periodontal Disease, Peri-Implant Disease and Levels of Salivary Biomarkers IL-1beta, IL-10, RANK, OPG, MMP-2, TGF-Beta and TNF-Alpha: Follow-Up over 5 Years10.1590/1678-7757-2018-0316 ↗
20. Biological Responses of Human Mesenchymal Stem Cells to Titanium Wear Debris Particles10.1002/jor.22002 ↗
21. Chemokines Associated with Pathologic Responses to Orthopedic Implant Debris10.3389/fendo.2017.00005 ↗
22. Titanium-Tissue Interface Reaction and its Control with Surface Treatment10.3389/fbioe.2019.00170 ↗
23. Interleukin-6 in the Blood of Patients with Total Hip Arthroplasty without Loosening10.1097/00003086-199909000-00018 ↗
24. Institute of Laboratory Animal Resources (U.S.) · 2011
25. Effects of Multiple Implantations of Titanium Healing Abutments: Surface Characteristics and Microbial Colonization10.1016/j.dental.2020.05.016 ↗
26. Titanium Surfaces and Detoxification Procedures: Effects of Bacterial Biofilm and Citric Acid Exposure on Oxide Layer Behavior10.1007/s40735-021-00484-w ↗
27. Surface Spectroscopic Characterization of Titanium Implants after Separation from Plastic-Embedded Tissue10.1016/0142-9612(88)90098-1 ↗
28. Gene Expression Dynamics during Bone Healing and Osseointegration10.1902/jop.2010.100577 ↗
29. Biomaterials: Foreign Bodies or Tuners for the Immune Response?10.3390/ijms20030636 ↗
30. Corrosion of Phosphate-Enriched Titanium Oxide Surface Dental Implants (TiUnite) under In Vitro Inflammatory and Hyperglycemic Conditions10.1002/jbm.b.31548 ↗
31. Corrosion of Machined Titanium Dental Implants under Inflammatory Conditions10.1002/jbm.b.31162 ↗
32. What Is the Impact of Titanium Particles and Biocorrosion on Implant Survival and Complications? A Critical Review10.1111/clr.13305 ↗
33. The Peri-Implantitis: Implant Surfaces, Microstructure, and Physicochemical Aspects10.1111/j.1708-8208.2009.00244.x ↗
34. A Pre-clinical Murine Model of Oral Implant osseointegrationA Pre-clinical Murine Model of Oral Implant Osseointegration10.1016/j.bone.2013.07.021 ↗
35. Mechanical Biocompatibilities of Titanium Alloys for Biomedical Applications10.1016/j.jmbbm.2007.07.001 ↗
36. Biomedical Titanium Alloys with Young’s Moduli Close to that of Cortical Bone10.1093/rb/rbw016 ↗
37. Can Degradation Products Released from Dental Implants Affect Peri‐implant Tissues?10.1111/jre.12479 ↗
38. A Literature Review Study on Atomic Ions Dissolution of Titanium and its Alloys in Implant Dentistry10.3390/ma12030368 ↗
39. Comparison of Metal Release from Various Metallic Biomaterials in vitroComparison of Metal Release from Various Metallic Biomaterials In Vitro10.1016/j.biomaterials.2004.02.005 ↗
40. Oral Mucosa Tissue Response to Titanium Cover Screws10.1902/jop.2011.110392 ↗
41. Systemic and Local Tissue Response to Titanium Corrosion
42. Local Effect of Titanium Implant Corrosion: an Experimental Study in Rats10.1016/j.ijom.2008.05.013 ↗
43. The Response of Macrophages to Titanium Particles Is Determined by Macrophage Polarization10.1016/j.actbio.2013.06.027 ↗
44. Titanium Particles in Tissues from Peri-Implant Mucositis: An Exfoliative Cytology-Based Pilot Study10.4103/jisp.jisp_184_16 ↗
45. Titanium Ions Form Particles that Activate and Execute Interleukin-1β Release from Lipopolysaccharide-Primed Macrophages10.1111/jre.12364 ↗
46. Detoxification of Titanium Implant Surfaces: Evaluation of Surface Morphology and Bone-Forming Cell Compatibility10.1007/s40735-017-0111-2 ↗
47. In Vivosevere Corrosion and Hydrogen Embrittlement of Retrieved Modular Body Titanium Alloy Hip-Implants10.1002/jbm.b.31171 ↗
48. Titanium Corrosion Mechanisms in the Oral Environment: A Retrieval Study10.3390/ma6115258 ↗
49. Implant Biomaterials: A Comprehensive Review10.12998/wjcc.v3.i1.52 ↗
50. Titanium Corrosion: Implications for Dental Implants10.1922/EJPRD_1531Shah10 ↗
51. Titanium Corrosion in Peri-Implantitis10.26226/morressier.5ac3832a2afeeb00097a3e26 ↗
52. How Do Titanium and Ti6Al4V Corrode in Fluoridated Medium as Found in the Oral Cavity? an In Vitro Study10.1016/j.msec.2014.11.055 ↗
53. In Vitro Evaluation of the Effects of Multiple Oral Factors on Dental Implants Surfaces10.1563/aaid-joi-d-15-00165 ↗
54. Multifaceted Roles of Environmental Factors toward Dental Implant Performance: Observations from Clinical Retrievals and In Vitro Testing10.1016/j.dental.2018.08.299 ↗
55. In Vitro Evaluation of Titanium Exfoliation during Simulated Surgical Insertion of Dental Implants10.1563/aaid-joi-d-14-00230 ↗
56. Biomaterial Based Modulation of Macrophage Polarization: a Review and Suggested Design Principles10.1016/j.mattod.2015.01.019 ↗
57. IL-1alpha, IL-1beta and TNF-Alpha Secretion during In Vivo/Ex Vivo Cellular Interactions with Titanium and copperIL-1α, IL-1β and TNF-α Secretion during In Vivo/Ex Vivo Cellular Interactions with Titanium and Copper10.1016/s0142-9612(02)00359-9 ↗
58. Physico-chemical Considerations of Titanium as a Biomaterial10.1016/0267-6605(92)90056-y ↗
59. In vitro and In Vivo Characterization of Antibacterial Activity and Biocompatibility: a Study on Silver-Containing Phosphonate Monolayers on Titanium10.1016/j.actbio.2014.12.020 ↗
60. MMP1-1607 Polymorphism Increases the Risk for Periapical Lesion Development through the Upregulation MMP-1 Expression in Association with Pro-inflammatory Milieu Elements10.1590/1678-775720160112 ↗
61. Intramembranous Bone Healing Process Subsequent to Tooth Extraction in Mice: Micro-computed Tomography, Histomorphometric and Molecular Characterization10.1371/journal.pone.0128021 ↗
62. Release of Titanium Ions from an Implant Surface and Their Effect on Cytokine Production Related to Alveolar Bone resorptionRelease of Titanium Ions from an Implant Surface and Their Effect on Cytokine Production Related to Alveolar Bone Resorption10.1016/j.tox.2014.10.016 ↗
63. IL4/PGE2 Induction of an Enlarged Early Endosomal Compartment in Mouse Macrophages Is Rab5-dependent10.1016/j.yexcr.2006.03.025 ↗
64. Cellular and Molecular Dynamics during Early Oral Osseointegration: A Comprehensive Characterization in the Lewis Rat10.1021/acsbiomaterials.0c01420 ↗
65. Investigation of the Early Healing Response to Dicationic Imidazolium-Based Ionic Liquids: A Biocompatible Coating for Titanium Implants10.1021/acsbiomaterials.9b01884 ↗
66. Effects of Decontamination Solutions on the Surface of Titanium: Investigation of Surface Morphology, Composition, and Roughness10.1111/clr.12545 ↗
67. Surface Characterization of Titanium Implant Healing Abutments before and after Placement10.1111/cid.12566 ↗