journal article·2021-06-21Open access

The Optimization of Ti Gradient Porous Structure Involves the Finite Element Simulation Analysis

Bowen Liu, Wei Xu, Xin Lu, Maryam Tamaddon, Mingying Chen, Jiaqi Dong, Yitong Liu, Lijia Guo, Jiazhen Zhang, Xuanhui Qu, Xinbo He, Chaozong Liu

Abstract

Titanium (Ti) and its alloys are attracting special attention in the field of dentistry and orthopedic bioengineering because of their mechanical adaptability and biological compatibility with the natural bone. The dental implant is subjected to masticatory forces in the oral environment and transfers these forces to the surrounding bone tissue. Therefore, by simulating the mechanical behavior of implants and surrounding bone tissue we can assess the effects of implants on bone growth quite accurately. In this study, dental implants with different gradient pore structures that consisted of simple cubic (structure a), body centered cubic (structure b) and side centered cubic (structure c) were designed, respectively. The strength of the designed gradient porous implant in the oral environment was simulated by three-dimensional finite element simulation technique to assess the mechanical adaptation by the stress-strain distribution within the surrounding bone tissue and by examining the fretting of the implant-bone interface. The results show that the maximum equivalent stress and strain in the surrounding bone tissue increase with the increase of porosity. The stress distribution of the gradient implant with a smaller difference between outer and inner pore structure is more uniform. So, a-b type porous implant exhibited less stress concentration. For a-b structure, when the porosity is between 40 and 47%, the stress and strain of bone tissue are in the range of normal growth. When subject to lingual and buccal stresses, an implant with higher porosity can achieve more uniform stress distribution in the surrounding cancellous bone than that of low porosity implant. Based on the simulated results, to achieve an improved mechanical fixation of the implant, the optimum gradient porous structure parameters should be: average porosity 46% with an inner porosity of 13% (b structure) and outer porosity of 59% (a structure), and outer pore sized 500 μm. With this optimized structure, the bone can achieve optimal ingrowth into the gradient porous structure, thus provide stable mechanical fixation of the implant. The maximum equivalent stress achieved 99 MPa, which is far below the simulation yield strength of 299 MPa.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (22)

Show source-provided references
1. Biomaterials and Biomechanics of Oral and Maxillofacial Implants: Current Status and Future Developments10.1046/j.1365-2591.2000.00269.x ↗
2. Effect of Porous Orthopaedic Implant Material and Structure on Load Sharing with Simulated Bone Ingrowth: A Finite Element Analysis Comparing Titanium and PEEK10.1016/j.jmbbm.2018.01.017 ↗
3. Microstructure and Mechanical Properties of Open-Cell Porous Ti-6Al-4V Fabricated by Selective Laser Melting10.1016/j.jallcom.2017.04.190 ↗
4. Recent Advances in 3D Printing of Biomaterials10.1186/s13036-015-0001-4 ↗
5. A 2003 Update of Bone Physiology and Wolff's Law for Clinicians10.1043/0003-3219(2004)0742.0.CO;2 ↗
6. Porous Titanium Materials with Entangled Wire Structure for Load-Bearing Biomedical Applications10.1016/j.jmbbm.2011.09.016 ↗
7. Fabrication of Graded Porous Titanium-Magnesium Composite for Load-Bearing Biomedicalapplications10.1016/j.matdes.2014.12.001 ↗
8. Biomechanical Analysis of 4 Types of Short Dental Implants in a Resorbed Mandible10.1016/j.prosdent.2018.07.013 ↗
9. Properties of Open-Cell Porous Metals and Alloys for Orthopaedic Applications10.1007/s10856-013-4998-y ↗
10. Mechanical Properties of Optimized Diamond Lattice Structure for Bone Scaffolds Fabricated via Selective Laser Melting10.3390/ma11030374 ↗
11. Mechanical Effect on the Evolution of Bone Formation during Bone Ingrowth into a 3D-Printed Ti-alloy Scaffold10.1016/j.matlet.2020.127921 ↗
12. Mathematical Modeling of Bone In-Growth into Undegradable Porous Periodic Scaffolds under Mechanical Stimulus10.1177/2041731419827167 ↗
13. Design of Patient Specific Dental Implant Using FE Analysis and Computational Intelligence Techniques10.1016/j.asoc.2018.01.025 ↗
14. Novel Adaptive Finite Element Algorithms to Predict Bone Ingrowth in Additive Manufactured Porous Implants10.1016/j.jmbbm.2018.07.019 ↗
15. Finite-Element Analysis of 3 Situations of Trauma in the Human Edentulous Mandible10.1016/j.joms.2014.10.014 ↗
16. Elastic-modulus Enhancement during Room-Temperature Aging and its Suppression in Metastable Ti-Nb-Based Alloys with Low Body-Centered Cubic Phase Stability10.1016/j.actamat.2015.09.030 ↗
17. Effect of Pore Size on Bone Ingrowth into Porous Titanium Implants Fabricated by Additive Manufacturing: An In Vivo experiment10.1016/j.msec.2015.10.069 ↗
18. Implant Micromotion Is Related to Peak Insertion Torque and Bone Density10.1111/j.1600-0501.2008.01679.x ↗
19. Selective Laser Melting Processed Ti6Al4V Lattices with Graded Porosities for Dental Applications10.1016/j.jmbbm.2018.08.047 ↗
20. Wang · 2017
21. Influence of the Structural Orientation on the Mechanical Properties of Selective Laser Melted Ti6Al4V Open-Porous Scaffolds10.1016/j.matdes.2016.01.095 ↗
22. Fatigue Behavior of Porous Biomaterials Manufactured Using Selective Laser Melting10.1016/j.msec.2013.08.006 ↗